Andover Controls Infilink 200 Comm
File Preview
Click below to download for free
Click below to download for free
File Data
Name | andover-controls-infilink-200-comm-3096725148.pdf |
---|---|
Type | |
Size | 795.86 KB |
Downloads |
Text Preview
I N F I N E T I I Infilink 200 Communications Unit Infinet II I2 Infilink 200 is an electronic repeater and a 5 port active for Andover Controls Infinet field bus designed to transmit RS 485 beyond the 31 device 4,000 foot 1.2 km limitation Andover field bus can be comprised of both Infinet and Infinet II controllers I2200 accepts twisted pair cabling at each of its five RS 485 ports A Infinet RS 485 input supplies up to four RS 485 output signals or Each spoke has the drive capability of up to 4,000 feet 1.2 km up to 57.6K baud with up to 31 separate devices attached conversion applications when existing phone lines are in place the RS 485 input can become a single RS 232 output for use with third short haul modems The four RS 485 output ports are still available using the RS 232 port Data transmission speeds for the I2200 are from 300 to 57.6K baud I2200 simplifies network troubleshooting by using LED indicators LEDs flash to indicate when the I2 is receiving and transmitting and RS 485 signals I2200 is provided with a hinged black 16 gauge cold rolled steel Installation is simplified by the use of detachable connectors all RS 485 ports AND DC MODELS AVAILABLE I2200 is available in two models The AC model is powered from a 115 230 VAC source A 24 VDC model is also available for where battery backed operation is required Note Only data rates up to 19.2K baud are presently supported on the Infinet network Five Port Active Hub for Field Bus Extends RS 485 Field Bus Beyond the Device 4,000 Feet 1.2 km Limitation AC and DC Models Available RS 485 to RS 232 Conversion Short Haul Modems Detachable RS 485 Provide Easy Switch Selectable Baud Rates 300 to 57.6K Baud AC Input Voltage Switch Full LED Indication for Easy Infilink 200 Dimensional Drawing with AC Power DC Power Layout P E C I F I C AT I O N S 200 Communications Unit Input Output Output barrier strip two piece terminal strip two piece terminal strip 25 pin female D connector LEDS SWITCHES Indicator LEDS COMM 1 5 TDs COMM 1 5 RDs COMM TD COMM RD is ON Active Data Data Data Data RATE AC or DC Power LISTINGS 916 FCC part 15 Class A ICES 003 Class A CE VAC 50 60 Hz switch or 24 VDC Consumption VA for AC model 1 W for DC model Protection with 2 A fuse MOV protected Environment 0 10 RH non x 7.500 x 2.370 D 210H x x 59D mm lbs 1.87 kg Type 1 style 16 GA C R S enclosure rating of UL94 5V IP 20 Speed Delay Length Media to 57.6K bps switch selectable to RS 485 0.5 Bit max not media to RS 485 0.5 Bit max not media four separate Infinet RS 485 each capable of connecting 31 and or 4000 feet 1.2 km twisted shielded pair approved capacitance cable 1 Chassis Ground 2 Transmit Data 3 Receive Data 4 Enabled 7 Signal Ground 9 12V 25 mA unregulated 10 12V 25 mA unregulated 20 Enabled Error Checking Standard CRC 16 Assignments for RS 485 to RS 232 Signal Controls Corp Headquarters Brickstone Square Massachusetts 01810 USA 1 978 470 0555 Fax 1 978 470 0946 Controls Ltd Road LE65 2UG England 44 1530 417733 44 1530 415436 Controls GmbH Seerhein 8 Konstanz 49 7531 99370 49 7531 993710 Controls S A Dolomites 2 Rue Roger Salengro Fontenay Sous Cedex France 33 1 53 99 16 16 33 1 53 99 16 15 Controls Asia 1201 02 Phase 1 Cheuk Nang Centre Hillwood Road Sha Tsui East Hong Kong 852 2739 5497 852 2739 7350 Controls Mexico Sur 1722 501 Florida D F 01030 Mexico 525 661 56 72 525 661 54 15 Balfour Beatty Company Andover Controls Corporation cid 127 All brand names trademarks and registered trademarks are the property of their respective holders DS I I2200 B