Andover Controls i2 800 Controller

File Preview
File Preview
Click below to download for free

File Data

Name andover-controls-i2-800-controller-2067189543.pdf
Type PDF
Size 816.90 KB
Downloads

Text Preview

Powerful Flexible Local for the Most Applications Non Volatile Flash Memory Utmost Reliability Both Application and Operating Local Extended Storage of Data View and Modify Information Optional Smart Sensor Local On Board Service Port N F I N E T I I 800 Series Local Controllers i2800 series are designed for control of small Air Handling Units Unit Top and other mechanical plant equipment Choose the i2800 series with the configuration that matches your application The i2800 designed for stand alone equipment control of Roof or Air Handling Units features eight Universal Inputs one Sensor Room Sensor input plus eight program Digital Outputs The i2804 designed for stand alone equipment control of Roof or Air Handling Units features eight Universal Inputs one Sensor Room Sensor input plus four program controlled Outputs and four Analog Outputs for direct control of requiring 0 10 volt control signals The i2804 is compatible with Continuum only models feature an additional room sensor input which supports Smart Sensor or any standard room temperature sensor i2800 series also features Flash memory increased user memory a fast 32 bit processor for faster scan times with plenty of memory for data logging of your critical data i2800 communicates with the entire Andover Controls Infinet field bus i e both Infinet and Infinet II controllers and is with both the Continuum CyberStation and Infinity SX 8000 Up to 254 Infinet devices can be networked to any Andover controller RELIABILITY WITH FLASH MEMORY i2800 non volatile Flash memory stores your operating system and programs so that in the event of a power loss your will be restored when power is returned In addition the Flash allows for easy upgrades of your operating system via software eliminating the need to swap out proms The i2800 controllers an on board battery to safeguard your runtime data protecting point data and log data from being lost if power is removed BUILDING SMART input configuration on the i2800 series consists eight full range 10 bit Universal inputs that accept 0 5VDC digital on off counter signals up 4Hz temperature signals or supervised alarm for security applications or broken wire The i2800 series offers an additional input support the Andover Smart Sensor or any room temperature sensor i2800 contains eight Form C relay outputs each for 24 VAC VDC 3 amp while the i2804 four Form C relay outputs and four analog 0 10V 4 20mA CAPABILITIES dynamic memory of the i2800 can be allocated any combination of programs scheduling and data logging using the powerful Controls Plain English programming Our object oriented Plain English with intuitive keywords provides an easy to tailor the controller to meet your exact Programs are entered into the i2800 the Continuum CyberStation Programs are stored and executed by the i2800 controllers multiple i2800 series controllers is easy with Plain English A complete copy one i2800 programs can be loaded directly into i2800s without changing any point names or SENSOR INTERFACE i2800 provides a built in connection for Smart Sensor The Smart Sensor provides 2 character LED display and a 6 button keypad that enables operators and to change setpoints balance VAV boxes occupancy status and turn equipment on off An enhanced version of the Smart Sensor is available with a 4 digit custom LCD that the following icons PM Setpoint Heat CFM Fan OA and SP Drawing Drawing Drawing Sensor Drawing Drawings P E C I F I C AT I O N S Series Local Controllers 12 24VDC auto sensing 10 50 60 Hz Consumption VA Protection with 3 amp fuse MOV protected Real Time Clock Synchronized through Infinet by network Environment Type Backup 0 10 RH non x 6.01 x 2.14 D 229 H x W x 54 D mm lbs 0.61 kg Open class IP 10 Flammability rating of mount non rechargeable lithium Provides 5 years typical power failure backup of RAM Interface Through Infinet RS 485 field bus to Speed Length Media Error Checking controller to 19.2K baud ft 1,220m standard for Infinet I2 module allows extension to longer and is required after every group 32 units on the network twisted shielded pair low cable Standard CRC 16 Cyberstation and Infinity SX systems The i2804 is compatible with Continuum only Universal inputs Voltage 0 5.115 VDC 30 to 230 34 to Digital on off Counter up to 4Hz 50 duty cycle 125 ms min pulse Supervised Alarm single or double Current input 0 20 mA using 250 ohm resistor Smart Sensor Temperature Input 32 to 0 to 41 volts DC ohm to 5.120V or 5M ohm with pull resistor disabled Voltage Range Impedance Resolution Accuracy mV from 23 to 66 or from 10 to 150 CONTINUED Outputs single pole single throw SPST Form C 4 Form C on i2804 two consecutive Form C outputs can be as one Form K Tri state 3A 24VAC VDC Tested according to sec for pulse width modulation analog outputs i2804 only VDC for 0 10V fixed screw terminal connector fixed screw terminal connector 2 12 position fixed screw terminal 1 12 position fixed screw terminal and 1 8 position fixed screw connector fixed screw terminal connector removable screw terminal shrouded connector Active Data Data Status per output Digitals only Rating Accuracy Outputs Rating Resolution Sensor Port LEDS SWITCHES Indicator LEDS Pull up Resistor Switch per input SRAM 1MB FLASH 32 bit Coldfire i2804 REQUIRES Continuum V1.5 version or later of LISTINGS 916 FCC CFR 47 Part 15 ICES 003 AS NZS 3548 Class A CE Smoke Control System Equipment UUKL i2800 S i2804 S Controls Corp Headquarters Brickstone Square Massachusetts 01810 USA 1 978 470 0555 Fax 1 978 470 0946 Controls Europe Road LE65 2UG England 44 1530 417733 44 1530 415436 Controls Germany Seerhein 8 Konstanz 49 7531 99370 49 7531 993710 Controls France Dolomites 2 Rue Roger Salengro Fontenay Sous Bois 33 1 53 99 16 16 33 1 53 99 16 15 Controls Poland 56 Krakow 48 126385500 48 126385501 Controls Asia 1201 02 Phase 1 Cheuk Nang Centre Hillwood Road Sha Tsui East Hong Kong 852 2739 5497 852 2739 7350 Controls Mexico Sur 1722 501 Florida D F 01030 Mexico 5255 5661 5672 5255 5661 5415 Balfour Beatty Company BUILDING SMART Andover Controls Corporation cid 127 All brand names trademarks and registered trademarks are the property of their respective holders DS I I2800 C

Related Files