Andover Controls TCX 850 Series VAV Controller

File Preview
File Preview
Click below to download for free

File Data

Name andover-controls-tcx-850-series-vav-controller-0746813529.pdf
Type PDF
Size 623.63 KB
Downloads

Text Preview

Infinity 850 TCX 851 TCX 852 TCX 853 TCX 855 Terminal Control Unit Infinity TCX 850 family of intelligent programmable stand alone controllers provides cost E A T U R E S E A T U R E S E A T U R E S E A T U R E S E A T U R E S Direct Digital Control of individual terminal units VAV boxes fan powered induction units ventilators heat pumps etc The Infinet true peer to peer communications protocol provides Infinity TCX 850 with the ability to instantly communicate with an Infinity network controller such the CX 9200 as well as the entire network of Andover Infinet field controllers Up to 254 TCX 850s be networked with the Infinity CX family of controllers to the Infinity TCX 850 is handled via the Infinet bus a twisted pair half duplex RS 485 interface Communica is accomplished with a token passing protocol which provides full transparent data transfer between all Infinity controllers the network the TCX controller with the input configuration that matches your application The TCX 850 has four full range inputs that accept voltage 0 5VDC digital on off counter signals up to 4 Hz or temperature signals plus a fifth which is an on board air flow sensor Three field adjustable potentiometers provide min max and setpoint adjustments TCX 851 comes without the on board airflow sensor for applications not requiring airflow measurement such as heat and fan coils It contains four Universal inputs but does not contain the three potentiometers TCX 852 contains two Universal inputs and the on board airflow sensor for reduced I O applications It does not contain three potentiometers TCX 853 is for dual duct VAV applications It contains two on board airflow sensors and six Universal inputs It does not the three potentiometers TCX 855 is identical to the TCX 850 with the exception that it contains a lower range 0 0.2 W C airflow sensor to lower air volume applications Stand Alone DDC for System Peer to Peer Communications Transparent Data Plain English Language Programming Universal Inputs for Flexible Configurations A and Tri State Outputs for and Bidirectional Control On Board Pressure Transducer Airflow Measurement Expandable I O Meets Additional Count Needs Battery Backup for Ten Years Power Failure of Memory TCX 850 851 852 853 855 Terminal Control Unit TCX 850 851 853 and 855 contain three Form A relay outputs for on off or pulsed control of lighting heat and fan One Tri State output provides bidirectional control of dampers and valves Optional analog output pneumatic output high voltage output modules are available TCX 852 contains one Form A output and one Tri State output for reduced I O applications EXPANSION TCX 850 851 853 and 855 contain the I O expansion port for the addition of low cost I O modules directly on the of the controller The family of modules includes the EMX 140 2 pneumatic outputs EMX 150 2 analog outputs 155 2 digital outputs and the EMX 160 8 digital inputs The EMX 170 Programmable Interface provides a low cost user interface and temperature sensor It contains an 8 character LCD display and six programmable that enable the user to view temperatures adjust setpoints and switch to occupied mode TCX 850 can be configured to meet the exact distributed control requirements of your application using Andover powerful Plain English programming language Programs can be activated within individual TCX 850s or any controller Programs are entered into an TCX 850 using an SX 8000 workstation the LSX 280 Lap Top Service Tool network controller The program is then stored in and executed by the TCX 850 The on board lithium battery keeps backed up in the event of a power failure multiple TCX 850s is inherently easy with Plain English A complete copy of one TCX 850 programs can be directly into other TCX 850s without changing any point names or programs The SX 8000 workstation makes this even easier with its unique drag and copy feature CAPABILITIES dynamic memory of the TCX 850 can be allocated for any combination of Plain English control programs scheduling and data logging Our object oriented language with intuitive keywords provides easy operation and program In addition Plain English pre defined and customized functions and powerful math capabilities reduce programming for repetitive applications P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S P E C I F I C A T I O N S 50 60 Hz Consumption Protection with 2 amp pico fuse MOV protected Real Time Clock through Infinet by CX or CMX Network Controller Environment 120 0 10 95 RH non condensing x 5 3 4 W x 2 3 4 D 228H x 146W x 070D mm 3.5lbs 1.6 Kg Type open class IP 10 non rechargeable lithium battery Provides 10 years typical power failure backup of RAM memory Interface Infinity CX or CMX Network Controller or LSX 280 Service Tool Speed to 19.2k baud Length ft 1,220m standard for Infinet InfiLink amplification module allows to longer distances and is required after every group of 32 units on the Media twisted shielded pair approved low capacitance cable Error Checking Standard CRC 16 Backup 850 851 852 853 855 Universal inputs Temperature 30 to 230 34 to 110 Digital on off up to 4Hz at 50 duty cycle 100 ms minimum pulse width Voltage 0 VDC airflow sensor 0 to 1 W C 3 On board adjustable potentiometers Universal inputs no airflow sensor no potentiometers Universal inputs 1 airflow sensor no potentiometers Universal inputs 2 airflow sensors no potentiometers Universal inputs 1 airflow sensor 0 to 0.2 W C On board adjustable potentiometers Protection Resolution Accuracy Input 850 855 Size Cont Cont P E C I F I C A T I O N S P E C I F I C A T I O N S Cont P E C I F I C A T I O N S Cont Cont P E C I F I C A T I O N S P E C I F I C A T I O N S Continued Voltage Range Volts DC Impedance ohm to 5.120V or 24 VDC indefinitely on any single channel 1500 volt transients 15 mV 0 5.115V range 1.0 over range of 0 to 120 over 17.8 to 48.9 0 to 1 inch W C 0.005 inch of water 23 5 of full scale or 0.05 inches water 0 to 0.2 inch W C single pole single throw SPST Form A relays 852 has 1 Form A output Form K Tri State relay Output Rating 24VAC 1500 volt transients Output Resolution sec for pulse width modulation Bus to optional I O Expansion Modules TCX 850 851 853 855 only barrier strip Spade 250 Spade 250 Bus removable terminal strip EPROM 32K RAM 128 Byte EEPROM LISTINGS 916 1076 864 UUKL FCC CE UUKL Compliance Controls Corporation Headquarters Brickstone Square Massachusetts 01810 USA 978 470 0555 cid 127 Fax 978 470 0946 Controls Ltd Road LE65 2UG England 01530 417733 cid 127 Fax 01530 415436 Controls GmbH Seerhein 8 Konstanz Germany 07531 99370 cid 127 Fax 07531 993710 Controls S A Dolomites 2 Rue Roger Salengro Fontenay Sous Cedex France 331 53 99 16 16 cid 127 Fax 331 53 99 16 15 Controls Asia 1201 02 Phase I Cheuk Nang Centre Hillwood Road Tsim Sha Tsui Hong Kong 852 2739 5497 cid 127 Fax 852 2739 7350 Controls Mexico Sur 1722 501 Florida D F 01030 Mexico 525 661 56 72 cid 127 Fax 525 661 54 15 Patent 4591967 Andover Controls Corporation subject to change without notice Andover Product Installation for exact installation instructions specifications

Related Files