Ademco - Vista 100 Addendum
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-vista-100-addendum-0298546137.pdf |
---|---|
Type | |
Size | 936.46 KB |
Downloads |
Text Preview
ADDENDUM TO INSTALLATION INSTRUCTIONS WITH ISSUE 5881EH wireless receiver and 5808 smoke detector are now listed for use in commercial fire These features are pending CSFM approval The following provisions apply Program fields 1 30 and 1 31 currently state that the supervision period for the wireless receiver transmitters must be no longer than 6 hours This should be no longer than 4 hours program of 2 for commercial fire applications On page 141 of the Vista 100 Installation Instructions zones 989 and 991 are stated to be the zones for receivers 1 and 2 Actually each receiver supervisory zone is equal to 8 two digit device address of the receiver For example if the receiver is set to device address the receiver supervisory zone would be 805 The supervisory zone must be programmed for trouble zone type 19 990 and 988 are used to supervise the RF reception of receivers 1 and 2 respectively zones must be programmed for a response type of 24 hr Trouble zone type 19 A fault on of these zones indicates that receiver has detected a condition that may impede proper RF reception i e jamming other RF interference receiver has not received any RF messages in the time period defined by program 1 30 In this case the fault would be accompanied by a supervision fault for one or more transmitters as well DIP Switch 5 on the 5881EH receiver must be set to ON for commercial fire applications see below 5881EH receiver must be mounted in a metal enclosure for commercial fire applications mounting in the enclosure DO NOT use the antenna grounding lugs Additionally you must an insulating washer supplied between the head of each screw and the PC board see figure WHEN CIRCUIT BOARD IS MOUNTED IN CABINET GROUNDING LUGS 2 MUSTBE INSERTED IN LEFT HAND OF ANTENNA BLOCKS AND TO CABINET SEE RECEIVER AND INSTRUCTIONS BOARD IS MOUNTED IN A SEPARATE CABINET REQUIRED IN FIRE APPLICA DO NOT USE THE LUGS IN No IS ON BOARD SWITCH HOLES RELEASE CIRCUIT BOARD SCREWS 2 AND BEND TABS 2 USE THESE WITH INSULATING BENEATH THE TO MOUNT BOARD IN CABINET FOR COM FIRE APPLICATIONS RECEIVER INSTRUCTIONS SWITCH POSITION 5 PRESENT ONLY ON 5881EH 5881EH FOR USE IN COMMERCIAL FIRE SEE THE RECEIVER INSTRUCTIONS USE IN NON COMMERCIAL FIRE INSTALLATIONS FOR COMMERCIAL FIRE APPLICATIONS THE 5881EH PC MUST BE MOUNTED IN A SEPARATE CABINET SEE INSTRUCTIONS FOR DETAILS FOR CONTROL REMOTE CONNECTION EACH RECEIVER BE ON INDIVIDUAL RUN MAX OF 220 FT 67M 22 0.64MM WIRE OR FT 168M OF 18 1MM FOR EACH RUN 20 MAX IN COMMERCIAL INSTALLATIONS SEE INSTRUC SWITCH WHITE AREAS SWITCH HANDLES 2 DETERMINE RECEIVER ADDRESS CONTROL INSTRUCTIONS ADDRESS TO USE DIP SWITCH SHOWN SET FOR ADDRESS SWITCH POSITION 5 PRESENT ON 5881EH ONLY CHART BELOW ADDRESS SETTINGS means PRESENT ONLY ON 5881EH SEE TEXT AT LEFT ON ON ON ON ON ON ON ON ON ON ON ON FUTURE USE Note regarding Duress enable the Duress feature make sure you complete the following steps Enable Duress for each partition in program field 85 Enter a report code for zone 992 the feature will not work if a report code is not programmed Other Side 10 96 following is an updated alpha vocabulary for the Vista 100 control Words annunciated by the VIP module are highlighted in bold text Word Space 001 AIR 002 ALARM ALCOVE ALLEY AMBUSH ANTENNA 007 AREA 008 APARTMENT ART 010 ATTIC AUDIO AUX AUXILIARY 014 BABY 015 BACK 016 BAR BARN 018 BASEMENT 019 BATHROOM 020 BED 021 BEDROOM BELL BELL 1 BELL 2 025 BLOWER 026 BOILER BOTTOM BOX BREAK 030 BUILDING BURNER CABINET 033 CALL CAMERA CAR CASE CASH CCTV CEILING CELLAR 041 CENTRAL CIRCUIT CLIP 044 CLOSED COIN COLD COATROOM COLLECTION COMBUSTION 050 COMPUTER CONTACT 052 DAUGHTERS DELAYED 054 DEN DESK 056 DETECTOR DIALER 1 DIALER 2 059 DINING DISCRIMINATOR DISPLAY DOCK 063 DOOR DORMER 065 DOWN 066 DOWNSTAIRS DRAWER 068 DRIVEWAY DRUG 070 DUCT 071 EARTH EAST ELECTRIC EMERGENCY ENTRY 076 EQUIPMENT EXECUTIVE 078 EXIT EXTERIOR 080 FACTORY FAILURE FAMILY 083 FATHERS 084 FENCE FILE 086 FIRE 087 FLOOR FLOW FOIL 090 FOYER FREEZER 092 FRONT FUR FURNACE GALLERY 096 GARAGE 097 GAS GATE 099 GLASS GROUND GUEST GUN 103 HALL 104 HEAT HIGH HOLDUP HOUSE INFRARED 109 INSIDE INTERIOR INTRUSION JEWELRY 113 KITCHEN 114 LAUNDRY 115 LEFT LEVEL 117 LIBRARY 118 LIGHT LINE LIQUOR 121 LIVING 122 LOADING LOCK LOOP LORRA LOW 127 LOWER 128 MACHINE MAGNETIC MAIDS MAIN 132 MASTER MAT 134 MEDICAL MEDICINE MICROWAVE MONEY MONITOR 139 MOTHERS 140 MOTION MOTOR MUD 143 NORTH NURSERY 145 OFFICE OIL 147 OPEN OPENING 149 OUTSIDE OVERFLOW OVERHEAD PAINTING 153 PANIC PASSIVE 155 PATIO PERIMETER 157 PHONE PHOTO POINT POLICE POOL 162 POWER QUAD RADIO 165 REAR RECREATION REFRIG REFRIGERATION RELAY 1 RF 171 RIGHT 172 ROOM ROOF SAFE SCREEN SENSOR 177 SERVICE 178 SHED SHOCK 180 SHOP SHORT SHOW 183 SIDE SKYLIGHT SLIDING 186 SMOKE SONIC 188 SONS 189 SOUTH SPRINKLER STAMP 192 STATION STEREO STORE 195 STORAGE STORY STRESS STRIKE SUMP SUPERVISED SUPERVISION SWIMMING SWITCH TAMPER TAPE TELCO TELEPHONE TELLER 209 TEMPERATURE THERMOSTAT 211 TOOL TRANSMITTER TRAP TRIGGERS ULTRA 216 UP 217 UPPER 218 UPSTAIRS 219 UTILITY VALVE VAULT VIBRATION VOLTAGE WALL WAREHOUSE WASH 227 WEST 228 WINDOW WINE 230 WING WORK XMITTER YARD ZN 1 235 ZONE 0 1 1ST 2 2ND 3 3RD 4 4TH 5 5TH 6 6TH 7 7TH 8 8TH 9 9TH Custom Word 1 Custom Word 20 ASCII CHART Adding Custom Words DEVICE MANUFACTURING CO DIVISION OF PITTWAY CORPORATION Eileen Way Syosset New York 11791 1996 10 96