Ademco - 4080 & 4080XL Alarm Logiccenters

File Preview
File Preview
Click below to download for free

File Data

Name ademco-4080-4080xl-alarm-logiccenters-3452781690.pdf
Type PDF
Size 2.51 MB
Downloads

Text Preview

for either a UL certified household commercial a microcomputer panel provides every burglary alarm any prior Ademco control panel The No 4080 is a smaller version of the No 408OXL that of the system The following a Listed household reader in becoming with the panels capabilities NO 408OXL Alarm LogiCenter more features Introduction UL requirements will a sist resistors Six burglary zones an emergency zone and a fire zone all fully supervised wire zones with end of Zone independence on the six burglary zones with automatic bell shut off and subsequent all intact zones Alarm memory by zone Indication maintained Built in opening closing or armed disarmed the system reset supplementary signal capability external Built in siren driver Three position Zone Inputs arming capability via optional keyswitch Digital Keypad Remote Station s keyswitch Arming Disarming stations System Check Reset well as built in No 246 or via No 216 Adapter No Power supply with 6V SAH sealed lead acid non venting rechargeable battery No 498 and plug in Up to 45 hours of standby time dependent upon auxiliary output table General Specifications drawn continuous auxiliary Very high regulated continuous current DC output available for powering auxiliary devices up to 5OOmA at Main Entry Exit Delay Zone 1 a Field Selectable entry delay of l 30 delay 45 seconds or 60 seconds and exit delay of 30,60 maximum delay per U L Std 1023 is 60 seconds or 120 seconds b Accepts open and closed circuit permissible U L Std 1023 for Household Burglary c LED annunciation delay disable zone status and alarm memory d Provision of remoteable area in which Auxiliary Delay Zone 2 a Permits delaying control arming but prior to the entry zone being disturbed covering zone is violated subsequent instance by in who stay behind or who enter via a zone other than the main entry exit zone the panel will alarm in zone status and alarm memory b Accepts open and closed circuit devices c LED annunciation zone status and swingers Fast response option permits Night Zones 3,4 a Accepts open and closed circuit devices b LED annunciation activation of space protection located or the normal entry exit path to from motion detection control minimizes No 11 Vibration Contact or No 9 Glass Sentry alarms memory c Normal of vibration Day Night Zones 5,6 a Optional day trouble annunciation buzzer and optional key switch alarm b Accepts open and closed circuit devices c LED annunciation d Fast slow sounders and lights zone status annunciator CHECK RESET Disturbance panel momentarily option disarmed period sounds To silence buzzer alarm armed period causes zone Fire Zone 7 a 24 hour supervised circuit b Accepts open circuit devices c Trouble STATUS LED and rapidly pulsing buzzer and optional the loop is annun sounder d by rapidly back when condition cleared Silent Emergency or Audible Panic Zone 6 a 24 hour supervised devices c Silent Audible circuit momentary lock in circuit b Accepts open and outputs Built in dual SIOW pulse rapid pulse sound for panic burglary fire distinction super loud siren driver to No 714 into up to 8 siren speakers of the No 713 type Powered by DC from the LogiCenter when A C is present and by 6V DC when operating on standby Of 40 watts output power DPDT Alarm Relay 2 sets of dry contacts one set of which The relay may be used instead as a reversing or Mini modularm used to power a bell if that sounding device is for central station police a permissible Siren and or bell cutoff times are selectable as 10 or 30 minutes or continuous disarmed 30 minutes per U L Std 609 6V DC continuous current output 500 mA maximum load to power auxiliary devices such as space pro products DETECTOR RESET switch DC power output capable of supplying up to 250 mA from the 500 mA available current circuit w smoke detectors A separate arming stations smoke detectors commercial burglary panel provided Opening and Closing signal supplementary output as well as individual zone outputs from all 6 zones and is not ac trouble AC supervision and shunted zone closing outputs The closing signal output until the control signal entry exit delay door is opened and closed The opening signal output disarmed A shunted zone output applicable only if and when a is activated produced produced Built in pre alarm sounder as well as output entry delay if that zone is disturbed while four non delay burglary zones is disturbed or shunted has been shunted or longer to signal a faulted zone s has not been shunted alarm will result sounders optional panel is armed and during as No 706 sounds during one or more of 2 seconds if a avoid alarm a non delay burglary zone s is disturbed during exit an exit delay sound exit buzzer warning system must be turned off immediately AC supervisory LED and buzzer Loss of AC will result the buzzer sounding buzzer on loss of AC can be permanently wire from 01 or terminal B17 This will also suppress and the LED being by connecting Power Note If desired from terminal 03 to DC supplementary Other Features Automatic Bell Test and Subscriber Confidence Signal Selectable During arming the battery only and again bell or siren will 112 second at the end of the exit automatically to indicate proper arming 2 seconds Individual shunt switches foreach of the six burglary zones to provide capability of userzone shunting Quick test feature permits test delay times of entry exit bell 1110 or 1160 of their normal desired intervals Zone terminal strip can be unplugged with zone wiring facilitate and easy replacement board should Information window be necessary cover of cabinet which surrounds the LEDs and zone switches is protected forced entry into the panel physical attack An alarm that already has been tripped will continue attempted this point Automatic Low Battery Cut off prevents deep discharge of battery by cutting off current drain the should voltage below approximately to 5.5 volts DESCRIPTION See Diagram 1 Switches SYSTEM CHECK RESET and ARM DISARM KEYSWfTCH This only in center position selects all four modes of operation of the control panel This key when counterclockwise the SYSTEM system goes into mode of operation When the key is returned DAY mode At this point a momentary into the DAY NIGHT armed mode of operation A subsequent action either if no disturbance

Related Files