Ademco - Agency Listing

File Preview
File Preview
Click below to download for free

File Data

Name ademco-agency-listing-6891234075.pdf
Type PDF
Size 39.21 KB
Downloads

Text Preview

Agency Statements Installation Requirements following requirements apply to both UL residential and UL commercial burglary installations All partitions must be owned and managed by the same person s All partitions must be part of one building at one street address The audible alarm device s must be placed where it they can be heard by all partitions The control cabinet must be protected from unauthorized access This can be done by installing a switch on the cabinet door supplied with VISTA 128FBP VISTA 250FBP or by installing a UL passive infrared detector positioned to detect cabinet access Wire the selected device to any zone Zone 1 8 Program this zone for day trouble night alarm type 05 or 24 hour alarm type 07 response The 24 hour alarm response must be used for multiple partitioned Remote downloading and auto disarming are not UL Listed features Local Fire at least one Notification Appliance Circuit for supervision and wire polarized fire alarm indicators it Program this circuit for temporal sounding Central Station and Remote Station Fire Size the backup battery for 24 hour standby central station or 60 hour standby remote station time For central station service you may use the 7720ULF or 7920SE LORRAs alone the main dialer with a or the main dialer with the 5140DLM Backup Dialer Module For remote station service you use the main dialer with the 5140DLM Backup Dialer Module When using the LORRA connect its channel inputs to the VISTA 128FBP VISTA 250FBP fire alarm supervisory if used and trouble triggers Also connect its XMIT OKAY output to Input 1 on the J2 header Program J2 Input 1 system Zone 973 for 24 hour trouble type 19 to send radio faults When the main dialer is used enable it field 3 30 and connect it to a telephone line Assign a 24 hour response type 19 to system Zone 974 to enable main dialer supervision The VISTA will activate the trouble trigger when it detects a main dialer supervision fault When the backup dialer is used install it on the VISTA 128FBP VISTA 250FBP PCB shield Enable it 3 30 and connect it to a separate telephone line Assign a 24 hour trouble response type 19 to Zone 975 to enable backup dialer supervision When the dialer is used program it to send fire alarm fire supervisory if used trouble AC loss low normal dialer test and off normal dialer test reports Field 27 must be set to 024 maximum that test reports are sent at least once every 24 hours If a secondary number is programmed set the maximum number of dialer re tries to 3 4 or 5 in field Grade A Local Mercantile Premises Local Mercantile Safe Vault Use the VISTA 128FBP VISTA 250FBP All zones must be configured for EOLR supervision 41 0 Wireless sensors may not be used If RPMs are used set field 24 to 0 to enable tamper detection Attach a door tamper switch supplied to the VISTA 128FBP VISTA 250FBP cabinet backbox For safe vault installations a shock sensor not supplied must also be attached to the backbox Also see the Cabinet in SECTION 3 Installing the Control Wire an ADEMCO AB12 Grade A Bell Box to the Notification Appliance Circuit Bell wires must be run conduit Program the Notification Appliance Circuit for 16 minutes or longer timeout and for of arming ding Also see SECTION 3 Installing the Control Wire the VISTA 128FBP VISTA 250FBP tamper switch and AB12 Bell Box tamper switches to any supervised zone zones 1 8 Program this zone for day trouble night alarm type 05 or 24 hour alarm type 07 response The 24 hour alarm response must be used for multiple partitioned Entry delays must not exceed 45 seconds and exit delays must not exceed 60 seconds Police Station Connected Burglar Alarm the instructions for UL609 local installations given above Grade A Service You may use the VISTA 128FBP VISTA 250FBP dialer alone or the 7720 Long Range Radio alone When using the dialer program it to send Burglary Alarm Low Battery and Communicator Test Field 27 must be set to 024 or less so that test reports are sent at least once every 24 hours using the 7720 connect it to the VISTA 128FBP VISTA 250FBP burglary audible panic alarm trigger Grade AA Service You must use a 7920SE Long Range Radio Connect the 7920SE to the VISTA 128FBP VISTA 250FBP burglary audible panic alarm trigger Central Station Burglary Alarm the instructions for UL609 local installations given above Grade A Service You must use the VISTA 128FBP VISTA 250FBP dialer with a 7720 Long Range Radio Connect the control burglary audible panic alarm trigger on J2 header to the 7720 Program a 24 trouble response for Zone 974 to enable main dialer supervision The VISTA 128FBP VISTA will activate the burglary audible panic trigger when a corresponding alarm is detected and activate the trouble trigger when a main dialer fault is detected Also connect the 7720 radio fault output to one of the VISTA 128FBP VISTA 250FBP EOLR zones i e 1 8 Program this zone for a trouble by day alarm by night type 05 or a 24 hour type 07 08 response to radio faults Program the control dialer to send Burglary Alarm Trouble Opening Closing and Low Battery Grade AA Service the instructions for Grade A service except use the 7920SE in place of the 7720 State Fire Marshal CSFM Requirements backup The California State Fire Marshal has published new regulations which require that all fire alarm control panels installed after June 30 1993 must be provided with a backup battery has sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the standby condition followed by at least 4 minutes in the intended fire alarm signaling condition Be to size the battery to meet this requirement COMMUNICATIONS COMMISSION FCC PART 15 STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio energy and if not installed and used in accordance with the instructions may cause harmful to radio communications However there is no guarantee that interference will not occur in a installation If this equipment does cause harmful interference to radio or television reception can be determined by turning the equipment off and on the user is encouraged to try to correct the by one or more of the following measures Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help the separation between the equipment and receiver THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS the event of telephone operational problems disconnect the control panel by removing the plug from the CA38A in Canada wall jack We recommend that you demonstrate disconnecting the phones on of the system Do not disconnect the phone connection inside the control panel Doing so will in the loss of your phone lines If the regular phone works correctly after the control panel has been from the phone lines the control panel has a problem and should be returned for repair If disconnection of the control panel there is still a problem on the line notify the telephone company it has a problem and request prompt repair service The user may not under any circumstances in or of warranty attempt any service or repairs to the system It must be returned to the factory or an service agency for all repairs PART 68 NOTICE RJ31X is used to connect this equipment to the telephone network equipment complies with Part 68 of the FCC rules On the front cover of this equipment is a label that among other information the FCC registration number and ringer equivalence number REN for equipment If requested

Related Files