Ademco - Vista 10SEa Programming Form (Australian)

File Preview
File Preview
Click below to download for free

File Data

Name ademco-vista-10sea-programming-form-australian-3926018754.pdf
Type PDF
Size 781.18 KB
Downloads

Text Preview

9,67 cid 16 cid 20 cid 19 6 D 12 99 of Contents Form 3 of Programming 7 Programming Information 7 the Programming Mode 7 a Data Field 8 a Data Field Erasing an Entry in a Data Field 8 Menu Mode Programming Q 56 Q 80 Q 81 Q 82 Q 83 8 Factory Defaults 8 System Setup Fields 9 the Programming Mode 9 1 5800 Series Transmitter Input Loop Identification 10 Vocabulary List For Entering Zone Descriptors 11 ASCII Chart For Adding Custom Words 12 Response Type Definitions 13 Field Descriptions 15 Programming and Control Downloading 22 Information 22 Required 22 Programming Information 22 Programming Advisory Notes 23 of Connections Diagram Inside Back Cover 2 PROGRAMMING FORM programming requires the use of a 2 line alpha keypad e g 6139 connected to the keypad terminals on the control set all programme fields to ADEMCO default values Key T 97 VALUES Default Value RELAY 0 none 1 4219 2 4229 3 4204 0 MODULE ACCESS CODE FUNCTION SETUP 20 27 CODE ARM ENABLE SYSTEM TYPE ARM ENABLE HOUSE ID CODE TO ALTERNATIVE MEDIA ACM 0 SOUNDS AND TIMING 28 39 ALARM SOUNDING ZONE SOUNDER TIMEOUT TIMEOUT DELAY 4 digits 0 9 4 1 1 1 no 1 yes 0 0 1 0 0 0 0 none 2 5800 System 5881 6128 RF type rcvr none 1 auto bypass open exit route zones prior to arming enter 01 31 for 5827 5827BD Keypad if used in 5800 system digit Enter 1 2nd digit Enter only 11 for 12 for in either position disabled no 1 yes If yes selected dialler reports to PRIMARY No field 47 also be sent via ACM All dialler and ACM reports will be in Contact ID overriding field 46 selection 0 no 1 yes 0 0 2 2 fire sounder timeout 1 no fire sounder timeout none 1 4 min 2 8 min 3 12 min 4 16 min 0 sec 1 20 sec 2 30 sec 3 45 sec 4 60 sec 5 90 sec Delay ENTRY Delay 15 sec EXIT WARNING 0 no 1 yes PROGRAMMING 40 50 NOTE In fields 40 41 and 42 Enter 0 9 11 for 12 for 13 for pause ACCESS CODE PHONE NO PHONE NO up to 4 digits if PABX code is needed to access an outside line If fewer than 4 entered do not fill unused spaces exit by pressing T and press 41 if entering next To clear entries from field press T 40T up to 12 digits If fewer than 12 digits entered exit by pressing T and press 42 if next field To clear entries from field press T 41T up to 12 digits If fewer than 12 digits entered exit by pressing T and press 43 if next field To clear entries from field press T 42T ACCT NO IS ALSO THE ACM SUBS ACCT NO Enter 0 9 11 for B 12 for C 13 for D 14 for E 15 for F Enter 0 as the first of a 4 digit account number for Nos 0000 0999 End field by pressing T and press field FFFF For Acct No 1234 enter Acct No B234 enter Entry of a number other than one specified will give unpredictable results 3 SYSTEM SELECT 0 FORMAT REPORTING Pulse Dial 1 Tone Dial 0 see field 27 ADEMCO Contact ID ADEMCO Local Audio SEC DIALLER DELAY BURG TEST MESSAGE OF AWAY ARMING 3 RESPONSE TO OPEN 0 0 no 1 yes 0 0 0 0 Disable Backup report only PRIMARY PHONE NO Alarms Restore Cancel All Reports except Open Close Test Alarms Restore Cancel All Reports except Open Close Test All Reports 0 Reporting SECONDARY PHONE NO Reports Test Reports Reports Reports none 1 24 hrs 2 wkly 3 28 days Enter Test Code in field 64 no 1 yes 2 yes but with RF arming only 400mS nominal 1 10mS nominal Entry of a number other than one specified will give unpredictable results RPT CODE Hex INPUT ASSIGNMENT ALARM REPORT CODES explanation on next page Wired Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Duress Panic T or B Panic 1 T or A Panic 3 or C EXPANSION ZONES With 4219 or 4229 up to 8 wired zones available EXPANSION ZONES With 5881L up to 8 RF expansion zones available 5881M or 5881H up to 16 or RF Expansion Zone RPT CODE Hex FOR ONLY INPUT 4 DESCRIPTION ZONE ZONE 9th RPT CODE INPUT RF INPUT Hex ZONE TYPE ALARM REPORT CODE X P L A N A T I O N OF Z O N E A S S I G N M E N T T A B L E ZONE NUMBER With Field 22 set for RF use Zone Nos 10 63 Zone Not Used Entry Exit Do not use Perimeter Interior Follower Trouble Day Alarm Night 24 Hr Silent 24 Hr Audible 24 Hr Aux Fire Interior w Delay Arm Nos are from 01 to 63 95 96 Some are pre assigned Arm Disarm No Alarm Response 20 21 22 used for 5800 RF systems only Hex Digits For each Hex Digit enter 00 for 0 10 for A 11 for B 12 for C 13 for D 14 for 15 for F If 00 is entered in the first pair of boxes there will be no report for that zone Contact ID reporting this is an enabling code only M

Related Files