Andover Controls Continuum PS 120-240 AC 50-U Power Supply
File Preview
Click below to download for free
Click below to download for free
File Data
Name | andover-controls-continuum-ps-120-240-ac-50-u-power-supply-0618592347.pdf |
---|---|
Type | |
Size | 972.02 KB |
Downloads |
Text Preview
Power Supply Module Provides VDC Power and Battery UPS Power to Continuum CPU and I O Built in Battery Charger Selection of Programmable Backup Modes via English Programming Non UPS Model Available for Use an Extended Power Source 48VDC Model Available for Use DIN Rail Mounting and Slide Connectors for Easy 120 240 AC 50 U Power Supply Continuum PS 120 240 AC 50 U power supply module is designed to provide 24VDC for the Continuum NetController CPU module and its associated Continuum I O In addition the PS 120 240 AC 50 U model provides full UPS battery backup in the of an AC line failure PS 120 240 AC 50 U power supply is part of the Andover Controls Continuum Ethernet intelligent building system The Continuum system allows you to cost effectively mix match DIN rail mounted CPU power supply and various combinations of I O modules user interfaces to meet your control and monitoring needs PS 120 240 AC 50 U offers an impressive array of features that reduce or eliminate the of power failure A built in battery charger in the PS 120 240 AC 50 U provides 15 maximum to the battery The charger is current limited to prevent overloading the supply in the event of a shorted or defective battery Using standard rechargeable lead batteries the PS 120 240 AC 50 U will provide full UPS operation including all I O for up to 60 minutes at 35 watts power consumption full operation of the CPU only including modem and network interface with no I O power for four hours and of DRAM and real time clock for 72 hours duration These backup modes can be and controlled through Andover Controls Plain English programming Maximum time of the battery charger is 48 hours using recommended batteries Two 12V AHr sealed rechargeable batteries are included with the UPS model Extended times are available using larger batteries UPS circuit provides the Continuum CPU with two status signals indicating the operating of the power supply signal indicates an AC power failure and a change over UPS mode and the other signal indicates when the battery voltage has reached an unsafe level and will soon shutdown A disconnect switch removes the battery and further discharge of the battery connector located on the bottom of the power supply is provided for an optional AC power LED This option is ideal if you mount your Continuum system within a larger control or enclosure and wish to verify power to the system from a separate location PS 120 240 AC 50 U features a sleek lightweight casing designed for natural convection Built in quick release fasteners at the back of the power supply module are provided DIN rail mounting tools required These fasteners also snap into a locked position for mounting The power supply is designed for mounting in an optional NEMA 1 sytle enclosure Manuals Online 120 240 AC 50 120 240 AC 50 120 240 AC 50 120 240 AC 50 120 240 AC 50 non UPS version the PS 120 240 AC 50 is also available This power supply can also be used as an extended source to power additional I O modules directly extending the capabilities of a typical Continuum system to remote locations Because there is no built in battery charger in this model a full 50 watts of power is DC 50 DC 50 DC 50 DC 50 DC 50 PS DC 50 model is available This model accepts power from to VDC and allows industries such as to provide uninterrupted power to critical environmental monitoring and control equipment their own battery backed power systems I M E N S I O N D R A W I N G Manuals Online P E C I F I C A T I O N S Voltages to 240 VAC 50 60 Hz to 53 VDC PS DC 50 model only Voltages VDC all models Power Available watts PS 120 240 AC 50 U model watts PS 120 240 AC 50 and PS DC 50 models Protection circuit protection protection protection on inputs protection on AC inputs Environment to 120 0 to 49 10 to 95 RH non condensing x 6.7 x 2.5 228.7 x 170.2 x 63.5mm lbs 0.79kg on DIN rail or wall mount using attached fasteners Continuum NEMA 1 style available 120 240 AC 50 U model only Backup Backup Duration backup UPS circuit with built in battery charger provides automatic battery UPS power in event of AC line failure Two 12V 7.0 AHr sealed rechargeable connected with 5 amp pico fuse provide a 24 VDC battery source minutes 35 watts power consumption full UPS to CPU plus I O power 4 hours module only including modem and network interface with no I O and 72 hours and real time clock Expandable by use of greater amp hour batteries For for a 4 hour full backup time minimum of 2 12V 28 AHr batteries must be Charging Time hours maximum for built in 15 watt battery charger to fully charge battery from system battery discharge point Input Input 24VDC 120 240 AC 50 U and PS 120 240 AC 50 models only screw connector DC 50 model only screw connector 120 240 AC 50 U model only screw connector Power Indicator connector for optional power indicator 12V LED lamp optional cable available 24VDC Signal plug in connector on right side of power supply module provides power to Continuum NetController CPU module and associated I O modules Manuals Online or DC Power ON OFF Status Indicator 120 240 AC 50 U model only Power ON OFF Status Indicator AC or DC power ON and OFF Located on top left side of module Indicated by POWER LED LEDS SWITCHES LEDS SWITCHES LEDS SWITCHES LEDS SWITCHES LEDS SWITCHES INDICATOR LEDS POWER POWER LISTINGS LISTINGS LISTINGS LISTINGS LISTINGS 916 FCC CE Power Indicator LED Cable Assembly 2 ft in length Order cable number 01 0100 422 Controls Corporation World Headquarters Brickstone Square Andover Massachusetts 01810 USA 978 470 0555 Fax 978 470 0946 Controls Ltd Road Ashby de la Zouch Leicestershire LE65 2UG England 01530 417733 Fax 01530 415436 Control GmbH Seerhein 8 D 78467 Konstanz Germany 07531 99370 Fax 07531 993710 Control S A Avenue de Fontainebleau 94270 Le Kremlin Bicetre France 49 60 63 63 Fax 49 60 62 71 Controls Corporation Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong 2739 5497 Fax 2739 7350 1998 Andover Controls Corporation Data subject to change without notice brand names trademarks and registered trademarks are the property of their respective holders Andover Product Installation Guides for exact installation instructions and specifications Patent 4591967 120 240 AC 50 U A Manuals Online