Ademco - 5816 Door-Window Transmitter

File Preview
File Preview
Click below to download for free

File Data

Name ademco-5816-door-window-transmitter-2548976103.pdf
Type PDF
Size 892.99 KB
Downloads

Text Preview

CHANGES IN THIS ISSUE ARE INDICATED BY MARGIN LINES TALLATION UCTIONS Rev B 5816 ALIGNMENT STRIP A SEE PRY OFF POINT MAGNET WITH ON CASE AND ON MTG PLATE 2 2 MAX 1 2 2 2 Diagram 1 Mounting Plate Diagram 2 Transmitter Cover Removed TAB WINDOW FOR CONCEALED ACCESS FOR SURFACE WIRING ACCESS INFORMATION No 5816 Door Window Transmitter has its own serial numbers permanently assigned during The control unit is required to learn transmitter serial Nos at point prior to its usage in the alarm system to the control unit installation instructions for details Note During programming of the unit 5816 transmitters should be treated as i e supervised RF Type mandatory for UL 5816 has two unique zones the first is for a circuit contact loop and the second for its reed switch used in conjunction with a mag as described below Either or both zones may used For UL installations a contact may not be than 3 feet from the transmitter built in cover tamper switch is activated when the is removed proper orientation of the unit in relation to the plate loop wiring and or magnet read all this section before installing the unit description that follows assumes that the unit be mounted as shown in the diagrams with the if used located to the unit right The unit however be installed in any direction as long the relationship of the unit to its mounting plate if used magnet is maintained two holes are provided in the unit that permit mounting directly to a surface holes Diagram 2 it is recommended that the mounting be used for ease in removing the unit for should it become necessary mounting the transmitter permanently Go No Go tests see control instructions verify adequate signal strength and reorient or the transmitter if necessary Remove the transmitter cover by inserting the blade of a small screwdriver into the pry off at the end of the unit farthest from the decorative ribs and twisting the blade Disengage the supplied mounting plate from the by inserting the blade of a small screwdriver the locking tab release window see Di 2 and pressing it against the locking tab Diagram 1 while sliding the plate downward the case back a wired contact loop is to be used with con wiring feed the wires through the con wiring entry hole at one corner of the plate surface wiring entry a thin breakout area is in the case wall Wiring can be run this cid 210 breakout cid 211 in the case when the case in step 5 the mounting plate with its case holding pointing up in this example in the selected as described in the control installation instructions Use the flat head supplied Attach the case back to the mounting plate by the keyhole slots in the case back down the mounting plate case holding posts locking tab will click as the case back in place the unit reed switch is to be used a Magnet obtain separately should be adjacent to the alignment marks on the and the mounting plate alignment strip Diagram 2 Connections the battery still not inserted connect the loop if used to the unit loop terminals see The contact loop must use closed circuit The loop response time is a nominal the contact loop is not to be used no con is needed across its terminals INSTALLATION REPLACEMENT Remove the transmitter cover if it is not al off as described in Mounting Step 1 Observe correct polarity and insert the battery into the battery holder see Diagram care not to bend the antenna Replace battery only with CR123A Duracell DL123A CR123A or Ademco 466 To replace the cover engage the hooks along edge and snap shut x 3 1 16 H x 1 3 16 D x 78mm x 30mm Lithium see Note in step 2 of INSTALLATION REPLACEMENT CAUTION Risk of fire explosion burns Do not recharge disassemble heat 212 cid 176 F 100 cid 176 C or incinerate Dispose of batteries promptly Keep away from THE INSTALLER maintenance and inspection at least annually by the installer and frequent testing by the user are to continuous satisfactory operation of any alarm system installer should assume the responsibility of developing and offering a regular maintenance program to user as well as acquainting the user with the proper operation and limitations of the alarm system and component parts Recommendations must be included for a specific program of frequent testing at least to insure the system operation at all times TO THE FOR THE WITH WHICH THIS DEVICE IS USED FOR REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM LIMITED WARRANTY Device Manufacturing Company a Division of Pittway Corporation and its divisions sub and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to in conformance with its own plans and specifications and to be free from defects in materials and under normal use and service for 18 months from the date stamp control on the product for products not having an Ademco date stamp for 12 months from date of original purchase unless installation instructions or catalog sets forth a shorter period in which case the shorter period shall Seller obligation shall be limited to repairing or replacing at its option free of charge for or labor any product which is proved not in compliance with Seller specifications or defective in materials or workmanship under normal use and service Seller shall have no under this Limited Warranty or otherwise if the product is altered or improperly repaired or by anyone other than Ademco factory service For warranty service return product prepaid to Ademco Factory Service 165 Eileen Way Syosset New York 11791 ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER OWN OR FAULT does not represent that the products it sells may not be compromised or circumvented that the will prevent any personal injury or property loss by burglary robbery fire or otherwise or the products will in all cases provide adequate warning or protection Customer understands that a installed and maintained alarm may only reduce the risk of a burglary robbery fire or other occurring without providing an alarm but it is not insurance or a guarantee that such will not or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF OR ORIGIN SELLER MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PRICE OF THE PRODUCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE AGAINST SELLER This warranty replaces any previous warranties and is the only made by Seller on this product No increase or alteration written or verbal of the obligations this Limited Warranty is authorized DEVICE MANUFACTURING COMPANY DIVISION OF PITTWAY CORPORATION Eileen Way Syosset New York 11791 Rev B 1992 PITTWAY CORPORATION

Related Files