Ademco - 5816MN Door-Window Transmitter

File Preview
File Preview
Click below to download for free

File Data

Name ademco-5816mn-door-window-transmitter-9173254086.pdf
Type PDF
Size 938.59 KB
Downloads

Text Preview

2 2 4 98 TRANSMITTER use with QED control panels ONLY SWITCH LOOP 2 EXIT IN HERE USING DIA MAX 1 Mounting Plate INFORMATION 5816MN Door Window Transmitter has its own serial number permanently assigned during The QED control unit is required to the transmitter ID at some point prior to its in the alarm system Refer to the QED control installation instruc tions for further details Note programming of the QED control unit 5816MN should be treated as RF i e supervised Type mandatory for UL installations 5816MN can send two unique codes the first for a closed circuit contact loop and the second for its reed switch used in conjunction with a magnet described below A wired loop and or reed switch be used For UL installations a contact may not more than 3 feet from the transmitter 5816MN includes a built in cover tamper which is when the cover is removed proper orientation of the unit in relation to the plate loop wiring and or magnet read all of section before installing the unit description that follows assumes that the unit will mounted as shown in the diagrams with the magnet used located in one of the positions shown in Figure The unit may however be installed in any direction long as the relationship of the unit to its mounting and if used magnet is maintained the unit can be mounted directly to a surface is recommended that the mounting plate be used for in removing the unit for servicing should it necessary mounting the transmitter permanently conduct Go tests see QED control instructions to adequate signal strength and reorient or relocate transmitter if necessary Remove the transmitter cover by inserting the blade of a small screwdriver into the pry off slot the end of the unit farthest from the cover ribs see Fig 2 for location and twist the blade Disengage the supplied mounting plate from unit by inserting the blade of a small screw TAB PRY OFF MAGNET MARKS CASE MAX TERMINALS 1 ENTRY HOLE BACK OF CASE FOR WIRING POSITION FOR Figure 2 5816MN shown without cover into the locking tab release window see Fig and pressing it against the locking tab shown in 1 while sliding the plate downward along the back the mounting plate with its case holding pointing up in this example in the location as described in the QED control unit instruc tions Use the flat head screws If a wired contact loop is to be used with wiring the wire exit hole in the should be in the location shown in 1 and no more than 1 4 in a wired contact loop is to be used feed wiring through the slot in the case back do not connect to the ter minal block yet For wiring entry a thin breakout area is in the case wall see Fig 2 for location Attach the case back to the mounting plate by the key hole slots in the case back down the mounting plate case holding posts The tab will click as the case back locks in one of the reed switches in the unit is to be a No 5899 Magnet obtain separately be mounted adjacent to the alignment on the right side of the case or adjacent to bottom of the case see Fig 2 WIRING CONNECTIONS If used the battery still not inserted connect the contact wires to the unit loop terminals see Fig 2 Make sure that the bared sections of the wires do not short to the reed switch contact loop must use closed circuit devices The response time is a nominal 100mSec If the contact loop is not to be used no is needed across the loop terminals INSTALLATION REPLACEMENT Remove the transmitter cover if it is not al off as de scribed in MOUNTING Step 1 Observe correct polarity and insert the battery into the battery holder see Fig 2 Take not to bend the antenna Replace battery only with CR123A Duracell DL123A CR123A Varta CR123A or 466 To replace the cover engage the hooks along edge and snap shut 1 1 2 W x 3 1 16 H x 15 16 D x 78mm x 24mm 3V Lithium see Note in step 2 of BATTERY CAUTION Risk of fire explosion burns Do not recharge disassemble above 212 cid 176 F 100 cid 176 C or incinerate of used batteries promptly Keep from children THE INSTALLER maintenance and inspection at least annually by the installer and frequent testing by the user are vital to satisfactory operation of any alarm system installer should assume the responsibility of developing and offering a regular maintenance program to the user well as acquaint ing the user with the proper operation and limitations of the alarm system and its component Recommendations must be included for a specific program of frequent testing at least weekly to insure the operation at all times TO THE INSTALLATION INSTRUCTIONS FOR THE QED RECEIVER CONTROL WITH THIS DEVICE IS USED FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE SYSTEM LIMITED WARRANTY Device Manufacturing Company a Division of Pittway Corporation and its divisions sub and affiliates Seller 165 Eileen Way Syosset New York 11791 warrants its products to in conformance with its own plans and specifications and to be free from defects in materials and under normal use and service for 18 months from the date stamp control on the product for products not having an ADEMCO date stamp for 12 months from date of original purchase un the installation instructions or catalog sets forth a shorter period in which case the shorter pe riod apply Seller obligation shall be limited to repairing or replacing at its option free of charge for or labor any product which is proved not in compliance with Seller specifications or defective in materials or workmanship under normal use and service Seller shall have no un der this Limited Warranty or otherwise if the product is altered or improperly repaired or by anyone other than ADEMCO factory service For warranty service return product prepaid to ADEMCO Factory Service 165 Eileen Way Syosset New York 11791 ARE NO WARRANTIES EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE ON THE FACE HEREOF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY WARRANTY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER OWN OR FAULT does not represent that the products it sells may not be compromised or circumvented that the will prevent any personal injury or property loss by burglary robbery fire or otherwise or the products will in all cases provide adequate warning or protection Customer understands that properly installed and maintained alarm may only reduce the risk of a bur glary robbery fire or other occurring without providing an alarm but it is not insurance or a guarantee that such will not or that there will be no personal injury or property loss as a result CONSEQUENTLY SELLER HAVE NO LIABILITY FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR OTHER BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING HOWEVER IF SELLER HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE UN DER THIS LIMITED WARRANTY OR OTHERWISE REGARDLESS OF CAUSE OR SELLER MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE OF THE PROD UCT WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY SELLER This war ranty replaces any previous warranties and is the only warranty made by on this product No increase or alteration written or verbal of the obliga tions of this Limited is authorized Eileen Way Syosset New York 11791 1998 Pittway Corporation

Related Files