Ademco - 4208U 8-Point Zone Expander

File Preview
File Preview
Click below to download for free

File Data

Name ademco-4208u-8-point-zone-expander-4026759183.pdf
Type PDF
Size 915.10 KB
Downloads

Text Preview

Several of you have written us to ask that we reconsider this decision We have Tech Man Subscriber apologizes for any misunderstanding that has arisen due to our recent to have our technical information removed from the Tech Man web site You appreciate that one of our key concerns is to provide installing security dealers with and accurate information on our products and we were concerned about the data to the Tech Man web site For obvious reasons we also do not wish unauthorized to have access to information on installing and configuring ADEMCO These concerns were what prompted us to ask Tech Man to stop posting installation instructions and user manuals will not require Tech Man to remove the ADEMCO data ADEMCO however is responsible for the operation and maintenance of this site thus we cannot guarantee timeliness or accuracy of the information posted on the Tech Man web site data about our products You may request a PIN number for access to the Technical Support web site and FAXBACK system you need assistance on troubleshooting or if you have other technical questions our products not addressed in the information posted at our web site please contact Technical Support at 800 645 7492 ADEMCO web site is located at www ademco com and contains accurate you for understanding Lustig Universal Eight Zone Remote Point Module Instructions 11 96 ADEMCO 4208U Remote Point Module RPM is an expander which allows use of the available zones provided by ADEMCO controls that polling loop devices Characteristics of this include Can be optionally powered from an external DC supply to reduce current draw from the loop Uniquely identifies 8 EOLR supervised zones zones use 10k resistors supplied DIP Switches can be used to set zone numbers serial numbers When used in the serial number mode each number in the selected group can be to any zone number A B can be programmed for fast 10 response protected Power should be disconnected before proceeding Be sure to mount the 4208U before any wiring connections mounted inside the cabinet with the control the should be mounted horizontally and does not to be tamper protected Insert two screws into the metal tabs leaving the heads app 1 8 exposed hang the 4208U using the two slots on the back mounted in the cabinet the 4208U does not need be tamper protected or have the cover on except in installations mounted remotely the 4208U can be mounted or vertically Tamper protection should be via the DIP switches and the cover put on If protection is required be sure to enable the zone tamper option at the control program 24 0 Tamper protection is provided by a magnet the cover and a reed switch mounted on the device If cover is opened a trouble will be sent to the control every active zone on the 4208U module For UL Listed Commercial Burglary 4208U must be tamper protected or in a tamper protected cabinet For all UL installations the cover must on the unit even if the unit is in the control cabinet loop and protection loop wires can be brought in through the back or front of the unit by removing knockouts Use 22 gauge twisted pair wire for polling connections All protection loops use 10k EOL included A maximum resistance of 300 ohms allowed on protection loops excluding EOLR See 2 for all connections Keep in mind that connec to the polling loop are always required while power connections are optional SWITCH SETTINGS Assignment Mode the zone assignment mode the DIP Switches on the are used to assign the unit to a group of 8 zones These zone numbers once for the 4208U cannot be used for anything even if you don use all 8 Follow the steps below Table 1 for DIP Switch settings Number Mode the serial number mode the DIP Switches on the are used to assign the unit to a group of 8 serial You can assign any serial number to any number except hardwire zone numbers on the and you do not lose zone numbers if you don all eight loops on the 4208U Follow the steps below Table 2 for DIP Switch settings the DIP Switches on the 4208U as instructed below Figure 1 Select fast slow response for loops A and using DIP Switch 1 Fast OFF Slow ON 400msec Select mode of operation serial number or assignment mode using DIP Switch Serial Number mode ON Zone mode OFF 1 DIP Switch Settings See Table 1 Select the group setting using Dip switches 5 zone or Table 2 for serial number If using more than one be sure to set each one to a group setting DIP Switch 7 Not Used set to OFF Select 4208U Tamper Protection using DIP Switch 8 Tamper ON Tamper Enabled OFF will report for every active zone on 4208U module OPTIONAL 2 Summary of Connections 1 4208U Zone Assignments 2 4208U Serial Number Assignments setting the 4208U to a group of zone numbers zone must be programmed as follows 4140XMP and earlier controls these zones must programmed as Left Loop Polling Loop zones Vista 40 and later controls these zones must be Zone as INPUT TYPE Switch type loop device DP 93 Menu Mode setting the 4208U to a group of serial numbers zone must be programmed as INPUT TYPE Serial Number Polling Loop Device Loops can be in any order and assigned to any legitimate zone prompted to Learn the serial number for a zone you may either enter it manually through keypad or through V Link or it in by faulting shorting the terminals of that zone required by the control If entering a serial number through the keypad enter it and press to to the next prompt which will ask you for the number Enter a for each serial number entered learning or entering a serial number and the message of Zone XX is displayed another device with same serial number is aready in the system In that use a different serial number group setting on the learning a serial number by faulting associated loop be sure that other loop devices are not activated they may interfere with the device learned OF PROGRAMMING verify proper programming the following test should performed Be sure to enable expansion zone tamper protection the control program field 24 0 Set DIP Switch 8 to OFF tamper enabled Replace the 4208U cover and clear the keypad of faulted zones Remove the 4208U cover and verify on the that only the zones you designated for this are indicating a check or trouble condition Input Source Voltage 11 14VDC Draw zones shorted Polling Loop External Power Loop Only Loop and External Input mA mA mA 3 Current Draw Calculations 6 7 6 163mm 4 1 4 108mm 1 1 4 32mm loop input 7.3 14VDC draw 28.6mA max external power and polling see Table 3 Power Input optional 28mA from control panel auxiliary power Loop Response 400msec all loops 10msec option for loops A and B Loop Current polling loop input 11VDC no external power input normal shorted Loop Max Resistance to 300 ohms of wire resistance 10k EOLR UL Listed Commercial Fire Usage N O contacts Style B supervise these loops using EOL100 fire listed 10k EOLRs purchased separately UL Listed Commercial Burglary Usage N O or N C contacts Supervise using EOLRs supplied Limited Warranty Device Manufacturing Company a Division of Pittway Corporation and its divisions subsidiaries and affiliates Seller

Related Files