Ademco - 4080EU Alarm Logiccenter
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-4080eu-alarm-logiccenter-8025491637.pdf |
---|---|
Type | |
Size | 2.36 MB |
Downloads |
Text Preview
No 4Q80EU LOGICENTER INFORMATION NO 4080EU Alarm LogiCenter is a microcomputer controlled control panel that provides every imp ant required for either a household fire burglary or commercial burglary alarm installation and more than any prior Ademco control panel The following listing of the LogiCenter features will assist the in becoming familiar with the panel capabilities Introduction Six burglary zones an emergency zone and a fire zone all fully supervised two wire zones with end of resistors for all intact zones Zone independence on the six burglary zones with automatic bell shut off and subsequent restoration of Alarm memory by zone Indication maintained until the system is reset Built in opening closing or armed disarmed status digital communicator output signal capability forexter control Built in siren driver Three position Arming Disarming and System Check Reset as well as built in arming capability via optional keyswitch remote stations e g No 246 or via No 216.12 Adapter 215 12 Digital Keypad Remote Station s keyswitch Power supply with 12V SAH sealed lead acid non venting rechargeable battery No 630 and wired in transformer inside the cabinet Up to 45 hours of standby time dependent upon auxiliary load drawn from continuous current auxiliary output terminals see table in General Specifications Very high regulated continuous current DC output available for powering auxiliary devices up to 500ma at Zone Inputs Main Entry Exit Delay Zone 1 a Field Selectable entry delay of 1536 or 60 seconds and exit delay of 30 or 120 seconds b Accepts open and closed circuit devices c LED annunciation of zone status and memory d Provision for remote entry delay disable switch Auxiliary Delay Zone 2 a Permits delaying the activation of space protection and or motion detection covering the area in which the control is located or the normal entry exit path to from the control If zone is violated subsequent to arming but prior to the entry zone being disturbed for instance by in who stay behind or who entervia azone other than the main entry exit zoiie the panel will alarm in b Accepts open and closed circuit devices c LED annunciation of zone status and alarm memory Night Zones 3,4 a Accepts open and closed circuit devices b LED annunciation of zone status and memory c Normal response minimizes false alarms from brief momentary disturbances Fast option permits use of vibration sensors e g No 11 Vibration Contact or No 9 Glass Sentry Day Night Zones 56 a Optional day trouble annunciation Disturbance during disarmed period sounds buzzer and optional remote sounders and lights zone status annunciator LED To silence buzzer key switch on panel momentarily to CHECK RESET Disturbance during armed period causes im alarm b Accepts open and closed circuit devices c LED annunciation of zone status and alarm d Fast slow response option Firi zone 7 a 24 hour supervised circuit b Accepts open circuit devices c Trouble in the loop during period is annunciated by rapidly flashing STATUS LED and rapidly pulsing buzzer and optional sounder d Automatic buzz back when trouble condition is cleared Silent Emergency or Audible Panic Zone 6 a 24 hour supervised latching circuit b Accepts open and circuit momentary or lock in type devices c Silent Audible option outputs circuit w smoke detectors A separate interruptible dual slow puiselrapid pulse for panic burglary fire dlstinction super loud slren driver of 20 watts output similar to No 714 into up to four 8 ohm siren speakers of the No 713 type by regulated 12 V DC from No 4080EU Alarm Relay 2 sets of dry contacts one set of which is used to power a bell if that sounding device is and or bell cutoff times are selectable as 10 or 30 minutes or continuous until panel is disarmed DC continuous current output 566 ma maximum load to power auxiliary devices such as space pro products remote arming stations DETECTOR RESET switch DC power output capable of supplying up to 250 ma from the 500 ma available current is provided for smoke detectors and Closing signal communicator output triggers as well as individual zone outputs from ail 8 and fire trouble mains supervision and shunted zone closing outputs The closing signal output is not activated until the entry exit delay door is opened and closed The opening signal output low activated when the control is disarmed A bypassed zone output signal is produced if applicable only if when a closing signal is produced pm alarm sounder as well as output for optional remote sounders such as No 70612 sounds dur the entry delay if that zone is disturbed while the panel is armed and during the exit delay if one or more the four non delay burglary zones is disturbed or bypassed will sound exit buzzer warning for Pseconds a zone s has been bypassed or longer to signal that system must be turned off immediately to avoid because a faulted zone s has not been bypassed If a non delay burglary zone s is disturbed during an immediate alarm will result mains supenrisory LED and buzzer Loss of mains will result in the buzzer sounding steadily and the being extinguished Note If desired the buzzer on loss of mains can be permanently disabled by con the wire from terminal D3 to DC the wire from Dl or terminal B17 This will also suppress the Power Loss communicator output trigger Other Features Automatic Bell Test and Subscriber Confidence Signal Selectable During arming the bell or siren will 2 seconds from the battery only and again for 112 second at the end of the exit automatically to indicate orooer armina individual bypass switches for each of the six burglary zones to provide the capability of user zone bypass Quick test feature permits installer to test delay times of entry exit bell cutoff in 1110or 1160of their normal desired intervals Zone terminal strip can be unplugged with zone wiring intact to facilitate quick and easy replacement of board should it be necessary information window in cover of cabinet which surrounds the LEDs and zone switches is protected physical attack An alarm that already has been tripped will continue if forced entry into the panel attempted at this point Automatic Low Battery Cutsff prevents deep discharge of battery by cutting off current drain from the should the voltage fall below approximately 9.8 to 10.5 volts DESCRIPTION See Diagram 1 Switches SYSTEM CHECK RESET and ARM DISARM KEYSWiTCH This three position circular keyswitch only in center position selects all four modes of operation of the control panel This key when anticlockwise the SYSTEM mode of operation When the key is returned to the center position the system goes into DAY mode At this point a momentary clockwise rotation toggling arms the system by putting it into NIGHT armed mode of operation A subsequent toggle action either returns the system to the DAY if no disturbance occurred during the night or to the NIGHT MEMORY mode if a disturbance had at night in which case the system should be RESET as explained above in order to find out if faulted zone s is still disturbed center position and left there puts the system BURGLAR ON OFF BYPASS SWITCHES Zone 1 6 Each burglary zone can be individually bypassed for reasons only when the system is in the CHECK RESET mode In any other mode these switches inoperative FIRE NORMAL TROUBLE SWITCH Zone 7 An open circuit in the supervised fire detection loop can be ignored by placing this switch in the TROUBLE position and turning the function keyswitch to CHECK RESET mode This will silence the rapidly pulsating fire trouble buzzer The will buzz back if this switch is still in the TROUBLE position when the loop is repaired Switch