Ademco - Vista 20 Programming Form

File Preview
File Preview
Click below to download for free

File Data

Name ademco-vista-20-programming-form-0138942657.pdf
Type PDF
Size 1.29 MB
Downloads

Text Preview

VISTA 20 SYSTEM changes in this issue are indicated by margin lines See Instructions programming use of a 2 line Alpha keypad connected partition keypad terminals the control For UL installations system maybe a single partition Values Default Value ARM ENABLE no 1 yes 4 digits O 9 4 11 2 none 1 5800 5881 5882 none 1 bypass open zones for UL installations 1 t 1 t 2 to 2 to Enter 01 31 if using 5827 keypad 2 RF House Code Entered Part 1 Code 1 none 1 4219 2 4229 3 4204 M 13 N A 1 B 2 C 3 D 4 K ll L 1 only 1st digit enter 1 9 2nd digit enter 11 for 12 for Default 00 no Voice Module enable enter Trouble code 1 B 11 14 or F 15 The 2nd digit of Trouble Dialer Report 1 to enable from field 60 for UL installations to disable 12 D 13 SETUP 2G 30 CODE SYSTEM BYPASS HOUSE ID CODE ZONE EXPANSION HOUSE CODE MODULE ACCESS CODE TO LONG RANGE RADIO ENABLE ZONE 7 SOUNDS AND TIMING 3 Y138 ALARM SOUNDING ZONE yes no for UL installations SOUNDER TIMEOUT timeout 1 no timeout BELL TIMEOUT none rein 2 8 rein 3 12 min 4 min minimum for UL TYPE 01 ENTRY DELAY EXIT WARNING sees O 1 20 sees sees 4 60 sees 5 90 sees Type 02 Entry Delay Zone Type 01 Delay 30 sees Delay Zone Type 01 Entry Delay 40 sees no 1 yes 1 t 1 t max UL installations 2 to 2 to OF ARMING DING no 1 yes 1 t 2 to UP IN PREVIOUS STATE PROGRAMMING 40 53 fields 40 41 42 enter up to the number of digits shown Do not fill unused spaces Enter O 9 11 for 12 for for a pause for UL installations no 1 yes ACCESS CODE fewer than 4 digits are entered exit by entering next field To clear entries from field 4 digits and press 41 I up to 12 digits not fill unused spaces press 42 up to 12 digits not fill unused spaces press 43 RECEIVER fewer than 12 digits entered exit by pressing entering next field To clear entries from field press 41 fewer than 12 digits entered exit by pressing entering next field To clear entries from field press 42 RECEIVER PHONE No PHONE No SUBS ACCT PART 1 SUBS ACCT PART 1 SUBS ACCT PART 2 SECONDARY SUBS ACCT PART 2 1 RECEIVER RECEIVER Entry of a number other than one specified give unpredictable as 4th digit O 9 1 1 for B 12 for C 13 for D 14 for E 15 for F only 3 digits exit by pressing and press next field clear entries from field press 43 44 to be used 3 1 dialer 6 Acct No 1234 enter Acct No B234 enter 11121314 Acct No 123 enter mzmzl SYSTEM SELECT Sta Cent Sta A OTona WATS line on a WATS line FORMAT PRIMARY SECONDARY Pulse Dial Tone Dial Pulse Dial Tone Dial U U or undefined 4 2 ADEMCO EXPRESS ADEMCO CONTACT ID REPORTING 3 1 4 1 ADEMCO W EXPANDED 3 1 4 1 RADIONICS EXPANDED 3 1 4 1 ADEMCO L S STANDARD 3 1 4 1 RADIONICS STANDARD 4 2 ADEMCO IJS STANDARD 4 2 RADIONICS STANDARD Disable Backup report only PRIMARY Alarms Restore Cancel All except Open Close Test Alarms Restore Cancel All except Open Close Test All SECONDARY Test I I I REPORTING SEC DIALER DELAY BURG no 1 yes for UL installations TEST REPORT REPORT OFFSET none 1 24 hours 2 weekly 3 30 days Test Code in field 24 houv 1 6 hours to 1st report 12 hours 3 18 hours downloading programming Reports with Partition 1 subscriber No Radionics O 9 B F reporting 1 SESCOA O 9 only reporting O for all other formats Entry of a number other than one specified will give unpredictable results ASSIGNMENT ALARM below and on next page and follow the programming CODES field is an interactive mode Fill in the installation manual the required data on the ON CONTROL RPT CODE explanation of headings on next page m Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 t Zone 8 Module Panic 1 or A Panic 3 or C Panic or B ml 9 4229 Loop A Exp Zone 1 can be used as a 2 wire Fire zone 7 can be used for optional Keyswitch shows as 77 for Zone Type iT 8 can be used as a Glassbreek zone ZONES Zone Numbers Zn 10 17 to 421 9 4229 Auxiliary Wired Loops A used can use Zn 10 63 if 4219 4229 IS NOT used Zn 18 63 if 421 9 4229 IS used RPT CODE FOR ONLY INPUT FROM PREVIOUS PAGE RPT CODE Loop F Exp Zone FOR RF ONLY4 INPUT ZONE No ZONE TYPE OF ZONE ASSIGNMENT TABLE HEADINGS Nos are from 01 to 63 92 95 96 99 Some are pre assigned Field 25 set for auxiliary wired loops 421 9 or 4229 use Zone Nos 10 17 for loops A H Field 22 set for RF 5800 use Zone Nos 18 63 if 4219 4229 is ALSO used or 10 63 if 4219 4229 is NOT used Not Used Entry Exit 1 Entry Exit 2 Perimeter Interior Follower Trouble Day Alarm Night 24 Hr Silent 24 Hr Audible 24 Hr Aux Fire Interior w Delav ArrrWtay Arm Away Disarm No Alarm Response Silent Burglary PARTITION No ALARM REPORT CODE Values for zones 01 08 Hex Digits For each Hex Di forE 15 forl If benoreportforthatzone entec for O 9 10 for A 11 for B 12 for C 13 for D contact ID reporting this is enabling code only Enter any hex digit other than 00 in the first pair of The second pair of boxes is ignored Wire Wire 4219 or 4229 for RF Supervised RF 4 for UR Unsupervised RF 5 for BR But

Related Files