Autocall 4009 IDNAC Repeater; Power and Distance Extender
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4009-idnac-repeater-power-and-distance-extender-4362758091.pdf |
---|---|
Type | |
Size | 1.59 MB |
Downloads |
Text Preview
TrueAlert Addressable Notification IDNAC Repeater Power and Distance Extender ULC CSFM Listed FM IDNAC Repeaters provide enhanced power delivery to ES addressable notification appliances by IDNAC SLCs Output voltage in alarm is maintained by an efficient switching at 29 VDC during both AC input and battery backup allowing strobes to operate at lower current With lower current strobes and regulated output voltage wiring can be extended 2 to 3 times that of conventional notification loading can be increased or smaller wire gauge can be used resulting in installation savings with high assurance that appliances operate during normal system testing will operate during worst alarm conditions IDNAC Repeaters receive an IDNAC SLC input and provide a 3 A SLC output to extend SLC distance and power Appliance control and address limit remains with the host IDNAC panel Repeater status is communicated to the control panel system diagnostics and also locally indicated Repeater output extends supervisory capacity by up to 139 additional loads or 3 A Input SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B output with internal for up to four 4 T tapped output branches Class A requires A009 9814 Class A Adapter Operation requires one IDNAC SLC address Repeaters can be as one in series or up to five 5 in parallel AC power input is 120 VAC or 220 240 VAC 50 60 Hz auto select An on board battery charger is provided with low AC battery selectable per Repeater required for ULC listed Operation is compatible with TrueAlert ES and TrueAlert addressable appliances and accessories Available with platinum or red cabinet Listed to UL 864 and ULC S527 wiring options are available Wiring options include Class B multiple branch up to 4 output Class A extension and Class A riser to Class B branches or a Class A loop When the Repeater is part of a Class A loop from the IDNAC SLC source up to twice the distance for the loop is available Class A loop requires A009 9814 Class A Adapter 1 IDNAC Repeater Extends and Current of IDNAC SLC A Adapter A009 9814 Required when extending a Class A loop or to provide a Class A local SLC output Operation provides short circuit isolation between input and output for improved IDNAC SLC survivability battery Charger Power supply charges up to 12.7 Ah batteries for in cabinet mounting up to 25 Ah batteries with model A009 9801 external battery auxiliary output A 200 mA 29 VDC constant auxiliary output is available operation is during battery backup This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0553 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 7 07 2021 IDNAC Repeater Power and Distance Extender IDNAC SLCs fire alarm control panels with IDNAC SLC outputs provide individual address and control of TrueAlert and TrueAlert ES addressable notification When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC use of 4009 IDNAC Repeaters extends the SLC with an additional 3 A of SLC current and up to 139 unit loads of additional supervisory capacity IDNAC SLCs a constant 29 VDC source voltage is maintained in alarm even during battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with conventional notification or support for more appliances per IDNAC SLC or of smaller gauge wiring or combinations of these benefits all providing installation and maintenance savings with high assurance that appliances operate during normal system testing will operate during worst case alarm conditions wiring configurations wiring configurations are available to provide a variety of system solutions Class B branch extension Class A loop extension and Class A riser to B branch extension or Class A loop output B branch input wiring B branch input wiring allows T tapped connections to up to five 5 parallel connected 4009 IDNAC Repeaters Each Repeater has on board terminal connections for up to four 4 output branch circuits and additional branch circuits can be externally T tapped as required Refer to Reference Class B Input with Class B Branch Circuit Outputs for additional details A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be Repeater communicates and repeats bi directionally allowing Class A loop operation to be maintained in the event of an open circuit This wiring requires use of the A009 9814 Class A adapter Refer to Wiring Reference Class A Loop Extension for additional details A Riser to Class B Branches or Class A Loops applications requiring a combination of wiring types a Class A riser can drive up to five 5 4009 IDNAC Repeaters with each Repeater capable of either single or multiple Class B branch output s or a Class A loop output In this wiring application the Repeater does not repeat in the Class A loop it is connected as an appliance with Class A in out wiring To create a Class A loop output the Repeater must be equipped with a A009 9814 A Adapter Refer to Wiring Reference Class A Riser Input with Class A Loop and Class B Branch Outputs for additional details Selection Color IDNAC Repeater with cabinet provides a single 3 A IDNAC SLC output 200 mA auxiliary power output battery charger 120 240 VAC 50 60 Hz input auto select 1 IDNAC Repeater Selection 2 Aftermarket Accessories installed on site select per system requirements A Adapter Module mounts on repeater controller board required for Class A output semi flush box trim semi flush box trim 7 16 37 mm wide four corners and trim pieces for top bottom sides will need to be cut to fit 4009 IDNAC Repeater cabinet 3 External Accessories select per system requirements TrueAlert Communications Isolator Battery Cabinet for 25 Ah batteries to data sheet AC4905 0001 for details W x 13 H x 5 D 413 mm x 343 mm x 146 mm refer to sheet AC2081 0006 for details 4 Battery Selection select battery size per system requirements two batteries are required for 24 VDC operation Ah Battery 12 VDC Ah Battery 12 VDC Ah Battery 12 VDC A009 9801 External Battery Cabinet 2 Rev 7 07 2021 Reference Class B Input with Class B Branch Circuit Outputs IDNAC Repeater Power and Distance Extender 2 Reference 3 Rev 7 07 2021 Reference Class A Loop Extension IDNAC Repeater Power and Distance Extender 3 Reference 4 Rev 7 07 2021 Reference Class A Riser Input with Class A Loop and Class B Branch Outputs IDNAC Repeater Power and Distance Extender IDNAC Repeater Mounting and Module Placement Reference 4 Reference 5 Reference 5 Rev 7 07 2021 IDNAC Repeater Power and Distance Extender IDNAC Repeater Specifications Range VAC Current VAC Current Input Ratings 5 Input Ratings VAC 50 60 Hz or 220 230 240 VAC 50 60 Hz 10 15 auto select A A VDC minimum address 4 unit loads 6 24 VDC Requirements for Battery Calculations Currents Currents mA mA Appliances mA each A maximum with 3 A IDNAC SLC load and 200 mA Auxiliary load actual alarm current depends on connected and appliances and devices 7 Output Ratings Load current voltage is from x output current voltage is on when in Alarm SLC Output Special Application Repeater Loading and SLC Usage Output A maximum 29 VDC for Special Application appliances