Datasheet Peripherals Relay IAM (Individual Addressable Module) with Unsupervised Input ULC, CSFM Listed, FM * point operation provides an unsupervised input and a relay in a single package using only one address: Typical applications are for fan control with single unsupervised status monitoring For use with Autocall 4007ES, 4010ES, 4100ES Fire Alarm Control providing IDNet communications details: Input provides unsupervised monitoring of normally open, dry contacts Total wiring distance to supervised contacts is up to 500 ft (152 m); for wiring applications Low power latching relay design allows IDNet communications to both data and module power Relay is set to OFF on initial power up and upon loss of IDNet ratings) Form C relay output is rated 2 A @ 30 VDC, and 0.5 A @ 120 VAC sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be viewed after Listed to Standard 864 Address Dual Point Module. A4090-9119 Relay IAM allows a compatible Autocall fire alarm panel IDNet communications channel to monitor an input contact closure with one point and control an relay with the other point, both from a compact module a single address. Module power is supplied from the IDNet channel eliminating the need for separate power Device Description. input circuit and relay operation are controlled independently and be disabled separately. Point association is determined at the panel. At the host panel display, the device address is designated a single hardware location (such as 1-1). The individual points are “sub-points” and are layered underneath (such as 1-1-1 and 1: Relay IAM with Unsupervised (shown approximately 1/2 size) Selection Adapter and Trim Plates IAM with Unsupervised Input plate to fit 4 11/16″ (119 mm) square electrical semi-flush box surface box trim plate with LED viewing includes mounting screws; steel Applications Package. smoke control applications, this module provides an efficient for fan control with single status feedback. The monitor point feedback from a single set of unsupervised contacts (such as a switch or pressure switch) allowing the host panel to track the result the requested relay control operation. Applications. monitor and control points can be applied for a variety of associated independent operations. Flexible programming abilities at the host can provide the association logic required for a wide variety of fire utility operations. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0505 and for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Rev. 8 03/2021 Relay IAM (Individual Addressable Module) with Unsupervised Input Reference 2: information For Fire Alarm applications, locate loads within 3 ft (1 m) of contacts. Power Limited Contact Ratings: A @ 30 VDC, resistive loads A @ 30 VDC, inductive loads Non-Power Limited Contact Ratings: A @ 120 VAC, resistive loads A @ 120 VAC, inductive loads to specifications for additional information) Refer to Installation Instructions 574-875AC for detailed installation information. A4090-9119 Relay IAM with Input is illustrated. Wiring Distances: Up to 2500 ft (762 m) from host control panel. Up to 10,000 ft (3048 m) total wiring distance, including “T” taps. Refer to Installation Instructions 574-875AC for detailed installation information. A4090-9119 Relay IAM with Input is illustrated. 2 Rev. 8 03/2021 Relay IAM (Individual Addressab
Datasheet Peripherals Relay IAM (Individual Addressable Module) with Unsupervised Input ULC, CSFM Listed, FM * point operation provides an unsupervised input and a relay in a single package using only one address: Typical applications are for fan control with single unsupervised status monitoring For use with Autocall 4007ES, 4010ES, 4100ES Fire Alarm Control providing IDNet communications details: Input provides unsupervised monitoring of normally open, dry contacts Total wiring distance to supervised contacts is up to 500 ft (152 m); for wiring applications Low power latching relay design allows IDNet communications to both data and module power Relay is set to OFF on initial power up and upon loss of IDNet ratings) Form C relay output is rated 2 A @ 30 VDC, and 0.5 A @ 120 VAC sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be viewed after Listed to Standard 864 Address Dual Point Module. A4090-9119 Relay IAM allows a compatible Autocall fire alarm panel IDNet communications channel to monitor an input contact closure with one point and control an relay with the other point, both from a compact module a single address. Module power is supplied from the IDNet channel eliminating the need for separate power Device Description. input circuit and relay operation are controlled independently and be disabled separately. Point association is determined at the panel. At the host panel display, the device address is designated a single hardware location (such as 1-1). The individual points are “sub-points” and are layered underneath (such as 1-1-1 and 1: Relay IAM with Unsupervised (shown approximately 1/2 size) Selection Adapter and Trim Plates IAM with Unsupervised Input plate to fit 4 11/16″ (119 mm) square electrical semi-flush box surface box trim plate with LED viewing includes mounting screws; steel Applications Package. smoke control applications, this module provides an efficient for fan control with single status feedback. The monitor point feedback from a single set of unsupervised contacts (such as a switch or pressure switch) allowing the host panel to track the result the requested relay control operation. Applications. monitor and control points can be applied for a variety of associated independent operations. Flexible programming abilities at the host can provide the association logic required for a wide variety of fire utility operations. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0505 and for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. Rev. 8 03/2021 Relay IAM (Individual Addressable Module) with Unsupervised Input Reference 2: information For Fire Alarm applications, locate loads within 3 ft (1 m) of contacts. Power Limited Contact Ratings: A @ 30 VDC, resistive loads A @ 30 VDC, inductive loads Non-Power Limited Contact Ratings: A @ 120 VAC, resistive loads A @ 120 VAC, inductive loads to specifications for additional information) Refer to Installation Instructions 574-875AC for detailed installation information. A4090-9119 Relay IAM with Input is illustrated. Wiring Distances: Up to 2500 ft (762 m) from host control panel. Up to 10,000 ft (3048 m) total wiring distance, including “T” taps. Refer to Installation Instructions 574-875AC for detailed installation information. A4090-9119 Relay IAM with Input is illustrated. 2 Rev. 8 03/2021 Relay IAM (Individual Addressab