Ademco - Vista 20P v2 Programming Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | ademco-vista-20p-v2-programming-manual-0461985327.pdf |
---|---|
Type | |
Size | 1.30 MB |
Downloads |
Text Preview
cid 1 cid 2 cid 3 cid 4 cid 5 cid 6 cid 7 cid 8 cid 9 cid 10 cid 9 cid 3 cid 11 cid 3 cid 12 cid 13 cid 14 cid 12 cid 15 OFF MAX TEST STAY OFF MAX TEST STAY 4 02 ENTER PROGRAMMING MODE programming requires the use of an alpha keypad connected to the keypad terminals on the control POWER UP then depress and both at once within 50 seconds of powering up if was used to exit program this method must be used to reenter program mode Initially key Installer Code 4 1 1 2 plus 8 0 0 FIELD PROGRAMMING PROCEDURES to a Data Field Data Field Number followed by the required entry the desired field number appears simply make the required entry When the last entry for a is entered the keypad beeps three times and automatically displays the next data field in the number of digits that you need to enter in a data field is less than the maximum digits available example the phone number fields 41 42 enter the desired data then press to end the The next data field number is displayed a Data Field Press Field Number an Entry will be displayed for that field number No changes will be accepted in this mode Field Number Applies only to fields 94 and pager programming fields MODE PROGRAMMING Interactive Mode No for example The alpha display keypad will display the first of a series of prompts entries Mode Zone Programming to Program characteristics report codes alpha descriptors and serial numbers for 5800 RF Function Key Programming Unlabeled keypad keys known as ABCD keys for special functions Zone Programming mode Output Device Mapping Output Programming Zone List Programming Alpha Programming options as 56 mode but with fewer prompts Intended for those familiar with type of programming otherwise 56 mode is recommended module addresses and map individual relays powerline carrier devices or 4204 Relay modules Powerline Carrier devices or on board triggers Lists for relay powerline carrier activation chime zones pager zones etc alpha descriptors DOWNLOAD and RESET DEFAULTS Initializes download ID and subscriber account number Sets all data fields to original factory default values EXIT PROGRAMMING MODE Exits programming mode and prevents re entry by Installer Code 8 0 0 If is used to exit programming system must be powered down and method A above used to enter the programming mode field 88 for other 98 Program mode lockout options Exits programming mode and allows re entry by Installer Code 8 0 0 or method 1 above Messages OPEN CIRCUIT no communication between Keypad and Control or ENTRY ERROR ERROR invalid field number entered re enter valid field number powering up AC dI disabled or Busy Standby and NOT READY will be displayed after approximately 4 seconds will revert to a message in approximately 1 minute which allows PIRS etc to stabilize You can bypass this by pressing 0 E4 or E8 appears more zones than the expansion units can handle have been programmed Correct the programming then completely de power and re power the control to clear this indication and remove the disable indication 2 values apply to all controls except field 189 which applies to the VISTA 20PS only of a number other than one specified will give unpredictable results Values shown in brackets are factory defaults shown in dashed boxes indicate partition entries for VISTA 20P only not applicable for VISTA 15P Function Data Entries Programmable Values SETUP 20 INSTALLER CODE digits 0 4112 QUICK ARM ENABLE no 1 yes RF JAM OPTION QUICK FORCED BYPASS 24 RF HOUSE ID CODE CHIME BY ZONE POWERLINE CARRIER DEVICE X CODE ACCESS CODE FOR MODULE 29 LONG RANGE RADIO OUTPUT SOUNDS AND TIMING SINGLE ALARM SOUNDING per ZONE FIRE ALARM SOUNDER TIMEOUT ALARM SOUNDER BELL TIMEOUT EXIT DELAY ENTRY DELAY 1 zone type 01 ENTRY DELAY 2 zone type 02 EXIT WARNING CONFIRMATION OF ARMING DING POWER UP IN PREVIOUS STATE 1 Part 2 Common 0,0 1 Part 2 0 0,0 1 Part 2 00 1 only 0 0 0 0 1 60,60 1 Part 2 30,30 1 Part 2 zones use same as partition 1 30,30 1 Part 2 1 0,0 1 Part 2 1 no RF Jam detection 1 send RF Jam report UL must be 1 if wireless devices are used no quick bypass UL must be allow quick bypass code 6 disable all wireless keypad usage using 5827 5827BD or 5804BD keypad no 1 yes select zones to chime on zone list 3 81 Menu mode A 1 B 2 C 3 D 4 E 5 F 6 G H 8 I 9 J 10 K 11 L 12 M 13 N 14 O 15 P UL not for fire or UL installations disable 1st digit enter 1 2nd digit enter 11 or 12 for UL must be for UL Commercial Burg installations disable 1 enable no UL must be 1 yes sounder stops at timeout no sounder timeout UL must be for fire install none 1 4 min 2 8 min 3 12 min 4 16 min For residential fire alarm installation must be set for a of 4 min option 1 for UL Commercial Burglary must be minimum 16 min option 4 96 0 96 secs 97 120 secs Installations minimum exit delay is 45 seconds see inst instr for requirements zones use same delay as partition 1 96 0 96 seconds 120 seconds 180 seconds 240 seconds UL Residential Burglary Alarm installations must be set a maximum of 30 seconds entry delay plus dial delay not exceed 1 min For UL Commercial Burglar Alarm entry delay may not exceed 45 seconds 35 Entry Delay 1 above for entries Installations entry delay is seconds no 1 yes Installations must be enabled enter 1 no 1 yes wired keypads and RF yes RF only must be for UL Commercial Burglar Alarm inst no 1 yes UL must be PROGRAMMING not fill unused spaces Enter 0 11 for 12 for 13 for a 2 second pause If fewer than the maximum digits entered exit the by pressing The next data field number is displayed 40 PABX ACCESS CODE Enter up to 6 digits To clear entries press If call waiting enter 11 70 plus 13 pause 41 PRIMARY PHONE No 42 SECOND PHONE No up to 20 digits To clear entries press or respectively 3