Andover Controls emx150

File Preview
File Preview
Click below to download for free

File Data

Name andover-controls-emx150-4837205196.pdf
Type PDF
Size 604.37 KB
Downloads

Text Preview

Infinity 150 EMX 151 EMX 155 EMX 156 EMX 160 150 EMX 151 EMX 155 EMX 156 EMX 160 150 EMX 151 EMX 155 EMX 156 EMX 160 Expansion Modules 150 EMX 151 EMX 155 EMX 156 EMX 160 150 EMX 151 EMX 155 EMX 156 EMX 160 Andover Controls Infinity family of expansion modules provides a convenient and cost effective E A T U R E S E A T U R E S E A T U R E S E A T U R E S E A T U R E S to add input and output points to Andover Infinet distributed application controllers Cost Effective I O Expansion Meet Additional Point Needs Additional Points Provide Controller Modular Design for Easy Installation to two modules can be powered directly from any of these Infinet controllers the SCX 920 LCX TCX 850 TCX IDX 851 TCX 853 TCX 855 and the ACX 700 Additional modules can be by providing power from an external 24 VDC supply Consult the Infinity Expansion Module Guide for more specific information on the use of expansion modules 150 EMX 150 contains two analog outputs configurable for either 0 20 VDC or 0 20 mA operation Each output contains override switch and potentiometer for local control 151 EMX 151 contains 2 high resolution 12 bit analog outputs configurable for either 0 10 VDC or 0 20 mA operation No switches are provided 155 EMX 155 provides two Form C relay outputs rated for 24 VAC VDC operation Each relay can be used for on off control motors and lighting or can be used for pulse width modulation control with 0.1 second resolution Each output contains override switch for manual operation with software feedback of the switch position 156 EMX 156 provides 2 digital outputs rated for 120 240 VAC operation Each output is a field replaceable solid state that can be used for control of motors and lighting or can be used for pulse width modulation control with 0.1 second Each output has 4000 V RMS isolation and has a maximum surge current of 80 amps Each output contains an switch for manual operation with software feedback of the switch position 150 EMX 151 EMX 155 EMX 156 EMX 160 150 EMX 151 EMX 155 EMX 156 EMX 160 150 EMX 151 EMX 155 EMX 156 EMX 160 Expansion Modules 150 EMX 151 EMX 155 EMX 156 EMX 160 EMX 150 EMX 151 EMX 155 EMX 156 EMX 160 160 EMX 160 contains 8 digital inputs designed for dry contact signals In addition each input can be configured to pulses up to 140 per second module points are treated in the same manner as the built in I O of each Infinet controller Once expansion are assigned using Andover Controls Plain English programming language they are automatically added to input and output summaries and can be used unrestricted in programs reports and alarms modules are designed to be plugged into the expansion port found at the bottom of each Infinet controller expansion module enclosure is intended for panel mounting using two sheet metal screws TO PREVIOUS OR CONTROLLER POTS 1.52 39mm FOR EMX Size differs for all EMX Modules 150 Dimensional Diagram P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S to two modules can be powered directly from the Infinet controller Only 1 151 Additional modules can be powered with an external 24 VDC power Environment to 120 0 to 49 10 to 95 RH non condensing Type open class sheet metal IP 10 Interface expansion serial port of the local Infinet controller Power Connector connector Connectors two piece terminal blocks EMX 156 has screw terminals Modules Infinet Controller Consult the Infinity Expansion Module Configuration Guide for the maximum of inputs outputs allowed on each particular Infinet controller LISTINGS 916 FCC CE 150 151 plus potentiometer no software feedback Consumption mA x 4.88 H x 1.52 D 155W x 124H x 39D mm analog outputs mA or 0 20 VDC for each output mA into maximum 750 ohms VDC into minimum 4,000 ohms mA or 0.1 VDC high resolution analog outputs mA or 0 10 VDC P E C I F I C A T I O N S Cont P E C I F I C A T I O N S Cont P E C I F I C A T I O N S Cont P E C I F I C A T I O N S Cont P E C I F I C A T I O N S Cont 151 Continued mA into maximum 1,000 ohms 0 10 VDC into minimum 4,000 ohms Consumption x 4.88 H x 1.52 D 155W x 124H x 39D mm or 2.44 mV 0.1 of span digital outputs C relay 24 VAC VDC second 155 Rating 156 Rating Load switch with software feedback Consumption mA x 4.42 H x 1.82 D 155W x 112H x 46D mm high voltage digital outputs A solid state device field replaceable 120 240 VAC 25 2A 120 240 VAC 50 DC loads not permitted VAC 20 mA Cycle Surge Current Isolation V RMS Power Factor 156 provides switching for inductive loads with 0 4 to 1.0 power factor second switch with software feedback Consumption mA x 4.42 H x 1.52 D 155W x 112H x 39D mm 160 digital inputs Any or all points can be assigned counter inputs All inputs must be dry contacts Counter Frequency Hz 50 duty cycling 3.57 ms minimum pulse width Voltage VDC into 24k ohms Protection VAC VDC indefinitely on any single channel Consumption mA volt transients x 5.72 H x 1.52 D 155W x 145H x 39D mm Controls Corporation Headquarters Brickstone Square Massachusetts 01810 USA 978 470 0555 cid 127 Fax 978 470 0946 Controls Ltd Road LE65 2UG England 01530 417733 cid 127 Fax 01530 415436 Controls GmbH Seerhein 8 Konstanz Germany 07531 99370 cid 127 Fax 07531 993710 Controls S A Dolomites 2 Rue Roger Salengro Fontenay Sous Cedex France 331 53 99 16 16 cid 127 Fax 331 53 99 16 15 Controls Asia 1201 02 Phase I Cheuk Nang Centre Hillwood Road Tsim Sha Tsui Hong Kong 852 2739 5497 cid 127 Fax 852 2739 7350 Controls Mexico Sur 1722 501 Florida D F 01030 Mexico 525 661 56 72 cid 127 Fax 525 661 54 15 Patent 4591967 Andover Controls Corporation subject to change without notice Andover Product Installation Guides exact installation instructions and

Related Files