Home » Autocall 4100 Series Graphic Annunciator Modules; LED_Switch Modules and 24 Point I_O Graphic Module

File preview
Click the button below to download immediately for free
Show text preview
UL, ULC, CSFM Approved* Accessories, LED Annunciators Series Graphic Annunciator Modules; LED/Switch Modules and 24 Point I/O Graphic modules for LED and switch control of custom graphic panels including: A100-7401, 24 Point I/O Graphic Modules with points selectable as switch inputs or LED outputs A100-7402, 64 Switch and 64 LED Driver Module with 32 on-board LED A100-7403, 32 Point LED Driver Modules A100-7404, 32 Point LED Switch Input Modules compatibility: For use with Autocall 4007ES, 4010ES, and 4100ES series fire alarm units door mounting options are available: Semi-flush or surface mount cabinets in beige or red, with or without a Interface modules can be mounted in the same cabinet as the graphic or mounted nearby Plate-mounted for mounting in cabinet by others Interface modules are UL listed for use in agency listed custom graphic panels and status supervision: Supervised remote unit interface communications (RUI) require a twisted, wire pair (some applications may require shields) to the alarm control unit (power is supplied via a second wire pair) Multiple annunciator module types can be connected to same wiring Convenient wiring connections are via pluggable terminal blocks listed to Standard 864 for: Fire Detection and Control (UOJZ) Smoke Control Service (UUKL) Control. remote annunciator graphic control modules complement 4007ES, 4010ES and 4100ES (and other installed legacy panels) providing LED/lamp/relay drivers and switch inputs to allow custom displays to be designed for specific facility requirements, such as smoke control (UUKL) systems. Wiring is minimized by signaling line (SLC) communications that also provides supervision. the event of communications loss, a trouble will be displayed at fire alarm control panel and can also be identified at the remote if desired. Flexibility. packaging flexibility, these modules are plate-mounted, allowing with vended graphics assemblies. These modules also convenient terminal block wiring connections and use compact cable connectors for multiple module interconnection. 1: Fire Alarm Control Unit Connected to a Graphic Annunciator and a Remote LCD Annunciator This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7120-2269:0546 for allowable and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Rev. 7 01/2020 Series Graphic Annunciator Modules; LED/Switch Modules and 24 Point I/O Graphic Module Control Module Descriptions 24 Point I/O Graphic Module: 24 Points, selectable as either a switch input or a lamp/relay driver output Switch monitoring includes: unsupervised, supervision for opens, supervision for opens or shorts, and supervised monitoring of HOA (hand/off/auto) Switches can be momentary or maintained, 2 position or 3 position, maximum distance is 2500 ft (762 m), or 65 from the module Each LED/lamp/relay driver is rated at 150 mA @ 24 VDC per point, inrush is current limited for compatibility with incandescent bulbs (relays need to diode suppressed at the relay coil) maximum distance is 600 ft (183 m), or 2 from the module LED/lamp/relay driver outputs are supervised for open circuits and can be set as on continuous, or pulsed at a slow or fast rate Additional inputs are included for communicating a remote power supply trouble and for lamp testing, the module can also be configured to provide indication of communications loss 64/64 LED/Switch Controller Module: Support for up to 64 switches and 64 LEDs (switches are unsupervised) Includes 32 LED driver outputs on-board for direct LED connection Full capacity is achieved by using a A100-7403, 32 Point LED Driver Module, and two A100-7404, 32 Point Switch Modules Multiplexed LED drivers provide 40 mA peak, 5 mA average, 60 Hz rate, 12.5% duty cycle for direct LED drive and can be steady on, or slow or fast LEDs are supervised for open circuits, LED and switch module connections are supervised
UL, ULC, CSFM Approved* Accessories, LED Annunciators Series Graphic Annunciator Modules; LED/Switch Modules and 24 Point I/O Graphic modules for LED and switch control of custom graphic panels including: A100-7401, 24 Point I/O Graphic Modules with points selectable as switch inputs or LED outputs A100-7402, 64 Switch and 64 LED Driver Module with 32 on-board LED A100-7403, 32 Point LED Driver Modules A100-7404, 32 Point LED Switch Input Modules compatibility: For use with Autocall 4007ES, 4010ES, and 4100ES series fire alarm units door mounting options are available: Semi-flush or surface mount cabinets in beige or red, with or without a Interface modules can be mounted in the same cabinet as the graphic or mounted nearby Plate-mounted for mounting in cabinet by others Interface modules are UL listed for use in agency listed custom graphic panels and status supervision: Supervised remote unit interface communications (RUI) require a twisted, wire pair (some applications may require shields) to the alarm control unit (power is supplied via a second wire pair) Multiple annunciator module types can be connected to same wiring Convenient wiring connections are via pluggable terminal blocks listed to Standard 864 for: Fire Detection and Control (UOJZ) Smoke Control Service (UUKL) Control. remote annunciator graphic control modules complement 4007ES, 4010ES and 4100ES (and other installed legacy panels) providing LED/lamp/relay drivers and switch inputs to allow custom displays to be designed for specific facility requirements, such as smoke control (UUKL) systems. Wiring is minimized by signaling line (SLC) communications that also provides supervision. the event of communications loss, a trouble will be displayed at fire alarm control panel and can also be identified at the remote if desired. Flexibility. packaging flexibility, these modules are plate-mounted, allowing with vended graphics assemblies. These modules also convenient terminal block wiring connections and use compact cable connectors for multiple module interconnection. 1: Fire Alarm Control Unit Connected to a Graphic Annunciator and a Remote LCD Annunciator This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7120-2269:0546 for allowable and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Rev. 7 01/2020 Series Graphic Annunciator Modules; LED/Switch Modules and 24 Point I/O Graphic Module Control Module Descriptions 24 Point I/O Graphic Module: 24 Points, selectable as either a switch input or a lamp/relay driver output Switch monitoring includes: unsupervised, supervision for opens, supervision for opens or shorts, and supervised monitoring of HOA (hand/off/auto) Switches can be momentary or maintained, 2 position or 3 position, maximum distance is 2500 ft (762 m), or 65 from the module Each LED/lamp/relay driver is rated at 150 mA @ 24 VDC per point, inrush is current limited for compatibility with incandescent bulbs (relays need to diode suppressed at the relay coil) maximum distance is 600 ft (183 m), or 2 from the module LED/lamp/relay driver outputs are supervised for open circuits and can be set as on continuous, or pulsed at a slow or fast rate Additional inputs are included for communicating a remote power supply trouble and for lamp testing, the module can also be configured to provide indication of communications loss 64/64 LED/Switch Controller Module: Support for up to 64 switches and 64 LEDs (switches are unsupervised) Includes 32 LED driver outputs on-board for direct LED connection Full capacity is achieved by using a A100-7403, 32 Point LED Driver Module, and two A100-7404, 32 Point Switch Modules Multiplexed LED drivers provide 40 mA peak, 5 mA average, 60 Hz rate, 12.5% duty cycle for direct LED drive and can be steady on, or slow or fast LEDs are supervised for open circuits, LED and switch module connections are supervised