Ademco - Vista 128FB Programming Form
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-vista-128fb-programming-form-3261974580.pdf |
---|---|
Type | |
Size | 1.19 MB |
Downloads |
Text Preview
VISTA 128FB Fire Burglary Security System Scheduling Start Guide 5 98 2 Of Contents PROGRAMMING PROCEDURE 4 FIELD CATEGORIES 6 PROGRAMMING FORM 7 PROGRAMMING FORM 13 WITH 93 MENU MODE 15 LAYOUT WORKSHEETS 17 RELAYS WORKSHEETS 29 DESCRIPTOR VOCABULARY 32 VOICE DESCRIPTORS AND CUSTOM WORD SUBSTITUTES VOCABULARY 33 MENU PROMPTS 34 WORKSHEETS 35 SERIES RF TRANSMITTER LOOP DESIGNATIONS 40 SUMMARY OF CONNECTIONS 43 purpose of this document is to provide a quick and easy way to program your entire system A recommended procedure is included followed by a list of program fields with the corresponding program group they to system wide partition specific scheduling etc Two program forms are included one contains all the fields and the other contains the partition specific fields If you are setting up a single partition the partition specific fields become system wide fields the program forms are system layout worksheets We recommend that you use these sheets to plan system before programming is performed If you need further information about specific programming see the VISTA 128FB INSTALLATION INSTRUCTIONS Make sure that one two line alpha keypad is connected to the control and is set to device address 00 Partition System The system default is for a single partition system Use the VISTA 128FB SINGLE PARTITION FORM when programming for single partition usage Follow the steps outlined in PROGRAMMING PROCEDURE of this document for proper programming procedure System You must enter the number of partitions you are using in data field 2 00 to set the system for multiple Use the VISTA 128FB SINGLE PARTITION and the PARTITION SPECIFIC PROGRAM when programming the system for multiple partitions Follow the steps outlined in PROGRAMMING PROCEDURE of this document for proper programming procedure OF PROGRAMMING COMMANDS To enter program mode enter installer code 8 0 0 0 To set standard defaults press 97 To set communication defaults press 94 one of the following 80 low speed 81 Ademco Express High Speed 83 Ademco Contact ID To change to next page of program fields press 94 To return to previous set of fields press 99 To erase account phone number field entries press field number To assign zone descriptors press 93 follow menu prompts To add custom words press 93 follow menu prompts To enter Installer Message press 93 follow menu prompts To exit program mode press 99 OR 98 99 allows re access to programming mode by installer code 98 re access to programming mode by installer code default 97 values are shown in brackets otherwise default 0 Programming Procedure following is a step by step procedure recommended for programming your VISTA 128FB 1 Set the keypads and other peripheral devices to the appropriate addresses 2 Set factory defaults by pressing 97 will automatically enable keypad addresses 00 01 so be sure at least one keypad is set one of these addresses 3 Program system wide global data fields the programming form as a guide enter program mode and program all system wide fields These options affect the entire system regardless of partitions They control options downloader and dialer options RF options event logging options etc to the COMPLETE LIST OF PROGRAMMING FIELDS for a listing of the program fields by function that field 2 00 number of partitions field 1 32 RF expander type must be before continuing 4 Program partition specific fields the system wide fields have been programmed program all partition specific fields by first pressing 91 to select a partition while still in data field program Then enter the first partition specific field number 09 The next partition specific field automatically be displayed when you are finished entering the value for field 09 Partition fields can have different values for each partition To program the fields for the next press 91 enter the desired partition number then enter field 09 Refer to the OF PROGRAMMING section in the VISTA 128FB INSTALLATION for detailed instructions 5 Use 93 Menu Mode for device programming to the DEVICE PROGRAMMING section to assign keypad ID numbers and default for each keypad and to selectively suppress certain keypad sounding options Also this mode to assign RF receivers relay modules the VIP module the ecp Long Range and the Vista Gateway Module 6 Use 93 Menu Mode for zone programming to the ZONE PROGRAMMING section to program zone response types assign right zones and wireless zones assign zones to partitions and to program alarm report codes 7 Use 93 Menu Mode for programming relays to the RELAY PROGRAMMING section to program desired relay operation 8 Program Communication options to the COMMUNICATION PROGRAMMING section for further instructions to load defaults and to program related fields Then use 93 mode to program report if necessary 9 Use 93 Menu Mode for programming alpha descriptors to the ALPHA PROGRAMMING section to enter zone and partition descriptors and a installer message Use 93 Menu Mode for relay voice descriptors and custom word substitutes to the RELAY VOICE DESCRIPTORS section for further instructions for programming descriptors to be annunciated by the VIP module as well as the CUSTOM INDEX for custom word substitutes Use 80 Mode for programming schedules to the SCHEDULING section to program open close schedules temporary and holiday limitation of access schedules and time driven events Define user access codes to SECURITY ACCESS CODES section to program authority level O C reporting partition assignments and wireless key assignments for each user Exit Programming Mode programming mode by pressing either 98 or 99 Additional entries of 99 is required if exit is being done from fields 1 00 and above prevent re access to programming mode using the Installer code use 98 The only way re access programming mode is by depressing both the and keys at the same time 30 seconds of power up by using 99 always allows reentry into programming mode using the Installer code way of exiting will allow access via downloading Note that if local programming lockout set via downloading programming mode cannot be entered at the keypad Field Categories the following pages the programming fields have been arranged by category Use this index to cross reference numerical ordered fields on the programming form Group