UL, ULC, CSFM Listed, FM Approved* or dual channel intrinsically safe, transformer isolated modules: 2081-9062, single channel 2081-9063, dual channel requirements of National Electrical Code Articles 500-517 Hazardous Locations: Classes I, II, and III Divisions 1 and 2 Groups A, B, C, D, E, F, and G with Autocall intrinsically safe manual stations and apparatus: Refer to Compatibility Reference for compatible product details compatible smoke detector model Product selection summary is detailed in Intrinsically Safe Product accessories (ordered separately): A2975-9218, red cabinet with solid door and lock 2081-9061, module installation kit Intrinsically Safe Modules are for use with Autocall control to make initiating device circuit wiring safe for use in locations hazardous concentrations of flammable gases or other materials exist. The intrinsically safe module is an isolated, power-limited that limits the output current to a level below ignition for defined by NEC Articles 500-517 for Classes I, II, and III, 1 and 2, Groups A, B, C, D, E, F, and G. Considerations installation of intrinsically safe modules requires strict adherence to compatibility lists and must be in accordance with all product instructions and applicable codes and wiring practices. all applicable references thoroughly before completing the safe design. Alarm System Accessories Safe Devices Single and Dual Channel Isolated Barrier Modules 1: Barrier Modules 2081-9062 and 2081-9063** Voltage (Vin) Current (Iin) Voltage < 23.7 V > 23.7 V Current Temperature Humidity VDC to 35 VDC mA maximum, limited by module = Vin – (400 x Iin) – 0.7 V = Vin – (400 x Iin) current 40 mA circuit current 65 mA to 120 (0 to 49 to 85% RH maximum @ 86 (30 1/2 in. H x 4 1/4 in. W (including block) x 13/16 in. D mm x 108 mm x 21 mm) Cabinet; required, ordered separately Installation Kit; required, ordered separately in. W x 8 3/8 in. H x 3 1/2 in. D mm x 213 mm x 89 mm) for barrier module mounting (35 DIN rail type), mounting hardware, drawing, and required end-of-line Refer to Intrinsically Safe Product Selection for listing of approved parameters and allowable wiring distances. Safe Barrier Module Compatibility 2081-9062 and 2081-9063 intrinsically safe modules report as a current limited condition. Intrinsically Safe applications are not compatible with Alarm operation. Reference 3: Zone Adapter Modules (ZAMs) B, for use with compatible fire alarm control panels; communications 4: Compatible Initiating Devices Action Station Stations Series Apparatus device which does not store or generate more than 1.2 V, 100 mA, 20 (typically a dry contact heat detector or pushbutton switch) Smoke Detector (NOTE: Not FM approved, but tested compatible with IDCs listed) IDCs Intrinsically Safe Smoke Detector SLR-E-IS with Hochiki Safe Detector Base YBN-R/4-IS; Note: Five (5) per circuit; Available Hochiki America 1: Intrinsically Safe Barrier Module in Cabinet, shown with cover removed, and conduit shown for reference only This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0507 and for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. AC2081-0018 Rev. 6 09/2021 Safe Devices Single and Dual Channel Isolated Barrier Modules R
UL, ULC, CSFM Listed, FM Approved* or dual channel intrinsically safe, transformer isolated modules: 2081-9062, single channel 2081-9063, dual channel requirements of National Electrical Code Articles 500-517 Hazardous Locations: Classes I, II, and III Divisions 1 and 2 Groups A, B, C, D, E, F, and G with Autocall intrinsically safe manual stations and apparatus: Refer to Compatibility Reference for compatible product details compatible smoke detector model Product selection summary is detailed in Intrinsically Safe Product accessories (ordered separately): A2975-9218, red cabinet with solid door and lock 2081-9061, module installation kit Intrinsically Safe Modules are for use with Autocall control to make initiating device circuit wiring safe for use in locations hazardous concentrations of flammable gases or other materials exist. The intrinsically safe module is an isolated, power-limited that limits the output current to a level below ignition for defined by NEC Articles 500-517 for Classes I, II, and III, 1 and 2, Groups A, B, C, D, E, F, and G. Considerations installation of intrinsically safe modules requires strict adherence to compatibility lists and must be in accordance with all product instructions and applicable codes and wiring practices. all applicable references thoroughly before completing the safe design. Alarm System Accessories Safe Devices Single and Dual Channel Isolated Barrier Modules 1: Barrier Modules 2081-9062 and 2081-9063** Voltage (Vin) Current (Iin) Voltage < 23.7 V > 23.7 V Current Temperature Humidity VDC to 35 VDC mA maximum, limited by module = Vin – (400 x Iin) – 0.7 V = Vin – (400 x Iin) current 40 mA circuit current 65 mA to 120 (0 to 49 to 85% RH maximum @ 86 (30 1/2 in. H x 4 1/4 in. W (including block) x 13/16 in. D mm x 108 mm x 21 mm) Cabinet; required, ordered separately Installation Kit; required, ordered separately in. W x 8 3/8 in. H x 3 1/2 in. D mm x 213 mm x 89 mm) for barrier module mounting (35 DIN rail type), mounting hardware, drawing, and required end-of-line Refer to Intrinsically Safe Product Selection for listing of approved parameters and allowable wiring distances. Safe Barrier Module Compatibility 2081-9062 and 2081-9063 intrinsically safe modules report as a current limited condition. Intrinsically Safe applications are not compatible with Alarm operation. Reference 3: Zone Adapter Modules (ZAMs) B, for use with compatible fire alarm control panels; communications 4: Compatible Initiating Devices Action Station Stations Series Apparatus device which does not store or generate more than 1.2 V, 100 mA, 20 (typically a dry contact heat detector or pushbutton switch) Smoke Detector (NOTE: Not FM approved, but tested compatible with IDCs listed) IDCs Intrinsically Safe Smoke Detector SLR-E-IS with Hochiki Safe Detector Base YBN-R/4-IS; Note: Five (5) per circuit; Available Hochiki America 1: Intrinsically Safe Barrier Module in Cabinet, shown with cover removed, and conduit shown for reference only This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7300-2269:0507 and for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local product supplier for the latest status. AC2081-0018 Rev. 6 09/2021 Safe Devices Single and Dual Channel Isolated Barrier Modules R