Andover Controls TCX 840 Series VAV Controller

File Preview
File Preview
Click below to download for free

File Data

Name andover-controls-tcx-840-series-vav-controller-7298460513.pdf
Type PDF
Size 650.79 KB
Downloads

Text Preview

Infinity 840 843 845 846 Terminal Control Unit Infinity TCX 840 family of intelligent programmable stand alone controllers offers versatility in Versatile DDC from Simple VAV to Digital Control of package units VAV boxes and other terminal unit applications The TCX 840 TCX 840 TCX 843 TCX 845 and TCX 846 features several combinations of universal inputs an pressure transducer Form A and Tri state outputs and analog outputs for flexible control the TCX 840 model with the I O configuration that meets your specific control needs The basic TCX 840 model provides low cost cooling only VAV control The TCX 843 with three outputs is perfect for VAV applications requiring reheat control The TCX 845 and TCX 846 full featured models With separate outputs for fan and staged heating and cooling control plus analog outputs for economizer control the TCX 845 and TCX 846 provide the perfect for package unit control oxide varistors and optocouplers provide 2500V isolation on each triac based output on all 840 models to ensure noise free operation and in most cases eliminate the need to install in the field The Infinet true peer to peer communications protocol provides the Infinity TCX 840 series with the to instantly communicate with an Infinity network controller such as the CX 9200 as well as the network of Andover Infinet field controllers Up to 254 TCX 840 series controllers can be to one CX series network controller E A T U R E S Package Unit Universal Inputs for Flexible Configurations Peer to Peer Communications Transparent Data Plain English Language Programming A and Tri State Outputs for and Bidirectional Control On Board Pressure Transducer Airflow Measurement Analog Outputs for Precise of Valves and Dampers Built in Varistors for Noise TCX 840 843 845 846 Terminal Control Unit to the Infinity TCX 840 series is handled via the Infinet bus a twisted pair half duplex RS 485 Communication is accomplished with a token passing protocol which provides full transparent data between all Infinity controllers on the network configuration consists of either two or four Universal inputs that accept voltage 0 5 VDC digital on off signals up to 4 Hz or temperature signals The TCX 840 843 and 846 also provide an on board airflow TCX 843 845 and 846 contain 5 Form A triac based outputs for on off or pulsed control of lighting heat and fan Adjacent outputs can also be configured up to two Tri state outputs providing bidirectional control of dampers and The TCX 845 and the TCX 846 also feature two analog outputs each to control devices such as valves dampers The basic TCX 840 model provides two Form A outputs configurable as a single Tri state output for reduced I O such as cooling only VAV control TCX 840 series controller can be configured to meet the exact distributed control requirements of your using Andover Controls powerful Plain EnglishTM programming language Programs are entered into an TCX 840 an SX 8000 workstation the LSX 280 Lap Top Service Tool or network controller The program is then stored in and by the TCX 840 The on board lithium battery keeps programs backed up in the event of a power failure multiple TCX 840s is inherently easy with Plain English A complete copy of one TCX 840 programs be loaded directly into other TCX 840s without changing any point names or programs The SX 8000 workstation this process even easier with its unique drag and drop feature CAPABILITIES dynamic memory of the TCX 840 can be allocated for any combination of Plain English control programs alarming and data logging Our object oriented language with intuitive keywords provides easy and programming In addition Plain English pre defined and customized functions and powerful math reduce programming time particularly for repetitive applications 840 Dimensional Drawing P E C I F I C A T I O N S VAC 50 60 Hz Individual transformer at each controller required included Consumption VA Protection with 2 amp pico fuse MOV protected 840 843 Software real time clock synchronized through Infinet by CX or Network Controller 845 846 Battery backed quartz clock synchronized through Infinet by CX or Network Controller Environment 140 0 60 10 95 RH non condensing 50 x 7.13 x 1.06 215.9 H x 181.1 W x 26.92 mm lbs 454 kg open class sheet metal IP 10 Clock Backup non rechargeable lithium battery Provides 3 years typical accumulated failure backup of RAM memory and real time clock Connector provided for battery Interface Infinity CX or CMX Network Controllers or LSX 280 Service Tool Speed to 19.2k baud Length ft 1,220m standard for Infinet InfiLink amplification module allows extension longer distances and is required after every group of 32 units on the network Media twisted shielded pair approved low capacitance cable Error Checking Standard CRC 16 P E C I F I C A T I O N S Cont Universal inputs Temperature 30 to 230 34 to 110 Digital on off up to 4Hz at 50 duty cycle 125 ms minimum pulse width Voltage VDC airflow sensor 0 to 1 W C Universal inputs 1 airflow sensor Universal inputs Universal inputs 1 airflow sensor ohm to 5.120V mV or 24VDC indefinitely on any single channel 1000V transients to IEC 801 4 15 mV 0.56 from 23 to 66 or 1 from 10 F to 150 Voltage Range 5.115 volts DC Input TCX 840 843 846 0 to 1 WC 0 249 Pa 0.005 WC 1.25 Pa 23 73 0.05 WC 12.5 Pa 23 73 Form A triac based outputs can be configured as 1 Form K Tri State output Form A triac based outputs can be configured up to 2 Form K Tri State outputs Form A triac based outputs can be configured up to 2 Form K Tri State outputs analog outputs 0 10V Form A triac based outputs can be configured up to 2 Form K Tri State outputs analog outputs 0 10V 1 A 24 VAC 1000 volt transients Tested according to IEC 801 4 30 MA AC triac outputs mA maximum 2K Ohm minimum impedance 1000 volt transients according to IEC 801 4 0.1 sec for pulse width modulation 50 mV resolution 100mV accuracy continued on back page 840 843 845 846 Impedance Protection Resolution Accuracy 840 843 845 846 Rating SPST 0 10V SPST 0 10 V P E C I F I C A T I O N S Cont Spade 250 Spade 250 Spade 250 Bus barrier strip 840 843 845 846 EPROM 32K RAM 128 bytes EEPROM Universal Inputs 1 Airflow 2 Form A Outputs or 1 Form K Universal Inputs 1 Airflow 5 Form A Outputs or 2 Form K Universal Inputs 5 Form A Outputs or 2 Form K 2 Analog Outputs Universal Inputs 1 Airflow 5 Form A Outputs or 2 Form K 2 Analog Outputs LISTINGS 916 FCC CE Controls Corporation Headquarters Brickstone Square Massachusetts 01810 USA 978 470 0555 cid 127 Fax 978 470 0946 Controls Ltd Road LE65 2UG England 01530 417733 cid 127 Fax 01530 415436 Controls GmbH Seerhein 8 Konstanz Germany 07531 99370 cid 127 Fax 07531 993710 Controls S A avenue de Fontainebleau Le Kremlin Bicetre 1 49 606363 cid 127 Fax 1 49 606271 Controls Asia Chinachem Golden Plaza Mody Road Tsimshatsui East Hong Kong 2739 5497 cid 127 Fax 2739 7350 Patent 4591967 Andover Controls Corporation subject to change without notice Andover Product Installation for exact installation instructions specifications

Related Files