Continuum Expansion I/O Family Tour Andover Controls xP Expansion I/O Family provides a and cost-effective means to add additional inputs, outputs, or a display to the Infinet II and BACnet family of distributed controllers. to two modules plus a local display can be powered directly from of the following controllers in the Infinet II (i2) or BACnet (b3) i2/b3 920, i2/b3 810, i2/b3 814, i2/b3 850, i2/b3 851, or 853. The bCX1 Controller/Router models can also be used to xP Expansion modules (and Display) and are the only that support the xPBA4 and xPBD4 module types. No power supply is required to power the Module(s). Consult xP Modules and Local Display Modules User Guide for valid xPDI8 The xPDI8 module allows the addition of 8 Digital Inputs a small enclosure. xPUI4 The xPUI4 module allows the addition of 4 Universal Each can be configured independently based on your needs Digital, Temperature, Motion Sensor, or Pulse Counter Inputs, providing built-in flexibility for your different application xPAO2/xPAO4 Both the xPAO2 (2 Analog Outputs) and the (4 Analog Outputs) allow the addition of Analog Outputs. output has individual manual override switches to select On, or Auto for program control. When in override mode, each also has a potentiometer to allow control of the override point. xPDO2/xPDO4 Both the xPDO2 (2 Digital Outputs) and the (4 Digital Outputs) allow the addition of Digital Outputs. output has individual manual override switches to select On, or Auto for program control. xPBA4/xPBD4 Both the xPBA4 and the xPBD4 combine the of two xP Expansion modules. Similar to the xPUI4, both the addition of 4 Universal Inputs. The xPBA4 allows the of 4 Analog Outputs (like the xPAO4), and the xPBD4 for the addition of 4 Digital Outputs (like the xPDO4). (Note: xPBA4 and xPBD4 Expansion Modules can only be connected the bCX1 Controller/Routers.) DISPLAY local display with keypad (xP Display) allows for the addition of a programmable local display module that can be mounted within feet (3 meters) of the controller. Connected via a ribbon cable, the Display easily allows the Operator Interface to be mounted on the of an enclosure or on a wall below or next to the controller. Powerful, Flexible System for Simple Addition of a I/O Points Individual Overrides of all Outputs Universal Inputs Provide the Flexibility, including a High Speed Counter Input Individual Overrides and for all Analog Full Function Manual Overrides Status Feedback 4-Line, 16-character Display Keypad Provides Simple Convenient Operator Locally Mounted or Remote of Modules and Display Module Power Supplied by the Reducing Installation and Cost to xPAO4; only the first outputs are populated. to xPDO4; only the first outputs are populated. Environment: Type: I/O Modules to two I/O module and an xP- may be connected to a All controllers provide a total 180 mA of power for the modules. module power consumption is below. Reference installation sheet valid combinations. (DIGITAL INPUTS) Consumption: mA Digital Inputs Impedance: ohm ref to +5VDC VDC, or contact closure 50% duty cycling, 3.57 ms pulse min. Protection: VAC/DC +/- 1500 V transients (0 10 RH (non- 3.21″H x 7.10 x 1.60″D x 180 W x 41 D) mm 7.25″H x 5.00 x 1.65″D x 127 W x 42 D) mm 0.48 lb (0.22 kg) 1lb (0.45 kg) Open class, IP 10. Flammability of UL94-5V (UNIVERSAL INPUTS) Consumption: Universal Inputs mA (xPUI4) mA (xPBA4) mA (xPBD4) VDC
Continuum Expansion I/O Family Tour Andover Controls xP Expansion I/O Family provides a and cost-effective means to add additional inputs, outputs, or a display to the Infinet II and BACnet family of distributed controllers. to two modules plus a local display can be powered directly from of the following controllers in the Infinet II (i2) or BACnet (b3) i2/b3 920, i2/b3 810, i2/b3 814, i2/b3 850, i2/b3 851, or 853. The bCX1 Controller/Router models can also be used to xP Expansion modules (and Display) and are the only that support the xPBA4 and xPBD4 module types. No power supply is required to power the Module(s). Consult xP Modules and Local Display Modules User Guide for valid xPDI8 The xPDI8 module allows the addition of 8 Digital Inputs a small enclosure. xPUI4 The xPUI4 module allows the addition of 4 Universal Each can be configured independently based on your needs Digital, Temperature, Motion Sensor, or Pulse Counter Inputs, providing built-in flexibility for your different application xPAO2/xPAO4 Both the xPAO2 (2 Analog Outputs) and the (4 Analog Outputs) allow the addition of Analog Outputs. output has individual manual override switches to select On, or Auto for program control. When in override mode, each also has a potentiometer to allow control of the override point. xPDO2/xPDO4 Both the xPDO2 (2 Digital Outputs) and the (4 Digital Outputs) allow the addition of Digital Outputs. output has individual manual override switches to select On, or Auto for program control. xPBA4/xPBD4 Both the xPBA4 and the xPBD4 combine the of two xP Expansion modules. Similar to the xPUI4, both the addition of 4 Universal Inputs. The xPBA4 allows the of 4 Analog Outputs (like the xPAO4), and the xPBD4 for the addition of 4 Digital Outputs (like the xPDO4). (Note: xPBA4 and xPBD4 Expansion Modules can only be connected the bCX1 Controller/Routers.) DISPLAY local display with keypad (xP Display) allows for the addition of a programmable local display module that can be mounted within feet (3 meters) of the controller. Connected via a ribbon cable, the Display easily allows the Operator Interface to be mounted on the of an enclosure or on a wall below or next to the controller. Powerful, Flexible System for Simple Addition of a I/O Points Individual Overrides of all Outputs Universal Inputs Provide the Flexibility, including a High Speed Counter Input Individual Overrides and for all Analog Full Function Manual Overrides Status Feedback 4-Line, 16-character Display Keypad Provides Simple Convenient Operator Locally Mounted or Remote of Modules and Display Module Power Supplied by the Reducing Installation and Cost to xPAO4; only the first outputs are populated. to xPDO4; only the first outputs are populated. Environment: Type: I/O Modules to two I/O module and an xP- may be connected to a All controllers provide a total 180 mA of power for the modules. module power consumption is below. Reference installation sheet valid combinations. (DIGITAL INPUTS) Consumption: mA Digital Inputs Impedance: ohm ref to +5VDC VDC, or contact closure 50% duty cycling, 3.57 ms pulse min. Protection: VAC/DC +/- 1500 V transients (0 10 RH (non- 3.21″H x 7.10 x 1.60″D x 180 W x 41 D) mm 7.25″H x 5.00 x 1.65″D x 127 W x 42 D) mm 0.48 lb (0.22 kg) 1lb (0.45 kg) Open class, IP 10. Flammability of UL94-5V (UNIVERSAL INPUTS) Consumption: Universal Inputs mA (xPUI4) mA (xPBA4) mA (xPBD4) VDC