Ademco - Vista 10 Installation Manual (UK)

File Preview
File Preview
Click below to download for free

File Data

Name ademco-vista-10-installation-manual-uk-9140275386.pdf
Type PDF
Size 1.09 MB
Downloads

Text Preview

VISTVISTVISTVISTVISTA 10 UK 10 UK 10 UK 10 UK 10 UK 1 SAFETY INSTRUCTIONS 5 5 5 5 5 6 Supply Connections 6 Type 7 Rating 7 7 Statement 8 2 INSTALLING THE VISTA 10 9 Procedure 9 of Main PCB Connections 10 12 Information 12 12 Line Wiring 13 14 14 14 of Installation 14 3 PROGRAMMING THE VISTA 10 17 17 Exiting Program Mode 17 Format 17 17 Version 17 Fields 18 18 Options 18 19 Programming Options 19 20 22 4 INSTALLATION SERVICE NOTES 23 Reset 23 Bypassing Isolating Zones 23 User Codes 23 View Event Log 23 Set Real Time Clock 23 Communication Test 23 Troubleshooting 24 LIMITED WARRANTY 25 1 SAFETY read this section carefully is essential that this product is installed correctly in particular with respect to safety connection of the mains electricity supply and connection to the Switched Telephone Network PSTN product is not suitable for installation maintenance or connection by the user and maintenance must be carried out by a competent qualified installer to the requirements of the relevant public telecommunications operator is a condition of the product approval that the installer complies with the follow control must be sited internally in a secure area where it cannot be readily inter with but in a location where there is adequate ventilation ample light and is accessible for servicing and maintenance It is not suitable for siting exter or in harsh environments where it could be subject to high humidity extremes temperature chemical atmospheres high dust levels or in a position where it may subject to dripping of or splashing with water or other fluids control must be securely fixed to a vertical smooth solid surface which is part of fabric of the building The position chosen must allow the cabinet door to be and allow unhindered access for installation and maintenance Remove cabinet lid by loosening the top two screws open the top then lift off from the lip Decide on the cable entry positions refer to cabling section and remove at this point Using the template provided mark the three fixing hole on the wall Drill and plug a solid wall and fit the top fixing screw recom 1.5 x No 8 minimum 1mm proud of the surface Hang the control cabinet means of the keyhole fixing and fit the remaining two screws securely In case of walls use proper toggle or butterfly fixings the control has been designed so that no part attains an unsafe temperature it important that adequate ventilation is provided around the cabinet It is important that other heat radiating equipment or sources of heat are not positioned to the cabinet product has high voltage barriers between the mains supply excessive voltage alarm wiring terminals safe extra low voltage and the telephone line terminals network voltage Each control is individually tested before it leaves the to ensure the integrity of these barriers It is essential that these barriers are in the way the cables enter the cabinet are routed inside the cabinet and externally The routing of the cables as shown in the diagram must be fol precisely rear entry points and a trunking entry point is provided for cable entries holes must not be cut in the enclosure Where necessary the cable must protected at the entry point by the use of grommets The cables external to the must be either firmly affixed to the fabric of the building using suitable clips saddles or mechanically protected in conduit or trunking Alarm system cables not be allowed to loop inside the cabinet they must be trimmed as shown must not be possible to put strain on the wiring within the control cabinet by on cable external to the cabinet or the trunking entry point must only be removed if cables are to enter the at that point The hole must be covered by the trunking or conduit or by of a blanking grommet must not be possible to push a finger or similar size object or instrument into any or cable entry point Supply Connections THIS APPARATUS MUST BE EARTHED to the mains supply must be made by a competent qualified person NICEIC approved in accordance with the current IEE and local supply regu The earth impedance of the mains input earth must be verified means of isolation from the mains supply must be provided within 2 metres of the This is normally a switched fused spur fitted with a 3 amp fuse a flexible cable is connected to the control having cores coloured green and brown and blue it is important to connect the wires according to the follow code Earth connect to terminal marked E Neutral connect to terminal N a non flexible cable is connected to the control having cores coloured red and a green and yellow sleeve covering the earthing conductor

Related Files