Ademco - 1025 Alarm Processing Center

File Preview
File Preview
Click below to download for free

File Data

Name ademco-1025-alarm-processing-center-8734920165.pdf
Type PDF
Size 1.32 MB
Downloads

Text Preview

FADEMCO N IOE PROCESSING INFORMATION No 1025 Alarm Processing Center is a local alarm panel with the following features Supervised Protection Zone for Normal and Fast Acting Perimeter and Interior Devices Zone with 45 or 30 Second Entry and Exit Delay Times Supervised Hour Audible Emergency Panic Circuit Indication of Zone Status A C Power and Alarm Memory indicates alarm has taken place and bell has timed off for Bell s or Electronic Siren s Closure of Dry Contacts and Optional Early Warning Horn Alarm Cut off and Restore and Battery Test Switch Low Voftage Plug in Transformer and Built in Rechargeable Power Supply Turned ON and OFF from a Keyswitch e g No 4235 Remote Station s may be used instead see ACCES at end of these instructions cabinet provides room for optional installation of a digital communicator or other accessories see ACCESSORIES herein No WS669 WS670,678,679 AND WIRING See Figure 1 not connect thebattery or plug in transformer until all other wiring has been completed Use of twisted wiring recommended for all runs for greater immunity to unwanted induced voltage WHITE jumper is provided at the top of the chassis If this jumper is cut it will shorten the factory provided entry delay delay and cut off times as tabulated in Figure 1 Information Protection Zone Double Loop Run a pair of wires from terminals 1 and to all protection points in this zone and return to terminals 4 and 3 respectively protection devices into the two loops as follows Response Loop Basic Protection Zone Connect closed circuit con of normal acting devices such as magnetic contacts foil etc in series with loop Maximum permissible resistance 300 ohms Response Loop Basic Protection Zone Connect closed circuit contacts fast acting devices such as vibration contacts e g No 1 1 glass protection e g No 9 and photoelectric units without built in delays in series with loop permissible resistance 300 ohms To lessen the chance of false alarms fast response loop should not contain exposed metallic contacts An opening in either of those loops or a short between loops will cause an alarm when the system is ON with open circuit contacts such as mats may be connected these loops or into the fast response loop with an Ademco No Mat Coupler Zone Connect closed circuit contacts on the entry exit door as well as contacts or sensors located in the path between the exit door and the con in a series wiring loop across these terminals Maximum permissible loop 300 ohms zone provides entry and exit times of 45 seconds each 30 seconds if the jumper is cut per Fig 1 additional security against shorts the Basic Protection Zone normal loop may be routed along with the entry exit loop as shown in Figure 1 A between these loops when the system is ON will result in an alarm the entry delay interconnections must be made with U L listed limited energy cable STATUS SIG1 ACCESSORY POST 4L J 1 DC 2SAH 24 HR v AC CLASS I3 12V 6VA MAT 1 Field Connections JUMPER CABINET TO COLD WATER PIPE ELECTRICAL TO AVOID POSSIBLE STATIC VOLTAGE DAMAGE permitted plus on alarm is 2A using remote station s lieu of keyswitch con e g Nos 244,245.215 216,22 228.815 816 Optional entry exit of normal security for Panic Switches Connect locking type open circuit emergency such as No 264,266,268 or 269 in parallel across these terminals of an emergency switch at any time system OFF or ON will cause the bell s to ring and the output contacts to close Alarms activated from emer switches do not cut off until the switches are reset 706 Mini Howler Optional Connect as shown in Figure 1 The mini howler sound 1 During the entry delay period 2 In case of accidental closing with entry exit zone open 3 lf an alarm occurs in the entry exit zone while the is ON In this last case the No 706 will sound until the alarm bell cuts off or entry exit loop returns to normal whichever occurs leer When sounding the 706 draws 50 ma 20 STATUS POST RED WITH Connect a keyswitch with key removable in and posi such as No 4235 across these terminals OFF Position Contacts ON Position Contacts OPEN A knockout is provided on the cover of cabinet for mounting If this keyswitch is located remotely it should be kept the protected area remote station s showing system status may be used via an appropriate See ACCESSORIES Dry Contacts These contacts may be used to trip a digital communicator dialer or as desired The contacts close on alarm burglary or emer and open upon bell cut off burglary or when emergency panic switches manually reset The contacts do not close during bell test Rating 2A 28V 1OV AC See CAUTION at end of these instructions DC For Accessories Up to 220 ma continuous load can be connected to terminals for items such as those described in ACCESSORIES During up to 2 amperes total combined load may be supplied by these and the bell terminals 15 and 16 DC Bells or Electronic Sirens having a combined total rating of 2 amperes any alarm load connected to term 14 and 20 may be connected in parallel these terminals If electronic sirens are used observe polarity Except during an emergency panic alarm cut off occurs after approxi 12 minutes 8 minutes if the WHITE jumper is cut per Fig 1 The Memory LED remains lit until the panel is disarmed If the protective are then normal the unit will report any subsequent alarm condition Input 12V AC Turn the keyswitch to its OFF position and connect these the output terminals of the No 1320 Transformer Do not plug in the yet with remote arming disarming station accessories minimum recom load resistance 50K ohms the cabinet to a cold water pipe or electrical box Battery After all other wiring is completed and with the keyswitch dosed connect to the battery when ready to proceed with TESTING CHECKOUT CENTER STATUS Egy DEVICE MFG CO N Y 2 lndica tors TEST AND CHECKOUT these tests after the wiring and connections described in the previous section have been completed keyswitch should still be Off and the standby battery must be connected Plug the transformer into a 1lOV AC outlet that is ON 24 hours a day The A C POWER LED should light CAU DO NOT OPERATE ANY OTHER EQUIPMENT SIMULTANEOUSLY FROM THIS TRANSFORMER DAM TO THE TRANSFORMER AND OR EQUIPMENT OR IMPROPER SYSTEM OPERATION COULD RESULT Observe the Zone Status LEDs Neither will be lit if the protective loops are properly wired and all contacts are set When both Zone Status LEDs are out do the following and observe the appropriate LED light in each case Open the fast response loop momentarily The Basic Zone LED should light while the loop is open Open the normal response loop momentarily The Basic Zone LED should lightagain Open the entry exit loop momentarily The Entry Exit Zone LED should light Short the fast and nonal Short the normal and entry exit loops momentarily The Entr

Related Files