Andover Controls UL Listed Proprietary Alarm System Installation Guide
File Preview
Click below to download for free
Click below to download for free
File Data
Name | andover-controls-ul-listed-proprietary-alarm-system-installation-guide-1204356789.pdf |
---|---|
Type | |
Size | 950.54 KB |
Downloads |
Text Preview
Controlling Tomorrow World Listed Proprietary Alarm Installation Guide Version Controls Corporation Manuals Online A or distribution forbidden cid 211 1995 by Andover Controls to change without notice No 30 3001 478 1995 cid 211 Controls Corporation Brickstone Square Massachusetts 01810 Rights Reserved NOTICE by the Engineering Department at Andover Controls Corporation product is subject to change without notice This document does not constitute any express or implied Andover Controls Corporation reserves the right to alter ca performance and presentation of this product at any time manual uses the following trademarks is a registered trademark of Brooks Power Systems is a registered trademark of Epson Corp 2000 is a registered trademark of Gateway 2000 is a trademark of Andover Controls Corporation is a registered trademark of Microsoft Corporation other product names mentioned herein are used for identification purposes and may be trademarks or registered trademarks of their respective companies Listed Proprietary Alarm System Installation Guide Manuals Online Controls Corporation Manuals Online Andover Controls UL Listed Proprietary Alarm System Installation Guide requirements and instructions for installing the alarm system on an Infinet This document refers you to additional Andover Controls Installation where appropriate Listed Proprietary Alarm System Installation Guide Manuals Online The Andover Controls Proprietary Alarm System consists of two major Central Supervisory Station Premise Control Units The Premise Control Units are responsible for initiating alarms and the status of these alarms over a supervised signaling bus to the Supervisory Station The Central Supervisory Station provides the focal point for all alarm An individual who is trained to interpret and acknowledge the alarms constantly monitors this station This station consists of three main The receiving unit The supervised station A printer printer provides a hard copy of all alarm events including where and when alarm occurred the type of alarm and when and by whom the alarm was Controls Corporation Manuals Online Installation Only individuals with the appropriate Andover Controls certifications shall the Andover Controls Systems of all alarm status changes must meet all of the following criteria Print on alarm Print on acknowledgment of alarm Print on return to normal Beep on alarm Beep on return to normal The maximum alarm delay must be less than 60 seconds 60 seconds 1 shows how the alarm priority levels must be set 1 Alarm Priority Levels Priority Alarm Type supervision where risk of injury to persons or or destruction of property may be involved Hold up or panic alarm Alarm Watchman Tour Alarm Supervision supervision where risk of injury to persons or or destruction of property is not involved Other supervisory services Listed Proprietary Alarm System Installation Guide Manuals Online Installation List 2 identifies the Andover Controls products listed in the UL Proprietary Alarm Systems category their role in the listing and the part numbers their detailed installation programmers guides 2 Andover Controls Product Listing Proprietary Alarm Systems Category Number Description of Central Station of Central Station Control Control Control Control Control of Central Station Support Installation Guide Installation Guide Installation Guide Installation Guide Installation Guide Installation Guide Installation Guide Programmers Guide Configuration Guide Controls Corporation Manuals Online Supervisory Station Installation Requirements Locate the equipment in a secure indoor location on the property being Maintain the ambient temperature at 55 cid 176 95 cid 176 F Supply the HVAC equipment controlling the ambient with a twenty four hour power source the loss of AC power by an audible and visual signal Requirements 3 lists Central Supervisory Station equipment Because a redundant Cen Supervisory Station is required you must duplicate all the equipment Your Supervisory Station equipment must consist of two each of the items 3 Central Supervisory Station Equipment Description SX8000 version 2.1 loaded into a Gateway 2000 P5 120 Computer PC with a Power Cord and a Media Card Vivitron Monitor with Power Cord Keyboard Microsoft Mouse Epson LQ570 Printer with Power Cord Brooks BN6 6 surge suppressor with On Off switch Circuit Breaker Power Indicator and Power Cord Andover Controls Corporation CX9200 with the appropriate such as ENL additional requirements see the appropriate installation guide Listed Proprietary Alarm System Installation Guide Manuals Online Installation Requirements The power service and all wiring must comply with the National Electrical computer Item 1 and the printer Item 5 must plug into the surge strip receptacle surge suppressor Item 6 requires a standard 120Vac 15 A 60 Hz see the Andover Controls CX9200 Installation Guide part number 30 for the detailed CX9200 Item 7 power requirements All of the Central Supervisory Station equipment must be supplied with a hour standby power source The loss of AC power shall be by an audible a visual signal additional requirements please see the appropriate installation guide Supervisory Station With the equipment located in its proper place setup and connect the printer the PC using the detailed instructions provided with the equipment Connect the CX9200 to the 3Com media card installed in the PC using the length of Ethernet 10 base2 cable and correct terminations detailed communication information and additional set up information please the Andover Controls Infinity Network Configuration Guide part number and the CX9200 Installation Guide part number 30 3001 347 Controls Corporation Manuals Online Installation Control Units Requirements see the appropriate installation guide Requirements All Premise Control Units must be powered from a UL Listed Burglar Alarm Power APHV or a Power Supply UL Listed for Fire Alarm Use UTRZ capable providing four hours of standby power The power supply must also provide a dry contact closure for AC power failure This output must be wired to a supervisory input and must signal a status change to Central Supervisory Station This signal must be programmed for the service level additional requirements please see the appropriate installation guide Control Units All Premise Control Units must be installed with cabinet tamper switches Leads from all supervisory input circuits keypads and card reader circuits shall of conductors insulated from and surrounded by a shielding conductive grounded at one end The maximum loop impedance is 100 ohms All supervisory inputs must be located in the same room or area as the Premise Unit and must use the end of line resistors provided for the Premise Control Andover Controls part number 01 0010 666 additional instructions please see the appropriate installation guide Listed Proprietary Alarm System In