Autocall 4006 Series Fire Alarm Control Panels Providing up to Ten IDCs and Four NACs
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4006-series-fire-alarm-control-panels-providing-up-to-ten-idcs-and-four-nacs-5827140639.pdf |
---|---|
Type | |
Size | 1.59 MB |
Downloads |
Text Preview
Datasheet Fire Alarm Control Panels Series Fire Alarm Control Panels Providing up to Ten IDCs and Four NACs areas requiring from five to ten initiating zones the Autocall Series fire alarm control panels provide flexible initiating circuit extensive programmable control capability and LCD circuit specific 20 character custom labels 1 Beige Standard Control Panel ULC CSFM Listed FM panel operator convenience features Wide viewing angle 2 x 20 40 character alphanumeric LCD and LEDs provide convenient panel status information Operation is programmable using a multi function keypad and the LCD or via service computer PC RS 232 service port provides upload download PC access for panel and event history logs Software updates are via PC download Convenient library of standard custom label terms Standard on board DACT provides Contact ID 3 1 4 2 BFSK and SIA WALKTEST silent or audible system test Voltage and current for both the battery charger and the battery can displayed at the front panel LCD Standard Initiating Device Circuits IDCs Five Class B IDCs with optional expansion to ten all with individual Monitor 2 wire or 4 wire initiating devices including TrueAlarm smoke disable Optional Class A Adapter Module Standard Notification Appliance Circuits NACs Class A or Class B outputs with solid state overcurrent protection per each rated for 2 A strobe control Selectable for Autocall SmartSync two wire horn strobe control or Power Supply Provides 3 A maximum nominal 24 DC Automatic input power selection operates with 120 VAC or 240 VAC 50 60 Hz On board temperature compensated battery charger for up to 12.7 Ah in cabinet UL and ULC and up to 25 Ah batteries in separate UL only standard features Programmable Active Status Reminder Two auxiliary relays IDCs NACs and Relay outputs are power limited AC input battery and City Circuit Module outputs are non power limited Available with beige or red cabinet UL listed to Standard 864 option modules Door mounted 24 LED annunciator standard on ULC models 3 A Expansion Power Supply with two on board 2 A NACs that operate same as standard NACs Expansion IDC module with five Class B IDCs Class A IDC Adapter Module City Interface Module and Auxiliary Relay Remote LCD and LED Switch Annunciators This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0569 7270 2269 0511 7272 2269 0510 7300 2269 0567 7165 2269 0514 and 7300 0026 0381 for allowable values and or conditions concerning material presented in this document listings may be applicable contact your local Autocall product supplier for the latest status Rev 12 03 2021 Series Fire Alarm Control Panels Providing up to Ten IDCs and Four NACs Feature Details Class B IDCs are each capable of supporting up to 30 Autocall current limited smoke detectors or electronic heat detectors see Reference Compatible Autocall Peripherals as well as manual stations and other compatible contact closure initiating devices IDCs are capable of A operation with an optional adapter module and can be programmed as Style C short or open initiates a trouble for use with current limited only 2 A On Board NACs provide conventional reverse polarity operation selectable as Class A or Class B with electronic control and overcurrent Operation is selectable for synchronized strobe or SmartSync horn strobe two wire operation Horn control can be selected at the panel Temporal pattern coding Steady On Slow March Time of 20 beats per minute BPM or Fast March Time of 120 BPM When selected for SmartSync horn strobe control March Time produces 60 BPM 24 VDC Auxiliary output provides up to 500 mA for system use Auxiliary output current is counted for total power supply capacity Auxiliary Relay Outputs Two relay outputs are available selectable as normally open or normally closed rated 2 A 30 VDC per below Relay 1 is normally assigned to General Alarm operation but is programmable see Additional Programming Feature Details Relay 2 Trouble is energized when Normal and is de energized with a Trouble condition Dual Line DACT Operation can be selected for Contact ID SIA 3 1 4 2 and BFSK formats Reporting includes Alarm Supervisory Trouble AC Failure Operation includes automatic 6 hour test and programmable power fail report delay Supply and Battery Charger DC power output is 3 A 24 VDC for panel use The temperature compensated battery charger sealed lead batteries only is rated for up to 25 Ah batteries per UL 864 and up to 12.7 Ah per ULC S527 Up to 12.7 Ah batteries fit in the cabinet larger require an external cabinet Panel electronics can measure and display voltage and current for the power supply batteries and the battery standard and expansion power supply Depleted battery trouble is monitored and annunciated and depleted battery cutout can be selected battery status monitor supervises charger operation Feature Details Power Supply Provides 3 A total 24 VDC two additional 2 A NACs and an additional auxiliary power output of 500 mA Output is the same as on the standard power supply IDC Module Provides 5 additional Class B IDCs with operation the same as the standard IDCs Relay Module Provides 10 programmable relays jumper selectable as N O or N C Contacts are rated 2 A 30 VDC Typical application is track status of each IDC See Relay Operation Modes for relay program options A Adapter Module Converts 5 IDCs from Class B to Class A operation Two modules can be mounted for use with the Expansion IDC Module Circuit Modules These modules are available with or without on board disconnect switches depending on local requirements either type can disconnected through the front panel under password control Connections are for Remote Station reverse polarity or Municipal Master local Reporting includes Alarm Supervisory and Trouble Selection 1 Control Panel fire alarm control FM Feature Class B IDCs 2 B Class A NACs A power supply battery charger DACT VAC 50 60 Hz 2 Option Modules Power Supply 3 A with 2 NACs 120 240 VAC 50 60 Hz IDC Module 5 Class B IDCs Relay Module 10 relays selectable as either N O or N A Adapter Module converts 5 IDCs from Class B to Class A Circuit Module with disconnect switch Circuit Module without disconnect switch up to of each as up to maximum one if 2 Rev 12 03 2021 Series Fire Alarm Control Panels Providing up to Ten IDCs and Four NACs 3 Accessories semi flush trim kit 1 7 16 37 mm wide includes four corners and trim pieces for top and sides semi flush trim kit 1 7 16 37 mm wide includes four corners and trim pieces for top and sides External Battery Cabinet for up to 25 Ah batteries mounts close nippled to control panel dimensions 16 1 4 W x 13 1 2 H x 5 3 4 D 413 mm x 343 mm x 146 mm depth for 25 Ah effective 7 2005 4 Batteries 12 Volt select one battery model per system standby requirements order quantity of two Ah Ah Ah cabinet mount A009 9801 External Battery Cabinet UL only to Installation Instructions 579 704AC for additional information Input Ratings Voltage Current Current with Power 5 Power Ratings VAC 60 Hz 220 230 240 VAC 50 60 Hz auto select A maximum 120 VAC input 1.5 A maximum 240 VAC input A maximum 120 VAC input 3 A maximum 240 VAC input Supply Output Rating Charger Current A maximum 24 VDC in alarm see NAC details on Detailed NAC Ratings compensated charger is rated for up to 25 Ah per UL 864 up to 12.7 Ah per ULC S527 mA with 5 IDCs fully loaded tone alert silenced trouble LED on 6 Standard Circuit Ratings NOTE Total DC current 3 A maximum Appliance Circuits NACs See Detailed NAC Ratings Current Current Resistor Supported