Autocall 4007ES Fire Detection and Control with Addressable Initiation and Addressable Notification; International
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4007es-fire-detection-and-control-with-addressable-initiation-and-addressable-notification-international-7285130649.pdf |
---|---|
Type | |
Size | 10.40 MB |
Downloads |
Text Preview
Datasheet Fire Control Units Fire Detection and Control with Addressable Initiation and Addressable Notification ULC CSFM Listed FM NYC Fire Approved Standard panel SLC provides up to 100 addressable points optional loop expansion modules provide an additional isolated with short circuit isolation for the IDNet 2 channel each loop module also provides an additional 75 addressable points the IDNet 2 channel capacity for a total of up to 250 addressable feature summary Current and previous panel configuration are both maintained in on memory to allow easy selection of desired revision An internal Ethernet service port is available for service computer to perform configuration updates downloads and report downloads and system software updates Internal USB interface allows a memory stick thumb drive to store job update revised jobs and panel software and save detailed reports from the panel modules and connections include Fire alarm network interface card NIC for ES Net Peer to Peer network communications supports either Class B or X operation Up to two additional IDNet 2 addressable device output loop with 75 additional point capacity each Front mounted 48 LED annunciator with custom label inserts Dual Class A IDNAC Isolator DCAI Remote LED annunciator support through remote unit interface RUI port for use with unshielded twisted pair wiring UTP Eight point zone relay modules individually selectable as IDC or relay 2 A at 30 VDC resistive Alarm relays and auxiliary relays Dual RS 232 ports for printer PC annunciator or third party interface City connections with or without disconnect switch 4003EC Voice Control Panels 4009 Series IDNAC Repeaters Battery brackets for seismic area protection mechanical Compact red or platinum cabinet for convenient surface or semi flush rated NEMA 1 and IP30 Listings reference UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service UL 2017 Emergency Alarm System Control Units CO detection FSZI ULC S559 Central Station Fire Alarm System Units DAYRC ULC S527 Control Units System Fire Alarm UOJZC Control Unit System Fire Alarm UOXXC Control Units Releasing Service SYZVC 1 4007ES FACU front view with Autocall ES Net standard combination of addressable initiation and notification in 109 mm diagonal color touchscreen display Convenient and intuitive user interface provides detailed system status individual point information Supports dual language selection including unicode character A custom background display appears when operation is normal a 3 A IDNAC signaling line circuit SLC output power that provides enhanced power delivery to addressable appliances A constant 29 VDC source voltage is maintained during alarm even battery operation This allows strobes to operate at higher with lower current and ensuring a consistent current draw and drop margin under both primary power and secondary battery Efficiencies include lower strobe currents wiring distances up to two three times farther than with conventional notification support more appliances per IDNAC SLC and smaller gauge wiring This installation and maintenance savings with high assurance appliances will operate as normal during worst case alarm IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert notification appliances and remote 4009 IDNAC to extend power and wiring distance and provide for up to addressable notification appliances Power supply provides battery backup charging of up to 33 Ah up to Ah for cabinet mounted batteries and up to 33 Ah batteries for in close nippled remote battery cabinet isolated IDNet 2 addressable initiating device SLC Provides built in short circuit isolation for monitoring and control of analog sensors and IDNet communications devices for use either shielded or unshielded twisted or untwisted single pair outputs are Class A or Class B This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7300 2269 0559 7272 2269 0537 and 7165 2269 0536 for allowable values and or conditions concerning material presented in this document NYC Fire Dept COA 6264 Additional may be applicable contact your local Autocall product supplier for the latest status AC4007 0002 Rev 20 11 2021 Fire Detection and Control with Addressable Initiation and Addressable Notification screen reference Menu screen provides navigation to the function Buttons A B and C have functions Alarm screen identifies alarms with custom labels Use the arrows to allow through the list series fire detection and control units fire alarm control units FACUs provide extensive installation and service features with point and module capacities suitable a wide range of system applications FACUs are configurable for or networked fire control operation The convenient and color touchscreen provides easy access for typical system actions and for detailed system review or configuration with password control to limit user access 2 addressable initiation communications and IDNAC addressable communications are standard features Refer to data sheet for 4007ES FACUs providing conventional notification panel compatibility with ES Net ES Network ES Net is a next generation IP based fire network uses industry standard network technology and infrastructure and for simplified network upgrades easy terminal connectivity and IP transfer between nodes and advanced network diagnostics can upgrade ES fire FACUs to operate on an ES network by adding ES Net NIC to the panel more detailed information on ES Net refer to data sheet and talk to your local Autocall product supplier interface status information the locking door closed the glass window allows viewing of the status LEDs The user interface is a 4.3 in 109 mm diagonal touchscreen LCD with separate status LEDs see Figure 2 indicators describe the general category of activity being displayed the LCD provides more detail Authorized user can unlock the door gain access to the control functions and scroll through the display for detail display with LED status indicators 2 Touchscreen display with LED status indicators Seismically compliant under the State of California Statewide of Housing and Development OSHPD Special Seismic SSC program guidelines Refer to Simplex Seismic Guide 579 1213AC and Battery Brackets for Seismic Activity AC2081 0019 for details Trouble screen identifies troubles with custom labels arrows allow navigation the list Log screen allows review past troubles with time stamp point details shown Information screen allows of point details arrows allow through the information Access Login screen controls to panel operations as per panel interface and software features Convenient and detailed operator information is easily accessed using logical menu driven touchscreen display with password access Multiple automatic and manual diagnostics for maintenance reduction Alarm and Trouble History Logs up to 1000 entries for each 2000 total are available for viewing from the display or for printing to a printer or downloaded to a service computer Module level ground fault searching assists installation and service by and isolating modules with grounded wiring WALKTEST silent or audible system test performs an automatic self test cycle and supports up to eight WALKTEST groups Install Mode allows grouping of multiple troubles for uninstalled and devices into a single trouble condition typical with future expansion with future equipment and devices grouped into single trouble operators can more clearly identify events from the and occupied areas 2