Andover Controls i2 867 Controller

File Preview
File Preview
Click below to download for free

File Data

Name andover-controls-i2-867-controller-0254973681.pdf
Type PDF
Size 785.03 KB
Downloads

Text Preview

I N F I N E T I I 867 Terminal Controller Infinet II i2 867 is a compact terminal controller that provides low DDC control of package units heat pumps unit ventilators and terminal unit applications Its versatile mix of I O Universal Triac outputs plus an interface to Andover Controls Smart Sensor temperature sensor with programmable keypad allows for control solutions The i2867 also features two analog outputs to reheat valves dampers lighting ballasts etc And because the is enclosed in a sleek modular casing it can be mounted in a area perfect for retrofit applications to all i2 controllers the i2867 features Flash memory increased memory and a fast 32 bit processor for faster scan times with of additional memory available for data logging of your critical i2867 communicates with the entire Andover Controls Infinet field bus i e both Infinet and Infinet II controllers and is with both the Continuum CyberStation and Infinity SX 8000 Up to 254 Infinet devices can be networked to any Andover controller RELIABILITY WITH FLASH MEMORY i2867 non volatile Flash memory stores your operating system and programs so that in the event of a power loss your will be restored when power is returned In additon the Flash allows for easy upgrades of your operating system via software eliminating the need to swap out proms The i2867 includes on board battery to safeguard your runtime data protecting all point and log data from being lost if power is removed input configuration on the i2867 consists of four full range Universal that accept voltage 0 5VDC digital on off counter signals up to or temperature signals The i2867 also offers a fifth input to support Andover Smart Sensor or any standard room temperature sensor BUILDING SMART Compact Terminal Controller Low cost DDC of Package Units Pumps Unit Ventilators Compatible with Both and Infinity Universal Inputs with Form A K and Analog Outputs Flexible Control Options Non Volatile Flash Memory Utmost Reliability Both Application and Operating Flash Memory Allows Easy Software Updates Modular Sleek Design Installation in Small View and Modify Information Optional Andover Sensor Display Local On Board Service Port i2867 contains five Form A Triac based Each Triac is ground referenced These can be used separately for on off or pulsed of lighting heat and fan units or be into Form K Tri state outputs 2 max for control of dampers and valves with free Triac output remaining Note Any two Triac outputs can be configured as a K output Outputs are rated for AC loads The i2867 also offers two 0 10V analog CAPABILITIES dynamic memory of the i2867 can be for any combination of programs alarming and data logging using the Andover Controls Plain English language Our object oriented Plain language with intuitive keywords provides easy method to tailor the controller to meet exact requirements Programs are entered the i2867 using the Continuum CyberStation SX 8000 Workstation or local user terminal are then stored in and executed by the multiple i2867s is inherently easy Plain English A complete copy of one i2867 can be loaded directly into other i2867s changing any point names or programs In channel assignments for the i2867 are to other Infinet devices such as the i2865 easy program conversion SENSOR INTERFACE i2867 provides a built in connection for Smart Sensor The Smart Sensor a 2 character LED display and a 6 button keypad that enables operators and to change setpoints balance VAV monitor occupancy status and turn on and off An enhanced version of the Sensor is also available with a 4 digit LCD that provides the following icons PM Setpoint Cool Heat CFM Fan OA and SP Drawing and Communications Drawing Drawing Sensor Drawing P E C I F I C AT I O N S Terminal Controller VAC 10 15 50 60 Hz Consumption VA Protection with 2 amp fuse MOV protected Real Time Clock Synchronized through Infinet by network Rating SPST CONTINUED single pole single throw SPST Form A any two consecutive outputs can be as one Tri state Form K analog outputs 0 10V 0.5A 24VAC Tested according to 20 mA AC Triac is ground referenced DC loads permitted Interface Through Infinet RS 485 field bus to Environment Type Backup Speed Length Media Error Checking Voltage Range Impedance Protection Resolution Accuracy 0 10 RH non x 3.50 x 2.50 D x 89W x 64 mm lbs 0.29 kg Open class IP 10 Flammability rating of or panel mount non rechargeable lithium Provides 5 years typical power failure backup of memory controller to 19.2K baud ft 1,220m standard for Infinet i2 module allows extension to longer and is required after every of 32 units on the network twisted shielded pair low cable Standard CRC 16 CyberStation and Infinity SX systems Universal inputs Voltage 0 5.115 VDC 30 to 230 34 to Digital on off Counter up to 4Hz 50 duty cycle 125 ms min pulse Current input 0 20 mA using 250 ohm resistor Smart Sensor Temperature Input 32 to 0 to 41 volts DC ohm to 5.120V or 5M ohm with pull resistor disabled VAC or 24 VDC temporarily on any channel transients Tested to EN61000 4 4 mV from 23 to 66 or from 10 to 150 0 10V Accuracy SPST 0 10V mA maximum 2K ohm minimum transients Tested to EN61000 4 4 sec for pulse width modulation mV resolution 100mV accuracy Sensor Port removeable screw terminal removeable screw terminal removeable screw terminal shrouded connector LEDS SWITCHES Indicator LEDS Active Data Data Pull up Resistor Switch per input SRAM 1MB FLASH 32 bit Coldfire LISTINGS 916 FCC CFR 47 Part 15 ICES 003 AS NZS 3548 and VCCI Class A CE Smoke Control System Equipment UUKL i2867 S Controls Corp Headquarters Brickstone Square Massachusetts 01810 USA 1 978 470 0555 Fax 1 978 470 0946 Controls Europe Road LE65 2UG England 44 1530 417733 44 1530 415436 Controls Germany Seerhein 8 Konstanz 49 7531 99370 49 7531 993710 Controls France Dolomites 2 Rue Roger Salengro Fontenay Sous Bois 33 1 53 99 16 16 33 1 53 99 16 15 Controls Poland 56 Krakow 48 126385500 48 126385501 Controls Asia 1201 02 Phase 1 Cheuk Nang Centre Hillwood Road Sha Tsui East Hong Kong 852 2739 5497 852 2739 7350 Controls Mexico Sur 1722 501 Florida D F 01030 Mexico 5255 5661 5672 5255 5661 5415 BUILDING SMART Balfour Beatty Company Andover Controls Corporation cid 127 All brand names trademarks and registered trademarks are the property of their respective holders DS I I2867 D

Related Files