Ademco - Vista-2000 (Vista10se) Programming Guide
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-vista-2000-vista10se-programming-guide-9802617453.pdf |
---|---|
Type | |
Size | 1.07 MB |
Downloads |
Text Preview
SYSTEM 4 97 OF CONTENTS Form of Programming Programming Information the Programming Mode a Data Field a Data Field Erasing an Entry in a Data Field Menu Mode Programming Q 56 Q 80 Q 81 Q 82 Q 83 Factory Defaults System Setup Fields the Programming Mode Series Transmitter Input Loop Identification Vocabulary List For Entering Zone Descriptors ASCII Chart For Adding Custom Words Response Type Definitions Field Descriptions Programming and Control Downloading Information Required Download Programming Information Programming Advisory Notes of Connections Diagram Back Cover 23 2 PROGRAMMING FORM programming requires the use of a 2 line Alpha keypad e g 6139 connected to the keypad terminals on the control set all program fields to Ademco default values Key Q 97 Values Function SETUP Q 20 Q 27 20 CODE 4 digits 0 9 4 1 1 1 Default Value 21 QUICK ARM ENABLE 22 RF SYSTEM TYPE 23 FORCED BYPASS FUNCTION no 1 yes 24 RF HOUSE ID CODE 0 0 0 none 1 bypass open zones 0 none 1 5700 System 4281 type rcvr 2 5800 System 5881 5882 type rcvr 25 OUTPUT RELAY MODULE 26 VOICE MODULE ACCESS CODE 0 none 3 4204 0 0 27 OUTPUT TO LONG RANGE RADIO 0 SOUNDS AND TIMING Q 28 Q 39 28 SINGLE ALARM SOUNDING ZONE 0 no 1 yes enter 01 31 for 5700 System Enter also for 5827 5827BD Keypad if used in 5800 0 digit Enter 1 2nd digit Enter only 11 for 12 for in either position disabled no 1 yes If yes selected dialer reports to PRIMARY No field Q 47 will also be via LRR All dialer and LRR reports will be in Contact ID format overriding field Q 46 29 FIRE SOUNDER TIMEOUT 30 ALARM BELL TIMEOUT 38 ENTRY DELAY 0 fire sounder timeout 1 no fire sounder timeout 0 none 1 4 min 2 8 min 3 12 min 4 16 min 0 0 sec 1 20 sec 2 30 sec 3 45 sec 4 60 sec 5 90 sec Delay ENTRY Delay 15 sec 39 AUDIBLE EXIT WARNING 0 no 1 yes PROGRAMMING Q 40 Q 50 Note In fields Q 40 Q 41 Q 42 Enter 0 11 for Q 12 for 13 for a pause 40 PABX ACCESS CODE 0 0 0 0 0 1 2 1 41 PRIMARY PHONE No 42 SECONDARY PHONE No 43 SUBSCRIBER ACCT No up to 4 digits if PABX code is needed to access an outside line If fewer than 4 digits do not fill unused spaces by pressing Q and press 41 if entering next field clear entries from field press Q 40 Q up to 12 digits If fewer than 12 digits entered exit by pressing Q and press Q 42 entering next field To clear entries from field press Q 41 Q up to 12 digits If fewer than 12 digits entered exit by pressing Q and press 43 if next field To clear entries from field press Q 42 Q 0 9 11 for B 12 for C 13 for D 14 for E 15 for F Enter Q as the digit if a 3 digit account number for 3 1 dialer reporting format is used Enter 0 as first digit of a 4 digit account number for Nos 0000 End field by pressing Q press next field For Acct No 1234 enter Acct No B234 enter Acct No 123 enter 45 PHONE SYSTEM SELECT 0 Cent Station IS NOT on a WATS line 0 Pulse Dial 1 Tone Dial If Cent Station IS on a WATS line 2 Pulse Dial 3 Tone Dial Entry of a number other than one specified will give unpredictable results 3 46 FORMAT 0 47 REPORTING A 10 digit code is sent to the pager consisting of a 4 digit Subscriber a 3 digit Event code a 3 digit User or Zone See VISTA 10SE Installation Instructions for an explanation of the 10 digit code see field Q 27 3 1 4 1 ADEMCO L S STANDARD 3 1 4 1 RADIONICS STANDARD 4 2 ADEMCO L S STANDARD 4 2 RADIONICS STANDARD or undefined 4 2 ADEMCO EXPRESS ADEMCO CONTACT ID REPORTING 3 1 4 1 ADEMCO L S EXPANDED 3 1 4 1 RADIONICS EXPANDED 0 0 Disable Backup report only PRIMARY PHONE No Alarms Restore Cancel All Reports except Open Close Test Alarms Restore Cancel All Reports except Open Close Test All Reports PRIMARY PHONE No All reports except Open Close All reports All reports All reports except Open Close Reporting SECONDARY PHONE No Reports Test Reports Reports Reports PAGING No SECONDARY Alarms Open Close Troubles Alarms Troubles Alarms Open Close Troubles Alarms Open Close for Users 5 Can only be used if Primary reporting is Ademco Contact ID See field Q 47 in the DATA FIELD DESCRIPTIONS section 48 SEC DIALER DELAY BURG 49 TEST MESSAGE 50 SELECT 0 no 1 yes 0 0 0 OF ARMING DING 3 RESPONSE TO OPEN 0 0 none 1 24 hrs 2 wkly 3 monthly Enter Test Code in field Q 64 0 Radionics 0 9 B F reporting 1 SESCOA 0 9 only reporting 0 for all other formats 0 0 no 1 yes 2 yes but with RF arming only 0 400 ms nominal 1 10 ms nominal of a number other than one specified will give unpredictable results 51 52 56 ASSIGNMENT ALARM REPORT CODES See explanation on next page RPT CODE INPUT Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Duress Panic Q or B Panic 1 Q or A Panic 3 or C RF Expansion Zone