UL, ULC, CSFM Listed; NYC Fire Dept, Approved* Fire Control Units Automatic Extinguishing Deluge and Preaction Sprinkler System Releasing Control control using the Autocall 4010ES Fire Alarm Control to provide: Coverage for multiple areas of Automatic Extinguishing Release and/ Deluge and Preaction Sprinkler System Release including audible of events Control of compatible Listed/Approved valves and actuators Releasing Appliance Circuits (RACs) by connecting Notification Circuits (NACs) to Suppression Release Peripherals (SRP) for supervision and control Four, 3 Amp NACs in the control unit for use with SRPs and required appliances Additional actuator circuit control and additional NACs are available 4009 Addressable NAC Extenders and Suppression Peripherals Escalation of Events: Temporal or 20 March Time pattern for first cross-zone alarm 120 bpm March Time pattern indicates releasing timer active On steady indicates releasing timer expired and actuator is activated Note: Requires NACs dedicated to conventional horn control (not operation) with strobes controlled on separate NACs IDNet NAC Extenders provide: Up to eight NACs for notification requirements and for NAC input to Release Peripherals Control is via IDNet addressable communications Suppression Release Peripheral (SRP) Dual Input Control Logic: Dual input control logic requires that both IDNet communications and an activated NAC are present to initiate the desired RAC output provides wiring supervision to the actuator including of coil continuity and short circuit supervision to the coil module Release Peripheral control features: An onboard DC-DC regulator compensates for voltage drops to the and ensures proper control circuit voltage over a wide range Provides a single RAC for control of actuators for up to 2 A using a 3 A input (1 A using a 2 A NAC input) system components: 4010ES Series control unit with Releasing Appliqu Dedicated NAC output from 4010ES (or compatible NAC Extender) Coil supervision module, one per RAC Maintenance Switch, one per RAC Abort Switch connected via an addressable interface module combined with Suppression Release Peripherals, the 4010ES Fire Alarm Control Unit provides actuator supervision and control use in automatic extinguishing, and deluge or preaction releasing Hazard area initiating and notification devices are controlled either conventional or addressable circuits per standard 4010ES The necessary releasing system logic is implemented within 4010ES control unit as required for the local application. Extinguishing Release Systems systems automatically activate electrically controlled actuators the release of a fire extinguishing agent (such as dry chemical, water foam, CO2, or clean agent) in response to fire detection device as determined by programming of the host fire alarm control unit. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings ,7300-2269:0507, 7165-2269:0541, 7165-2269:0542 and 7300-2269:0567 for allowable values and/or conditions concerning material presented in this document. Additional listings be applicable; contact your local product supplier for the latest status. Rev. 11 7/2021 Automatic Extinguishing Deluge and Preaction Sprinkler System Releasing Control Extinguishing Release Systems are required to have minimum of 24 hours of standby power. Initiating devices must be for the application, and may be wired either Class A B. Control actuators must be electrically compatible with the control circuits and power supplies, and are wired Class B to provide coil Agency listings UL 864 – Control Units, System (UOJZ); Control Unit Accessories, Fire Alarm (UOXX); Control Units, Releasing Device Service Smoke Control System Equipment (UUKL) UL 1076 – Proprietary Alarm Units (APOU) UL 1730 – Smoke Detector Monitors and Accessories (UULH) UL 2017 – Emergency Alarm System Control Units, CO detection (FSZI); Equipment Man
UL, ULC, CSFM Listed; NYC Fire Dept, Approved* Fire Control Units Automatic Extinguishing Deluge and Preaction Sprinkler System Releasing Control control using the Autocall 4010ES Fire Alarm Control to provide: Coverage for multiple areas of Automatic Extinguishing Release and/ Deluge and Preaction Sprinkler System Release including audible of events Control of compatible Listed/Approved valves and actuators Releasing Appliance Circuits (RACs) by connecting Notification Circuits (NACs) to Suppression Release Peripherals (SRP) for supervision and control Four, 3 Amp NACs in the control unit for use with SRPs and required appliances Additional actuator circuit control and additional NACs are available 4009 Addressable NAC Extenders and Suppression Peripherals Escalation of Events: Temporal or 20 March Time pattern for first cross-zone alarm 120 bpm March Time pattern indicates releasing timer active On steady indicates releasing timer expired and actuator is activated Note: Requires NACs dedicated to conventional horn control (not operation) with strobes controlled on separate NACs IDNet NAC Extenders provide: Up to eight NACs for notification requirements and for NAC input to Release Peripherals Control is via IDNet addressable communications Suppression Release Peripheral (SRP) Dual Input Control Logic: Dual input control logic requires that both IDNet communications and an activated NAC are present to initiate the desired RAC output provides wiring supervision to the actuator including of coil continuity and short circuit supervision to the coil module Release Peripheral control features: An onboard DC-DC regulator compensates for voltage drops to the and ensures proper control circuit voltage over a wide range Provides a single RAC for control of actuators for up to 2 A using a 3 A input (1 A using a 2 A NAC input) system components: 4010ES Series control unit with Releasing Appliqu Dedicated NAC output from 4010ES (or compatible NAC Extender) Coil supervision module, one per RAC Maintenance Switch, one per RAC Abort Switch connected via an addressable interface module combined with Suppression Release Peripherals, the 4010ES Fire Alarm Control Unit provides actuator supervision and control use in automatic extinguishing, and deluge or preaction releasing Hazard area initiating and notification devices are controlled either conventional or addressable circuits per standard 4010ES The necessary releasing system logic is implemented within 4010ES control unit as required for the local application. Extinguishing Release Systems systems automatically activate electrically controlled actuators the release of a fire extinguishing agent (such as dry chemical, water foam, CO2, or clean agent) in response to fire detection device as determined by programming of the host fire alarm control unit. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings ,7300-2269:0507, 7165-2269:0541, 7165-2269:0542 and 7300-2269:0567 for allowable values and/or conditions concerning material presented in this document. Additional listings be applicable; contact your local product supplier for the latest status. Rev. 11 7/2021 Automatic Extinguishing Deluge and Preaction Sprinkler System Releasing Control Extinguishing Release Systems are required to have minimum of 24 hours of standby power. Initiating devices must be for the application, and may be wired either Class A B. Control actuators must be electrically compatible with the control circuits and power supplies, and are wired Class B to provide coil Agency listings UL 864 – Control Units, System (UOJZ); Control Unit Accessories, Fire Alarm (UOXX); Control Units, Releasing Device Service Smoke Control System Equipment (UUKL) UL 1076 – Proprietary Alarm Units (APOU) UL 1730 – Smoke Detector Monitors and Accessories (UULH) UL 2017 – Emergency Alarm System Control Units, CO detection (FSZI); Equipment Man