Ademco - 1480 Series Valu-Vaults
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-1480-series-valu-vaults-2415387096.pdf |
---|---|
Type | |
Size | 1.15 MB |
Downloads |
Text Preview
w A MODEL DESIGNATIONS COVER HOUSING No No OF 1 No 4008 ADEMCO SECURITY CAM LOCK S NOT FURNISHED INFORMATION No 1480 Series of Valu Vaults provide easily installed small secure key locked enclosures for the temporary permanent storage of valuables A lists the models that are available embodying various combinations of the following Capacities Vaults with nominal interior dimensions of 5 x 5 x 7 or x 5 x 11 are available Cover Types A cover with an deposit slot or one with no slot may be used Locking Provisions A cover accommodating one or for higher security two locks may be used Mounting Methods The vault as received may be bolted permanently in place to floor wall etc by using an accessory locking No 1489 Valu Vault Bracket itself mounted permanently may be unlocked from the bracket whenever necessary Thus it may be carried to another location for and or replaced with an empty vault Electrical Protection Each vault housing contains mounting holes for the optional installation of a cover switch No 19 for closed circuits No 16 for open circuits and or a vibration No 11 or shock Type 980 or sensor see Diagram Select a location the vault noting the following guidelines place the For increased security an inconspicuous should be selected For example in a home suggested a are closet laundry room attic or basement statistics show that the master bedroom and dining room are target areas for thieves The vault may be installed horizontally or vertically on any sturdy surface such as concrete wood floor metal or shelving If optional electrical protection method wiring entry that will be used should be determined and where appropriate the wire should be run before the is mounted permanently place Wire may be brought into the vault via one of the holes at its rear via the at each comer of the vault bottom plate or via a hole drilled in the vault housing as required Wiring be as inconspicuous as possible Switches and or Isors should not be installed until Step 5 the vault see GENERAL INFORMATION to be connected Mount the vault housing optional No 1489 Valu Vault Bracket the selected Before drilling holes check for existing electrical wiring and water pipes possibly concealed in or floors Installation on Concrete Using existing holes in housing or bracket as a template mark hole locations on concrete to insure proper Using a Ye masonry drill bit drill holes approximately 1 3 e deep Insert Lok Bolt supplied into each hole tapping lightly until all but l 2 of Lok Bolt is in hole Remove nuts and washers from Lok Bolts place vault housing or bracket over bolts replace nuts and wash and tighten until vault housing or bracket is secure Installation on Metal Decking or Shelving 3 g carnage bolts not supplied Insert from the bottom of the decking or shelving and install nuts supplied inside of vault or bracket Installation on Wood Floors x 1 W lag bolts not supplied installed from inside of vault or bracket lf a No 1489 Valu Vautt Bracket was installed Step 3 place the housing in it add a No 4008 Cam Lock to brackets front plate and lock the housing in the bracket see Diagram 2 lf optional electrical protection being installed mount the tamper switch and or vibration or shock sensor the holes provided inside the left wall of the vault housing see Diagram 1 and complete the wiring and con that may have begun in Step 2 If the devices are connected in a supervised protective circuit with end of line resistor the vault should be the end of the circuit and the end of line resistor should be installed inside of the vault for greater Install No 4998 Cam Lock s not supplied on the vault cover If a slotted cover is being used the anti fish included with the cover should be held in place by the lock s as indicated in Diagram 1 Slide the vault cover under the flange at the top of the vault housing and lock it in place to complete the 1481 l 1482 1 SPECIFICATIONS 51 21 14 oCm 6 15.2cm x 5 14 oCm 7 16.5cm x 7 18.4cm x 8 20.3cm 11 27.9cm 5 14 oCm 15.2cm x 11 l 2 29.2cm 5 14 oCm 6 15.2cm x 16.5cm x 7 18.4cm x 12 30.5cm with 1489 with 1489 Valu Vault Bracket in vault housing for mounting Tamper Switch No 16 for open circuit Sensor Sensor 19 for closed circuit 11 980 for Type 970,971 Analyzers 982 for Type 972,973 Monitors THE INSTALLER maintenance and inspection at least annually by the installer and frequent testing by the is vita to continuous satisfactory operation of any alarm system installer should assume the responsibility of developing and offering a regular maintenance to the user as well as acquainting the user with the proper operation and limitations of the system and its component parts Recommendations must be included for a specific program frequent testing at least annually to insure the system proper operation at all times INSTALL LOCK See A A Place lock in hole Position Anti Fish Guard over lock Install and tighten Lock Mounting Nut Place Locking Cam over threaded tenon Install and tighten Cam Retaining Nut EACH COVER A A CONCRETE TEXT RETAINING NUT MOUNTING NUT ARE FOR 19 CLOSED OR 16 OPEN SWITCI No 572 MAY VIA t e REQUIRED MOUNTING OPTIONAL 1489Valu Vault SEE 2 1 TYPICAL INSTALLATION No 1484 2 SHOWN SUPPLIED 1489 1480 2 Fit into at rear of housing 5 Support of vault HOLES 4 LOK BOLTS FOR ON LOCKING DIAGRAM 1 4008 LOCK SUPPLIED k 1489 2 OPTIONAL No 1489 Valu Vault BRACKET MANUFACTURING DIVISION OF PITTWAY CORPORATION en Way Syosset 8 198 2 PIllWAY York 11791