Ademco - Quest 2240 Microwave-PIR Intrusion Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-quest-2240-microwave-pir-intrusion-detector-8157069324.pdf |
---|---|
Type | |
Size | 967.98 KB |
Downloads |
Text Preview
INSTALLATION INSTRUCTIONS INFORMATION Quest 2240 Microwave PIR motions offers next performance with technology advances in many including optics and signal processing Unmatched of operation are assured with the following advanced Microprocessor based C3 signal processing Cross Channel correlates data from both the PIR and channel for decision making rather than just separate alarms on each channel Accu Trak test feature allows the installer to determine coverage pattern of both PIR and microwave at the time as well as check environmental Automatic adaption to environmental disturbances Rejection with a patented digital notch filter of light disturbance Continuous supervision of both PIR and microwave Advanced dual slope temperature compensation assures at all temperatures detector is shipped with its standard wide angle lens to provide coverage of 40ft x 50ft If other coverage are desired please consider the following alternative Quest 2220 20ft x 25ft with 100lb pet immunity Quest 2235 35ft x 45ft with 100lb pet immunity Quest 2260 60ft x 75ft swivel mounting brackets are available under part 998SB and Quest SB2 2240 MOTION SENSOR 6 98 Method Dual technology Microwave PIR Pet Immune Lens x 50 12.2m x 15.2m Zones Pet Immune Lens 31 zones long range 7 over 7 intermediate over 4 short range optional look down zone Processing Standard or Intermediate via DIP switch Relay Rate Height 7 8ft 2.1 2.4m 7.5 ft 2.3m 15 3m sec Voltage 12V and Green LED LED INDICATIONS via DIP Switch A N C 28VDC 90ma max with protective resistor VDC with reverse polarity protection ma nominal non alarm ma nom alarm LED disabled ma nom alarm LED enabled ma nom during warm up source should be capable of at 4 hours of battery standby Temp 20OF to 122OF 29OC to 50OC to 50OC for UL installations to 95 RH max non condensing x 5.2 H x 2.2 D x 132m x 56m LOCATION CONSIDERATIONS protective patterns are shown in Figure 1 for a mounting height of 7.5 ft 2.3m The microwave pattern shown in Figure 1 represents coverage in space In practical applications when the detector is by ceiling floor and walls reflections can occur A MOUNTING LOCATION detector responds to changes in energy which occur when intruder moves into the combined protection pattern Best will be obtained if the mounting site is selected so the likely direction of intruder motion is generally across pattern and angles slightly toward the detector HINTS detector is remarkably resistant to false alarm hazards the following recommendation should be observed Never install the detector in an environment that causes alarm condition in one technology Good installations with both LEDs OFF when in the Accu Trak test and there is no target motion Do not mount on an unstable surface Locate the unit on a inside wall whenever possible Avoid sources of such as loose fitting doors and walls that shake heavy traffic exists Pattern Not Available 1 COVERAGE PATTERN Do not install on or close to metal structures such as metal frames shelves etc Do not include space heaters in the protective pattern possible to avoid rapid temperature changes vibrations from fans ALL microwave transmission penetrates most building except metal which reflects transmission objects outside of the protected area may be unless the microwave sensitivity control is kept as low a setting as possible to minimize penetration Make sure the detection area does not have obstructions screens large pieces of furniture plants etc may block the PIR portion of the coverage pattern the unit to a firm vertical surface The wall wiring hole be no more than 5 16 8mm diameter Remove the front cover by twisting a screwdriver blade in groove between cover and base at the bottom edge of case and then lifting the cover off Remove the circuit board from the base Loosen the adjustment screw slide the circuit board up and PCB holding tabs as shown in Figure 3 Breakout desired mounting entry holes Refer to Figure Knockout holes in the base are for normal surface on a wall Knockout holes are for corner Also break out the wire entry hole at this time X in Figure 2 Feed wiring unpowered coming from the wall through wire access hole near the top of the detector base Use wiring channel on the back to assist with routing Mount the base reinstall the PC board Vertically align PCB per Table 1before tightening screw Refer to WIRING CONNECTIONS section before the cover 2 BACK CASE STRIP BOARD TAB BACK TO BOARD LENS INPUT SUPPLY INPUT SUPPLY CONTACT N C COMMON CONTACT OUTPUT SUPERVISION shielded wire for UL installations LED PIN SENSITIVITY CLOCKWISE TO SENSITIVITY SCREW SWITCH LIGHT DETECTOR LIGHT 3 INTERIOR OF DETECTOR CONNECTIONS all wires through the wire access slot at the top of the base near the terminal block and connect to the screw See Figure 3 for wiring details Seal any openings in base with foam or RTV not supplied to prevent drafts and from entering the unit Apply power only after all have been made and are inspected Input Supply Power must be provided from a filtered source with 25ma capability and at 4 hours of standby battery capacity Input Supply ground Contact N C Open on Alarm Common Contact Switch N C Open on Tamper Output Upon supervision failure this open output will go low requires 1000 ohm pull up Use shielded wire for UL installations LED DISABLE separate terminal pin is provided on the PCB that can be to remotely control the LED See Figure 3 If a 7 16VDC is applied to the terminal all LED functions will be including alarm Accu Trak test mode and failures To remotely enable the LED by removing 7 16VDC signal DIP Switch 3 must be set to OFF LED Range 7.6m 9.1m 12.2m Position 8 4 0 1 PCB VERTICAL ADJUSTMENT For 7ft to 8ft mounting height AND SELECTIONS SENSITIVITY CONTROL the potentiometer clockwise to increase sensitivity SWITCH SETTINGS ON Accu Trak test mode relay open when selected Normal operation ON Intermediate signal processing Standard signal processing ON LED disable LED enable INDICATIONS INDICATIONS Up Red Green LEDs ON for 50 secs LED ON Green LED ON for microwave Mode Red LED flashes for PIR Red LED flashes for PIR failure LED flashes for microwave failure When Accu Trak test mode is selected alarm relay is held open to prevent leaving the detector in the mode PROCESSING OPTION Standard Signal Processing set DIP Switch 2 For Signal Processing set DIP switch 2 ON Use a pointed tool to move the switch handle Signal Processing This is the recommended for maximum false alarm immunity It tolerates extremes on this setting Signal Processing This is the recommended for any location where an intruder is expected to cover a small portion of the protected area It tolerates normal on this setting ENABLE DISABLE OPTION enable the LED set the DIP Switch 3 to OFF To disable LED set DIP Switch 3 ON Use a small pointed tool to the switch handle PROCEDURES power up testing must not begin until the LED after first applying power to signify warm up is about 50 seconds