ADT-BG-12LX Pull Station

File Preview
File Preview
Click below to download for free

File Data

Name adt-bg-12lx-pull-station-0231647895.pdf
Type PDF
Size 687.89 KB
Downloads

Text Preview

ADT BG 12LX Manual Pull Station ADT BG 12LX is a state of the art dual action i e two motions to activate the station pull station that an addressable interface for Unimode 9050UD Uni 200UDLS and Unimode 9600 Series intelligent control FACPs Because the ADT BG 12LX is addressable control panel can display the exact location of the activated station This leads fire personnel quickly to the location the alarm Maintenance personnel can open station for inspection and setting without causing an alarm condition Built in bicolor LED which is visible through the handle of station flashes in normal operation and latches steady when in alarm Handle latches in down position and the word to clearly indicate the station has been operated Captive screw terminals wire ready for easy connection to loop accepts up to 12 AWG 3.25 mm wire Can be surface mounted with SB 10 or SB I O or semi mounted Semi flush mount to a standard single double gang or 4 10.16 cm square electrical box Smooth dual action design Meets ADAAG controls and operating mechanisms guide Section 4.1.3 13 meets ADA requirement for 5 lb activation force Highly visible Attractive shape and textured finish Key reset Optional trim ring BG12TR Meets UL 38 Standard for Manually Actuated Signaling Braille text on station handle door and handle are molded of durable polycarbonate with a textured finish Shipping Weight 9.6 oz 272.15 g Normal operating voltage 24 VDC Maximum SLC loop voltage 28.0 VDC Maximum SLC standby current 375 Maximum SLC alarm current 5 mA Temperature Range 32 to 120 0 to 49 Relative Humidity 10 to 93 noncondensing For use indoors in a dry location ADT BG 12LX will mount semi flush into a single gang or standard 4 10.16 cm square electrical outlet or will surface mount to the model SB 10 or SB I O sur backbox If the ADT BG 12LX is being semi flush E 450 Devices ADT BG 12LX Manual Pull Station then the optional trim ring BG12TR may be used BG12TR is usually needed for semi flush mounting with 4 cm or double gang boxes not with single gang boxes in then pulling down on the handle causes it to latch the down activated position Once latched the word in bright yellow appears at the top of the handle a portion of the handle protrudes from the bottom of the To reset the station simply unlock the station with the and pull the door open This action resets the handle clos the door automatically resets the switch manual station on command from the control panel data to the panel representing the state of the manual Two rotary decimal switches allow address settings 159 with Breakaway Tab removed for Unimode 9600 1 99 and Unimode 200UDLS 1 50 for Unimode Fire Alarm Stations shall be non coded with a key reset lock in order that they may be tested and so that after actual Emergency Operation they cannot restored to normal except by use of a key An operated sta shall automatically condition itself so as to be visually as activated Manual stations shall be constructed of polycarbonate material with clearly visible operat instructions provided on the cover The word FIRE shall on the front of the stations in white letters 1.00 inches cm or larger Stations shall be suitable for surface on matching backbox SB 10 or SB I O or semi flush 4 13 2012 Page 1 of 2 on a standard single gang double gang or 10.16 cm square electrical box and shall be installed the limits defined by the Americans with Disabilities Act or per national local requirements Manual Stations be Underwriters Laboratories listed stations shall connect with two wires to one of the con panel SLC loops The manual station shall on command the control panel send data to the panel representing the of the manual switch Manual stations shall provide setting by use of rotary decimal switches Line Information Dual action addressable pull station Includes locking feature Surface backbox metal Surface backbox plastic Optional trim ring Keys set of two Listings and Approvals some cases certain modules or applications may not be by certain approval agencies or listing may be in pro Consult factory for latest listing status UL Listed S285 MEA 67 02 E CSFM 7150 1574 0178 FM Approved U S Patent No D428,351 6,380,846 6,314,772 All rights reserved Unauthorized use of this document is strictly document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact ADT Phone 561 988 3600 FAX 561 988 3675 in the U S A 2 of 2 DA 46781 D 4 13 2012

Related Files