Ademco - 5808 Commercial Smoke Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-5808-commercial-smoke-detector-7064195382.pdf |
---|---|
Type | |
Size | 912.20 KB |
Downloads |
Text Preview
Several of you have written us to ask that we reconsider this decision We have Tech Man Subscriber apologizes for any misunderstanding that has arisen due to our recent to have our technical information removed from the Tech Man web site You appreciate that one of our key concerns is to provide installing security dealers with and accurate information on our products and we were concerned about the data to the Tech Man web site For obvious reasons we also do not wish unauthorized to have access to information on installing and configuring ADEMCO These concerns were what prompted us to ask Tech Man to stop posting installation instructions and user manuals will not require Tech Man to remove the ADEMCO data ADEMCO however is responsible for the operation and maintenance of this site thus we cannot guarantee timeliness or accuracy of the information posted on the Tech Man web site data about our products You may request a PIN number for access to the Technical Support web site and FAXBACK system you need assistance on troubleshooting or if you have other technical questions our products not addressed in the information posted at our web site please contact Technical Support at 800 645 7492 ADEMCO web site is located at www ademco com and contains accurate you for understanding Lustig use with QED control panel ONLY Photoelectronic Smoke Heat Detector with Photoelectronic Smoke Heat Detector with Photoelectronic Smoke Heat Detector with Photoelectronic Smoke Heat Detector with Photoelectronic Smoke Heat Detector with TTTTTransmitter Installation Instructions Installation Instructions Installation Instructions Wireless Installation Instructions Installation Instructions 3 volt CR123A Lithium Batteries included Replace with Duracell DL123A Sanyo Panasonic CR123A ADEMCO 466 or Varta CR123A Source Limits Maintenance signal activated at either smoke level Ambient Temperature Range Humidity Range Sensor Listings Sensitivity 0.65 0.15 per foot Sensitivity less than 6 per foot inches 14 cm inches 64 mm lb 310 g to 37.8 C 40 to 100 F to 95 Relative Humidity F Fixed Temperature Electronic Thermistors 217 UL 268 Residential Commercial Installations installing detectors please thoroughly read these installation instruc and Manual I56 407 Guide for Proper Use of System Smoke Detectors provides detailed information on detector spacing placement zoning and special applications Copies of this manual are available from This manual should be left with the owner user of this equipment This detector must be tested and maintained regularly following 72 requirements The detector should be cleaned at least once a year Do not use the maintenance signal as an indication that the has reached the limits of its nominal sensitivity range Maintenance indicates that the detector may need cleaning or can no longer respond smoke and shall not be used as a sensitivity indicating means DESCRIPTION 5808 photoelectronic smoke heat detector with built in wireless transmit is intended for use with wireless alarm systems that support QED 5800 devices Refer to QED control communicator installation instructions compatibility The 5808 smoke heat detector can be used with 5881 series M H and 5881EH receivers for residential installations The 5808 smoke detector can be used with the 5881EH receiver for commercial installa The transmitter can send alarm tamper maintenance when QED panels are equipped to process maintenance signals and battery messages to the QED system receiver The maintenance signal either indicate that the photo chamber requires cleaning or that the detector no longer respond to smoke and may need replacement Refer to the system instructions for the maximum number of transmitters that can supported 5808 sounds its built in horn when smoke reaches the detector the also flashes rapidly or when the air temperature reaches 135 F the flashes normally about once every 40 seconds A message is also to the wireless QED control panel and the smoke detector ID number displayed at the console The alarm message is transmitted every 4 until the smoke condition has cleared and the detector has reset 1 second after the horn stops a RESTORE message is transmitted the QED control panel and the ID number can be cleared from the panel normal maintenance and low battery conditions the LED flashes once every 40 seconds INSTALLATION AND REPLACEMENT 5808 is powered by two 3 volt CR123A or DL123A Lithium batteries The detector checks for low batteries at every normal LED flash a low battery is detected the transmitter sends a low battery message to QED control panel which beeps and displays the detector ID This will exist for a minimum of seven days and then the detector will chirp about every 40 seconds The batteries should be replaced the chirps begin BE SURE TO REPLACE BOTH BATTERIES FRESH ONES replace batteries Remove the detector from its mounting plate by twisting the detector counter Remove batteries if replacing and dispose properly two new 3 volt CR123A Lithium batteries in the battery compart Follow the polarity diagram inside the compartment Reinstall the smoke detector onto the mounting plate by turning the clockwise Test the detector as described in the TESTING TRANSMITTER SIG section of this manual The LED should flash about once every 40 to indicate normal operation If the batteries are not installed the smoke detector will not operate and the batteries may be If the detector does not appear to be sending a signal during of the tests check for correct battery installation Light Normal Thermal Alarm Blink Smoke Alarm Call for Service Switch Module Port 1 5808 Wireless Smoke Heat Detector smoke detector ID must be enrolled in the QED control panel during of the system The QED control panel should be programmed enroll the 5808 as an unit must be programmed as RF UL installations Put the QED control panel in the program mode and perform the following the QED control panel program the detector as loop 1 and either enter the serial number that is on the label of the 5808 or press test switch to cause a transmission Additional transmissions will cause display to appear on the keypad display the QED control unit installation instructions for further details 165 Eileen Way Syosset New York 11791 DETECTOR LIMITATIONS Smoke detectors will not sense a fire if the smoke does not reach the or if the air temperature does not reach 135 F In order for a detector to sense smoke it must be installed in the immediate of the fire In addition smoke from fires in chimneys in walls on in remote parts of the building or on another level from where the detector is located may not reach the smoke detector quickly for occupants to escape unharmed For this reason installer install smoke detectors on every level in every sleeping area in every bedroom of the household Smoke detectors may not be heard The alarm horn in this smoke meets or exceeds current Underwriter Laboratories standards if the smoke detector is not located in the same room as the or if it is blocked by a closed door or normal noise the alarm horn not be heard In addition sound sleepers or persons who are under influence of drugs or alcohol may not hear the alarm or be able to react it Therefore locate this smoke detector which has a sounder rated 85 dB at 10 feet on every level in every sleeping area and in every of the household In general detectors may not always warn you about fires caused by and safety hazards like smoking in bed violent explosions gas improper storage of flammable materials overloaded elec circuits children playing with matches or arson Smoke detectors are not fool proof Like all electronic devices smoke have limitations No type of smoke detector can sense every of fire every time In addition smoke from slow smoldering fires slowly and may not reach the s