Ademco - Vista 15 Programming Form

File Preview
File Preview
Click below to download for free

File Data

Name ademco-vista-15-programming-form-7928603415.pdf
Type PDF
Size 1.25 MB
Downloads

Text Preview

9,67 cid 16 cid 20 cid 24 4 00 2 programming requires the use of a 2 line alpha keypad connected to the terminals on the control Function Default Value Values Function Default Value Programmed Values SETUP Q 20 Q 30 27 X HOUSE CODE A 1 B 2 C 3 D 4 E 5 F G 7 H 8 I 9 J 10 K 11 L 12 M 13 N 14 O 15 P 28 PHONE MODULE ACCESS CODE digit enter 1 2nd digit enter 11 for Q 12 for 0 for either digit disables code 29 OUTPUT TO LONG RANGE RADIO disable enable Trouble code 1 B 11 12 D 13 E 14 or F 15 2nd digit of Trouble Dialer Report is entered from field Q 60 0 for UL 30 HARDWIRE SHORT DETECTION enable 0 disable 20 INSTALLER CODE 4 digits 0 21 QUICK ARM ENABLE enable 0 disable 22 RF SYSTEM 1 1 2 none 1 5800 5881 5882 5800 w RF Jam Detection 23 FORCED BYPASS none 1 bypass open zones for UL installations 24 RF HOUSE ID CODE disable all wireless keypad usage using 5827 5827BD and 5804BD 25 WIRED ZONE EXPANSION none 1 4219 2 4229 3 4204 26 CHIME BY ZONE no 1 yes program zones to chime zone list 3 SOUNDS AND TIMING Q 31 Q 39 31 SINGLE ALARM SOUNDING ZONE 35 ENTRY DELAY 1 zone type 01 yes 0 no 0 for UL installations 32 FIRE SOUNDER TIMEOUT timeout 1 no timeout 33 ALARM BELL TIMEOUT none 1 4 min 2 8 min 3 12 min 16 min 1 4 min minimum for UL 30 1 45 2 60 3 90 4 120 180 6 240 45 sec max for UL installations 36 ENTRY DELAY 2 zone type 02 30 1 45 2 60 3 90 4 120 180 6 240 45 sec max for UL installations 37 AUDIBLE EXIT WARNING 34 EXIT DELAY in seconds no 1 yes 120 180 240 30 45 60 90 sec max for UL installations Due to the Exit Restart feature set for 30 seconds 38 CONFIRMATION OF ARMING DING no 1 yes wired keypads and RF yes RF only 39 POWER UP IN PREVIOUS STATE no 1 yes 1 for UL installations Entry of a number other than the one specified will give unpredictable results PROGRAMMING Q 40 Q 52 fields Q 40 Q 41 Q 42 enter up to the number of digits shown Do not fill unused spaces Enter 0 11 for Q 12 for 13 for a 2 second pause 41 PRIMARY PHONE NO 40 PABX ACCESS CODE 6 digits If fewer than 6 digits are entered exit pressing Q and press 41 if entering next field clear entries from field press Q 40Q up to 20 digits do not fill unused spaces If fewer 20 digits entered exit by pressing Q and press if entering next field To clear entries from field Q 41Q 3 42 SECONDARY PHONE NO up to 20 digits Do not fill unused spaces If than 20 digits entered exit by pressing Q and 43 if entering next field To clear entries from press Q 42Q 43 PRIMARY SUBSCRIBER ACCOUNT NUMBER 15 15 15 44 SECONDARY SUBCRIBER ACCOUNT NUMBER fields Q 43 and Q 44 0 11 for B 12 for C 13 for D 14 for E 15 for F Enter Q as 4th digit if 3 1 reporting is to be used If only 3 digits used by pressing Q and press next field clear entries from field press Q 43Q or Q 44Q Acct 1234 enter 1 2 3 4 Acct B234 enter 2 3 4 45 PHONE SYSTEM SELECT Cent Sta IS NOT on a WATS line 0 Pulse Dial Tone Dial if Cent Sta IS on a WATS line 2 Pulse 3 Tone Dial 46 REPORT FORMAT 3 1 4 1 ADEMCO L S STANDARD 3 1 4 1 RADIONICS STANDARD 4 2 ADEMCO L S STANDARD 4 2 RADIONICS STANDARD or undefined 4 2 ADEMCO EXPRESS ADEMCO CONTACT ID REPORTING 3 1 4 1 ADEMCO L S EXPANDED 3 1 4 1 RADIONICS EXPANDED 47 SPLIT DUAL REPORTING Disable Backup report only PRIMARY PHONE No SECONDARY PHONE No Alarms Restore Ca n c e l All except Open Close T e s t Alarms Restore Canc el All except Open Close Test A l l Test l l l l l l All except O p e n Close PRIMARY PHONE No TO PAGING No Secondary Open Close for users Troubles Troubles Open Close for users Troubles Cl o s e f o r u s e rs 5 All report s All report s All e xc e p t Open Close Will report users 5 16 and if using wireless button type will report the zone number of the arm or disarm 10 25 Open Close for users 1 4 are not reported Installation Instructions for an explanation of the paging 48 DIALER DLY BURG FIRE in sec no 1 15 2 30 3 45 4 60 120 0 for UL installations 49 PERIODIC TEST REPORT none 1 24 hours 2 weekly 3 30 days Test Code in field Q 64 50 TEST REPORT OFFSET 24 hour 1 6 hours 2 12 hours 3 18 Time to 1st report from programming or 51 SESCOA RADIONICS SELECT Radionics 0 9 B F reporting 1 SESCOA 9 only reporting Select 0 for all other formats 52 CANCEL VERIFY no 1 yes Entry of a number other than the one specified will give unpredictable results 56 Q 58 ZONE ASSIGNMENT ALARM REPORT CODES field is an interactive mode Fill in the required data on the worksheet below and on next page and follow the programming procedure in installation manual Zone Types are shown on page 6 of this manual ON CONTROL explanation of headings on next page RPT CODE Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 1 can be used as a 2 wire Fire zone 4 00 00 00 00 00 00 1 1 1 1 1 1 Module Suprvsn Panic 1 Q Panic 3 Panic Q ZONES Assign zone numbers Zn 10 to 4219 4229 Auxiliary Wired Loops A if used zones can use zone numbers Zn 10 RPT CODE Loop A 1st Exp Zone RF Zones Zones 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FOR ONLY LEARNED RF INPUT

Related Files