Autocall 4004R Suppression Releasing Panel for Automatic Extinguishing, Deluge and Preaction Sprinkler Control
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4004r-suppression-releasing-panel-for-automatic-extinguishing-deluge-and-preaction-sprinkler-control-6875203914.pdf |
---|---|
Type | |
Size | 1.40 MB |
Downloads |
Text Preview
Datasheet Control Fire Alarm Systems Suppression Releasing Panel for Automatic Extinguishing Deluge and Preaction Control ULC CSFM Listed FM alarm control panel designed specifically for suppression operation with Four initiating device circuits IDCs Two notification appliance circuits NACs Two releasing appliance circuits RACs Two special purpose monitor inputs SPMs that accept manual release and manual abort request for Agent Release systems and and supervisory for Preaction or Deluge systems Three auxiliary relays with selectable functions Easily selected activity timing options release operation includes Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection Combined agent release and preaction operation IDCs are selectable for cross zoning or for activation from a single input Short circuit RAC supervision Compatible with Listed Approved 24 VDC or 2 12 VDC series actuators Escalation of Events Single Audible Appliance Tone Stage 1 activates Temporal or 20 bpm Time pattern Stage 2 activates 120 bpm March Time pattern to release timer active Release activates On Steady to indicate timer expired and actuator is activated Dual Audible Appliance Control Single Hazard RAC 2 provides third NAC for dedicated Stage 1 Bell control NACs 1 2 indicate as On Steady interface provides Status LEDs per circuit for Alarm Trouble and Supervisory where Acknowledge Alarm Silence and System Reset Operating mode selection and timer selections when in programming system components Coil supervision module A2081 9046 one per RAC Maintenance Switch one per RAC Abort Switch to UL Standard 864 and ULC Standard S527 for Suppression Release 4004R Suppression Release provide conventional fire alarm control circuits and are equipped the features required for a wide variety of single or dual hazard release applications Capabilities include automatic agent release and deluge and preaction sprinkler control Requires Software Revision 4.01 or higher 1 Suppression Release One Line System Reference Drawing I O Capabilities Four IDCs allow for either four separately zones or two cross zoned connections Two SPMs allow manual inputs for release or abort for waterflow and or release abort and pressure depending on system type releasing appliance circuits RACs supervise to the actuator coils activate the actuators when required The two NACs and the three auxiliary relays provide status condition information Program Selections The operator panel has a program mode allows selection of panel operation type and detailed operating using an easily selected sequential programming operation Log The last 50 events are stored in non volatile memory This is accessed by connecting a technician computer to the port which is also used to set the date and time Feature Description Panel The operator panel has alarm and trouble status LEDs for each input and output visible through the locking door refer to Operator Panel Function Unlocking the door access to the Acknowledge Alarm Silence and System Reset button switches to Specifications for more information This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0525 7272 2269 0510 7150 2269 0540 7300 2269 0555 7165 2269 0542 and 7165 2269 0544 for allowable values and or conditions concerning material presented in this document listings may be applicable contact your local Autocall product supplier for the latest status Rev 8 03 2021 Suppression Releasing Panel for Automatic Extinguishing Deluge and Preaction Sprinkler Control Relay Module Operation 1 activates on a common trouble associated with its hazard or a trouble Class B IDCs provide coverage for either two cross zoned areas four separately zoned areas IDCs are capable of supporting up to 30 current limited smoke detectors or electronic heat detectors Reference Information Compatible Autocall Detectors and other Components as well as manual stations and other compatible closure initiating devices IDCs are capable of Class A operation an optional adapter module and can be programmed as Style C or open initiates a trouble for use with current limited devices Single hazard agent release applications monitor pressure switches IDC 3 and tamper switches with IDC 4 Class B Special Purpose Monitoring Circuits SPMs are for manual release or abort waterflow and supervisory release abort and pressure depending on system type Inputs normally open switches An abort switch stops release while and upon deactivation the release operation occurs after a time delay Manual release inputs override abort switches and the release after selectable delays of from 0 to 30 seconds in 5 increments For Dual Hazard applications current limited abort is required SPMs are programmable as Style C and capable of A operation with the optional adapter module Class B NACs are provided for reverse polarity notification operation each rated 2 A Class A operation is available the optional adapter module NAC operation is selectable per Synchronized strobe operation requires a separate A4905 Strobe Synchronization Module see Product Selection and a steady on non coded input from the NAC Class B Releasing Appliance Circuits RACs Rated 2 A each circuits are dedicated to operating release control actuators RAC timing is selectable as no cutout 45 seconds or 1 3 3.5 4 5 7 21 25 34 44 or 64 minutes For bell horn strobe single hazard RAC 2 functions as a third NAC NAC 3 Power Output Two sets of output terminals are provided for continuous operation and the other for resettable operation for 750 mA combined Resettable terminals are provided for 4 wire detector power Panel Auxiliary Relay Outputs Three relay outputs are selectable as normally open or normally closed rated 2 A 30 0.35 p f inductive Relay 1 Trouble is energized when Normal and is de energized a common Trouble condition Relays 2 and 3 respond differently depending on the system type whether single or dual hazard Typical functions are Single Hazard Operation Aux Relay 2 is the common Alarm relay Relay 3 can be selected to indicate pre discharge release time started common supervisory waterflow or pressure switch relay on the system type Dual Hazard Operation Aux Relay 2 is for Hazard Area 1 common Aux Relay 3 is for Hazard Area 2 common Alarm Supply and Battery Charger During alarm the power supply 3 A at 25.5 VDC filtered and regulated The temperature battery charger provides 27.5 VDC for charging batteries to 12.7 Ah suitable for up to 90 hour standby and 10 minutes of A A4081 Series external battery cabinet with charger can be used more battery backup see battery selection below Modules and Accessories Relay Module A004 9860 provides four additional relays hazard applications will require two modules for auxiliary relay Each relay module has a manual disconnect switch that relays 2 through 4 Trouble Relay 1 is not controlled Relay are required to be connected to a 15 A maximum circuit Relay specifications are detailed in Specifications 3 2 Switch 2 activates on a common alarm associated with its hazard 3 selected for original operation activates for pressure waterflow switch or release timer as required per application hazard specific or activates with the second zone for cross systems hazard specific Original operation allows direct panel if required 3 selected for enhanced operation software 4.01 or higher to indicate pre discharge supervisory or waterflow application 4 activates when the hazard specific RAC activates or with switch input application specific Circuit Class A Adapter Module A004 9864 This module two Class B circuits to Class A operation It consumes no current and is compatible with IDCs SPMs and NACs Up to modules may be mounted within the 4004R cabinet Switches For manual abort requests these abort switches are with or without a built in 1.2 k 1 W resistor and are mounted single gang stainless steel plates Abort switches are connected to SPM inputs per system requirements