Ademco - 5881ENL Wireless RF Receiver

File Preview
File Preview
Click below to download for free

File Data

Name ademco-5881enl-wireless-rf-receiver-4102356978.pdf
Type PDF
Size 685.55 KB
Downloads

Text Preview

INSTALLATION AND SETUP GUIDE 8 00 Series Receiver programmed ENTRY EXIT PERIMETER etc and the procedure for programming the receivers should not be installed in an area subject to extremes of below freezing such as an warehouse or extremely high temperatures such an attic some controls a receiver may be mounted directly the control cabinet receiver circuit board only its plastic housing instead of remotely in its own In both cases avoid mounting the receiver against a metal surface Remove the receiver cover by inserting and twisting screwdriver blade in the slot at the center of the cover edge If the receiver is to be mounted within the cabinet refer to Figure 1 Remove the receiver circuit board from its base by back the two flexible plastic tabs that hold board lower edge In the control cabinet unfasten and move the circuit board downward if already installed Hang two short black mounting clips provided with receiver on the raised cabinet tabs in the cabinet shown in Detail B of Figure 1 Insert the top of the receiver board the slots provided at the top of the cabinet as in Detail A Swing the bottom of the receiver into the two short black mounting clips in step c and secure it to the cabinet with accompanying screws See Detail B Insert the top of the control board into the slot in the clips holding the lower edge of the receiver see Detail B and position two long red clips the lower edge of the board see Detail C Swing the lower edge of the control board into place secure with two additional screws Insert one of the two grounding lugs provided with receiver through the top of the cabinet and into left hand terminal of one of the antenna blocks at upper edge of the receiver circuit board Secure to the cabinet with one of the two screws provided Detail D Do the same with the other ground lug and antenna the receiver two antennas through the two in the top of the cabinet one into each right hand terminal and tighten the screws to them Affix the receiver Summary of Connections label to inside of the control cabinet door 5881EN series of RF receivers is designed for use with panels that support an RF receiver connection via keypad terminals The receiver recognizes alarm status keypad control messages from wireless transmitters at 345MHz or two receivers can be depending on the control used Connection of receivers to a control can provide redundant or extend coverage in large areas receivers feature a Spatial Diversity System that eliminates the possibility of nulls and dead within the coverage area The 5881EN series of use ADEMCO new Signal Sentry technology can be used the 5881ENHC receiver contains front and tamper that permits its use in commercial burglary commercial In commercial fire applications the receiver can be used with control panels that are approved use in Commercial Fire Installations When the is used in commercial fire applications switch 5 must be in the ON position In can only be used with control panels are approved for use in Commercial Burglary In commercial fire applications a keypad must be to Keypad Port 2 in the control The must be mounted on the control or within 3 of the control with the wiring encased in receiver supports the number of zones shown below to 8 zones to 16 zones below below The number of zones that the 5881ENH can support depends on the with which it is used See the panel instructions for specific a receiver is connected to a system in which more than permitted number of wireless zones have been a SET UP ERROR message on alpha or an E4 or message on fixed word will be displayed on the system keypad and none the zones will be protected instruction manual that accompanies the control locations the types of wireless zones that can Discard the receiver unused plastic cover and base If the receiver is to be located remotely from the in its own plastic enclosure not in a cabinet will not need the circuit board mounting clips lugs and screws included with the receiver If concealed wiring is to be used route it through the opening at the rear of the base before For surface wiring entry a thin breakaway is provided along the base right edge Mount the receiver in the selected location For security use all four mounting holes two holes and two round holes provided in the base Affix the receiver Summary of Connections label to inside of the housing cover Setting the DIP switches All Receivers Set the receiver DIP switch 2 through 4 to the receiver address refer to the DIP switch in Figure 2 Verify that DIP switch 1 is in the OFF position Set DIP switch 5 according to the following chart SWITCH 5 Fire Applications Fire Applications to If multiple receivers are used on one control DIP 5 must be set to the same position on all DIP 5 during message reception For commercial fire DIP switch 5 must be in the ON Insert the wiring plug with 4 flying leads into the socket on the receiver see Figure 2 for socket Connect control keypad terminals see Wiring the SPECIFICATIONS section 4 wires Install the antennas in the right hand terminals of the terminal blocks at the upper edge of the circuit one into each block right hand terminal and the screws to secure them Avoid mounting the receiver antennas against metal surface Proceed with any programming of the control that be necessary for RF operation and the of the system wireless transmitters described in the control installation and setup guide the transmitter installation instructions The receiver can support up to 16 encrypted wireless keys The total quantity of wireless encrypted and unencrypted that can be used is by the control panel Wireless key buttons must be enrolled to zones in the panel via zone programming first If the key is to be used for arming and disarming VISTA 40 and up a user number must then be to the wireless key via user programming If is not done in this order you will be unable to successfully to the RF button zone number in user programming If more than one receiver is being used and you are encrypted wireless keys we recommend that apply power to only one receiver enroll your wireless keys into it and then remove from the receiver Repeat this process for each Only apply power to all receivers after the wireless keys have been enrolled into each The RED LED located on the receiver circuit board be used as an indicator of strong local radio interference If this LED is continuously the receiver should be relocated Replace the receiver cover KEYS receiver can support up to 16 encrypted wireless keys at one time If the number on the microprocessor is WAK 4406 4 or higher the provides you with the capability to check space and or delete encrypted keys using the procedures Space Available GREEN LED located on the receiver circuit board be used to determine how many more encrypted keys be enrolled into the receiver To determine how many encrypted keys may be enrolled Remove power from the receiver and set DIP

Related Files