Ademco - 4204 Relay Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-4204-relay-module-2174608593.pdf |
---|---|
Type | |
Size | 883.55 KB |
Downloads |
Text Preview
Several of you have written us to ask that we reconsider this decision We have Tech Man Subscriber apologizes for any misunderstanding that has arisen due to our recent to have our technical information removed from the Tech Man web site You appreciate that one of our key concerns is to provide installing security dealers with and accurate information on our products and we were concerned about the data to the Tech Man web site For obvious reasons we also do not wish unauthorized to have access to information on installing and configuring ADEMCO These concerns were what prompted us to ask Tech Man to stop posting installation instructions and user manuals will not require Tech Man to remove the ADEMCO data ADEMCO however is responsible for the operation and maintenance of this site thus we cannot guarantee timeliness or accuracy of the information posted on the Tech Man web site data about our products You may request a PIN number for access to the Technical Support web site and FAXBACK system you need assistance on troubleshooting or if you have other technical questions our products not addressed in the information posted at our web site please contact Technical Support at 800 645 7492 ADEMCO web site is located at www ademco com and contains accurate you for understanding Lustig 4204 RELAY MODULE Use With Control Communicators Supporting Module Connection Via Keypad Lines INSTRUCTIONS INFORMATION 4204 Relay Module adds from one to four dry form C relay outputs to compatible control communicators It to the control cid 213 s keypad wiring 4204 can be mounted inside the control cid 213 s cabinet or remotely mounted remotely the 4204 has two forms of protection the 4204 has a built in tamper switch which allows it to and report the removal of its cover to the control communication to the 4204 is supervised so that it be disconnected from the keypad wiring without by the control If the wiring is cut a tamper or alarm will result to indicate that this device and possibly devices connected to the keypad wiring has become UL Installations used with controls which do not support cover or supervise communications wiring to the 4204 the 4204 inside the control cid 213 s cabinet used with controls which support cover tamper supervise communications wiring to the 4204 the may either be mounted inside the control cid 213 s cabinet mounted remotely mounted inside the control cabinet some controls the 4204 to be mounted horizontally as follows insert self tapping screws provided in two adjacent raised on the back of the cabinet Leave the heads projecting Hang the 4204 on the screw heads via two of the slot holes on the back of its housing The 4204 cid 213 s cover need in this case be tamper protected If the DIP switch is set its position 1 cid 210 ON cid 211 see the table below the cover can left off See the control instructions for additional infor the 4204 is mounted remotely holes on its back it to be mounted horizontally or vertically Wires can exit the side or via the breakout on the back of its housing DIP switch must be set with its position 1 cid 210 OFF cid 211 and when installation is completed the unit cid 213 s tamper protected cover be replaced the connections label that accompanies the 4204 to the of the 4204 if the cover is used or to the inside the control cover AND SETTINGS and set an address for the 4204 using its DIP switch shown in the table below Each 4204 used with the control be assigned a unique address so the control can identi the 4204 and communicate with it properly The address to set is determined by the particular control to be used and control installation instructions must be consulted As the DIP switch is set for an address of cid 210 0 cid 211 to the 4204 four relays are made via 12 posi terminal block TB2 Refer to the control cid 213 s installation for specific information on how to program the various activation options for the relays to the control keypad wiring points can be via 4 position terminal block TB1 the 4 pin plug or both color connections are the same See the diagram on the side of this page W x 4 1 4 cid 211 H x 1 1 4 cid 211 D x 108mm x 32mm Voltage 12VDC nominal 10 from control cid 213 s keypad connection points Current 15mA standby 40mA per active relay Rating 2A max at 28VDC AC resistive loads SWITCH SETTINGS 2 0 4 A D D R E S S S E T T I N G S means OFF cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON cid 209 ON ON cid 209 cid 209 ON ON cid 209 cid 209 ON ON cid 209 cid 209 ON ON ON ON cid 209 cid 209 cid 209 ON ON ON ON ON cid 209 cid 209 cid 209 cid 209 cid 209 SWITCH AREAS DENOTE SWITCH HANDLES 2 DETERMINE 4204 ADDRESS CONTROL cid 213 S INSTRUCTIONS FOR ADDRESS TO USE SET AS SHIPPED FOR ADDRESS 0 1 DETERMINES COVER TAMPER RESPONSE DISABLED SHOWN AS SHIPPED ENABLED COVER IS TAMPER PROTECTED SWITCH SETTING DEVICE ADDRESS ENABLING DISABLING TAMPER TAMPER REED SWITCH OFF KEYPAD PLUG CONSOLE PLUG CONTACTS ARE SUPERVISED OR BOTH BE USED 14 15 16 IN CONTROL GROUND OUT CONTROL 12V CONNECTIONS TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE USED FOR DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM LIMITED WARRANTY Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates 165 Eileen Way Syosset New York 11791 warrants its products to be in conformance with its own plans specifications and to be free from defects in materials and workmanship under normal use and service for 24 from the date stamp control on the product or for products not having an Ademco date stamp for 12 months date of original purchase unless the installation instructions or catalog sets forth a shorter period in which case shorter period shall apply Seller obligation shall be limited to repairing or replacing at its option free of charge materials or labor any product which is proved not in compliance with Seller specifications or proves defective in or workmanship under normal use and service Seller shall have no obligation under this Limited Warranty otherwise if the product is altered or improperly repaired or serviced by anyone other than Ademco service For warranty service return product transportation prepaid to Factory Service 165 Eileen Way Syosset New York 11791 ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICU PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF IN NO SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER OWN NEGLIGENCE FAULT does not represent that the products it sells may not be compromised or circumvented that the products will any personal injury or property loss by burglary robbery fire or otherwise or that the products will in all cases adequate warning or protection Customer understands that a properly installed and maintained alarm may reduce the risk of a burglary robbery fire or other events occurring without providing an alarm but it is not or a guarantee that such will not occur or that there will be no personal injury or property loss as a result SELL