Ademco - Via-30 Programming Form

File Preview
File Preview
Click below to download for free

File Data

Name ademco-via-30-programming-form-5198673024.pdf
Type PDF
Size 1.15 MB
Downloads

Text Preview

A dem co via 30 PROGRAMMING FORM Default Value ARMING 20 251 CODE ARM ENABLE SYSTEM lYPE 4 digits 0 9 4 none 1 5700 4281 2 5800 5881 BYPASS FUNCTION none 1 bypass open zones HOUSE ID CODE 0 0 enter 01 31 for 5700 System Enter also for 5827 keypad EXPANSION REIAY SOUNDS AND TIMING 28 38 none 1 2 4229 3.4204 ALARM SOUNDING ZONE SOUNDER TIMEOUT DISABLE t BELL TIMEOUT no 1 yes no 1 s yes DELAY Osec 45sec Delay ENTRY Delay sec PROGRAMMING 40 50 ACCESS CODE PHONE No PHONE No ACCT No l and press 41 Enter4 digits O 9 If fewerthan4 entered exit by entering next field To clear entries from field press l4rY not fill unused srraces If fewer than 12 digits entered exit by pressing l and press if entering next held To clear entries from field press l41 entering next eld To clear entries fro fewer than 12 dioits entered exit bv cwessina l and oress not fill unused soaces for E 15 for F Enter l as 4th digit if 3 1 dialer reporting is to be used If only digits used exit by pressing l and press next field To clear entries from field press l42 B 12forC 13 EnterO 9 ll For Acct No 1234 enter SYSTEM SELECT U FORMAT Cent Sta NOT on a WATS line on a WATS line Cent Sta Pulse Dial 1 Tone Dial Pulse Dial 3 Tone Dial 3 4 1 3 1 4 1 RADIONICS STANDARD 4 2 ADEMCO US STANDARD 4 2 RADIONICS STANDARD US STANDARD or undefined 4 2 ADEMCO EXPRESS ADEMCO CONTACT ID REPORTING 3 1 4 1 ADEMCO US EXPANDED 3 1 4 1 RADIONICS EXPANDED REPORTING report only Disable Restore Cancel except Open Close Test Restore Cancel except OpetiClose Test Test SEC DIALER DEIAY BURG TEST MESSAGE none 1 24 hours 2 weekly enter Test Code in field 64 Radionics B F reporting 1 SESCOA O 9 only reporting O for all other formats OF ARMING DING t 1 yes Entry of a number other than one specified will give unpredictable results 4 93 See Instructions N6667 ASSIGNMENT ALARM CODES explanation on next page RPT CODE INPUT Zone Numbers Zn 10 17 to 4219 4229 Auxiliary Wired Loops A H can use Zn 10 63 if 4219 4229 IS NOT used Zn 18 63 if 4219 4229 IS used used rl rrm ON CONTROL 1 4 are not present Zone 5 Zone 6 Panic 3 9 4229 LOOP A 2nd St 1 1 1 I 1 I I I 1 1 1 1 1 THE ZONE NUMBER Nos are from 05 to 63,95,96 Field sat for auxiliary wired loops 4219 or 4229 use Zone Nos 10 17 for loops A H Field set for RF 5700 or 5600 use Zone NOS 18 63 if 4219 4229 are pre assigned ALSO used ZONE TYPE 10 63 if 4219 4229 is NOT used NotUsed Entry Exit Not Used Perimeter Interior Follower Trouble Day Alarm Night 24 Hr Silent HrAux Fire Audible ALARM REPORT CODE Hex Digits each Hex Digit enter Disaml m Interior w Delay Arm Stay Arm Away No Alarm Response for O 9 10 for A 11 for B l 2 for C for D 14 for E 15 for F is entered in the first box there will be no report for hat zone contact ID reporting this is enabling code only Enter any digit other than O in the first box second box is ignored LOOP Hard Wire Aux Wire 4219 or 4229 3 for RF Supervised RF 4 for UR Unsupervised RF 5 for BR Button Type RF LEARNED RF INPUT Used with self learning 58W RF Loop Input Devices Record transmitter input number a 3 1 or 4 1 Standard Format Enter a code in the box 1 9 0 B C D E or F Enter for O 1 for B for C for D for E for F 10 in the first box will disable a report not in the second box will result in automatic to the next field when programming 4 2 Format codes in both an Expanded 1st and 2nd digits for 1 9 0 or B F as described above 0 not in the secorxfbox will eliminate the expanded for that report not O both boxes will disable the report Ademco Contact ID Reporting Enter any digit othel in the first box to enable zone to report entries in the boxes will be ignored rrot in the first box will disable the report For Code 3 Single Digit enter Code 32 Two Digits enter Code B2 Hexadecimal enter STATUS REPORT CODES REPORT CODE REPORT CODE LOSS REPORT CODE BAITERY REPORT CODE REPORT CODE REPORT CODE REPORT CODE 2nd digit is automatically sent as the user number if or 4 2 reporting is selected XMTR LOW BAT REPORT CODE REPORT CODE CODES 69 75 RESTORES for TROUBLE LOW BAT BYPASS yes report after all zones restored not applicable to Contact reporting

Related Files