Ademco - 4204CF Appliance Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-4204cf-appliance-module-1970852463.pdf |
---|---|
Type | |
Size | 889.43 KB |
Downloads |
Text Preview
Several of you have written us to ask that we reconsider this decision We have Tech Man Subscriber apologizes for any misunderstanding that has arisen due to our recent to have our technical information removed from the Tech Man web site You appreciate that one of our key concerns is to provide installing security dealers with and accurate information on our products and we were concerned about the data to the Tech Man web site For obvious reasons we also do not wish unauthorized to have access to information on installing and configuring ADEMCO These concerns were what prompted us to ask Tech Man to stop posting installation instructions and user manuals will not require Tech Man to remove the ADEMCO data ADEMCO however is responsible for the operation and maintenance of this site thus we cannot guarantee timeliness or accuracy of the information posted on the Tech Man web site data about our products You may request a PIN number for access to the Technical Support web site and FAXBACK system you need assistance on troubleshooting or if you have other technical questions our products not addressed in the information posted at our web site please contact Technical Support at 800 645 7492 ADEMCO web site is located at www ademco com and contains accurate you for understanding Lustig 6 96 4204CF U P E R V I S E D N O T I F I C AT I O N A P P L I A N C E M O D U L E INSTRUCTIONS INFORMATION and Settings 4204CF Supervised Notification Appliance Module adds up to 2 B Style Y Supervised Notification Appliance Outputs to compati ADEMCO Control Panels for more information on Style Y see NFPA National Fire Alarm Code Chapter 3 Protected Premises Fire Alarm Refer to your control panel cid 213 s installation instructions to deter if it supports this module Each output is supervised using a model 2K EOL resistor 2 resistors supplied and set an address for the 4204CF using its DIP switch settings as in Diagram 1 Assign a unique address to the 4204CF so that the can communicate with it Refer to the control cid 213 s Installation to determine which address or range of addresses to use connections to the control keypad wiring by using the 4 position block TB1 or the 4 pin plug plug cable provided Make con to the Notification Appliance Power input and outputs via the 12 position terminal block TB2 refer to Diagrams 2 3 4 appliance output is rated at 1.2A max You can power these out from the Control Panel or from a supplementary UL864 commercial listed power limited power supply rated at 8 30 VDC full wave rectified unfiltered 4204CF connects to the control via the control keypad wiring the Control Panel keypad wiring the 4204CF receives output acti commands and sends output supervision status back to the Panel Only relay 1 Output A and relay 3 Output B may be pro for activation Refer to the control cid 213 s Installation for programming output activation and supervi options When programming 4204CF output activation options in the panel outputs must not be programmed to cid 210 Close 2 Seconds cid 211 Any other option may be used but do not the relay to cid 211 Stop cid 211 in less than 10 seconds 4204CF has a built in cover tamper switch which allows it to detect report the removal of its cover to the Control Panel fire alarm installations mount the 4204CF inside a U L 864 listed such as the control cid 213 s cabinet or the supplementary power supply if used Cover tamper supervision is not required to disable supervision set DIP switch Position 1 to the ON position Input W x 4 1 4 cid 211 H x 1 1 4 cid 211 D x 108mm x 32mm Cover tamper supervision is not supported by all control For other i e non fire alarm installations a sep enclosure is not required Mount the 4204CF direct on a surface using the slotted holes located on the back its housing mounting screws provided Feed the wires the slot on the side or through the breakout locat on the back of the housing Cover tamper supervision be used if supported by the control panel Affix the connections label provided to the inside of the cover Voltage 12VDC 10 14VDC Current 80mA per active output Appliance Power Input Voltage Current VDC or VFW mA when both outputs inactive Up to 2.4A when outputs are active Appliance Outputs Voltage Supplied by notification appliance power input Current Each output must be limited to 1.2A max Outputs are supervised Style Y using 610 7 2K EOL and are power limited Refer to the instruc for the notification power supply used for a list of indicating devices 1 ENABLES DISABLES TAMPER TAMPER DISABLED SHOWN AS SHIPPED TAMPER ENABLED 2 5 DETERMINE 4204CF INSTRUCTIONS SPECIFY TO USE ADDRESS SETTING SHOWN AS 2 0 4 C F A D D R E S S S E T T I N G S means OFF 15 ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON SWITCH WHITE AREAS DENOTE SWITCH HANDLES SWITCH SETTING DEVICE AND ENABLING TAMPER TAMPER REED SWITCH CONSOLE PLUG OR BOTH BE USED 14 15 16 B EOLR A EOLR FOR NOTIFICATION OUTPUTS A B VDC OR VFW UP TO 2.4A ON NOTIFICATION CURRENT ALARM POLARITY EACH OUTPUT STYLE Y EACH OUTPUT RATED MAX USE NOTIFICATION WITH POWER VOLTAGE APPLIANCE CONSOLE DATA ARE POWER IN CONTROL GROUND OUT CONTROL 12VDC SUPPLIES POWER TO CIRCUITRY INCLUDING OUTPUT RELAY COILS DRAIN AT 12V IS mA 80mA PER ACTIVE OUTPUT 1 SETTINGS AND CONNECTIONS FOR NOTIFICATION APPLIANCES NOT EXCEED CONTROL AUX POWER CURRENT RATING POWER DATA DATA TO CONTROL FROM CONTROL APPLIANCE OUTPUT A APPLIANCE OUTPUT B WIRE MAY BE USED THE 4204CF WITHIN 3 FEET OF THE CONTROL WIRES IN CONDUIT SUPERVISION OF WIRING NOT REQUIRED 2 MODULE AND NOTIFICATION APPLIANCES POWERED FROM CONTROL AC BATTERY TO EOLR SUPERVISED ON CONTROL SUPPLY WHEN NOTIFICATION APPLIANCE POWER IS THE EOL RELAY WILL DISRUPT MODULE CAUSING THE CONTROL TO DETECT A 4204CF FAULT POWER DATA DATA TO CONTROL FROM CONTROL UL COMMERCIAL LISTED SUPPLY VDC OR VFW FOR NOTIFICATION APPLIANCES NOT EXCEED SUPPLY CURRENT RATING RELAY BE USED WHEN 4204CF MORE THAN 3 FEET FROM POWER FOR FIRE ALARM INSTALLATION RELAY NEAR 4204CF SENSOR MODEL A77 716B MAY BE WITH 12V SUPPLY APPLIANCE OUTPUT A APPLIANCE OUTPUT B TO CONTROL INSTRUCTIONS FOR MAX COMBINED LENGTH OF WIRE RUNS THAT CAN