Autocall 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC FM Approved Fire Alarm Controls IDNet NAC Extender for Control with IDNet Communications or Conventional NACs flexibility You can mount the 4009 IDNet NAC Extender to a compatible dedicated host panel or remotely for convenient distribution Multiple operation modes and multiple connection further increase location flexibility information For additional operation detail and information refer to Installation Instructions 574 181 and wiring diagram 842 068 additional notification appliance circuit NAC capacity flexible operation modes and power limited design Class B NACs are standard and have the following features Rated 2 A each for conventional reverse polarity 24 VDC notification and providing multiple operation modes You can select the NAC to synchronize Autocall visible notification flashes Control support for TrueAlert non addressable notification appliances with SmartSync two wire control mode control options IDNet addressable communications from a 4007ES 4010 4010ES or Fire Alarm Control Panel 4100U requires revision 11 software or higher for compatibility requires revision 2 software or higher for compatibility Control from one or two conventional 24 VDC NACs with multiple control options communications control benefits Status monitoring and individual NAC control using a single address for 4009 IDNet NAC Extender IDNet Device Level earth fault location support operation is available with either input choice 8 A power supply or battery charger Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in cabinet Provides status monitoring of battery input power and earth faults Rated 8 A for Special Application appliances including 4901 4903 and 4906 Series horns strobes horn strobes and speaker Rated 6 A for Regulated 24 DC appliance power 4009 IDNet NAC Extender modules IDNet Communications Repeater provides Class B or Class A output IDNet Communications Fiber Optic Receiver Repeater available as B or Class X Four additional Class B NACs rated 1.5 A for Special Application 1 A for Regulated 24 DC appliance power Class A Two Circuit Adapter Module Listed to Standard 864 Accessories communication fiber optic transmitters For applications requiring the data integrity available with fiber optic Available as Class B or Class X Mountable in standard six gang electrical box battery cabinet for 18 Ah batteries compliance Complying with the notification requirements of ADA Americans with Disabilities Act may require more notification power than is available within the fire alarm control panel additional power is required a 4009 IDNet NAC Extender can up to 8 A of NAC power with up to eight supervised reverse NACs Additional listings may be applicable contact your local product supplier for the latest status 1 4009 IDNet NAC Extender reference drawing Rev 16 06 2021 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs and operation information addressable communications compatible You can control up to ten 4009 IDNet NAC Extenders for each 4007ES 4010ES or 4100ES IDNet channel You can control each output NAC individually for general alarm or selective area notification requiring only one point address each Extender You can also control Individual Extender NACs manually from the host panel IDNet controlled extenders inform the host panel of using IDNet communications IDNet repeaters IDNet communications can be repeated with the optional IDNet Repeater Module or with the optional Fiber Optic Module Up to 100 of the IDNet channel points can be repeated once Refer to Typical IDNet connection example and 4009 IDNet NAC specifications for details Repeated IDNet communications also support the device level earth fault location utility of the host panel control applications You can control the 4009 IDNet NAC Extender directly from the NAC for applications where an existing or new NAC needs additional power You can connect one or two NACs from the same or different host fire alarm control panels to control the IDNet NAC Extender output NACs Multiple control selections provide flexible operation Refer to Hardwire Control Connection Information for detail Alarms from the host panel activate four or optionally eight 4009 IDNet NAC Extender NACs to extend the alarm 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions including earth faults Extenders wired to conventional indicate a trouble by opening the path to the NAC end of line resistor but retaining the ability to respond to alarms LEDs located on the 4009 NAC Extender main circuit board also annunciate individual troubles Refer to Service diagnostic features for more diagnostic information selection 1 Standard models see note ULC listed model A009 9201 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F requires battery as detailed on data sheet AC2081 0019 IDNet NAC Extender with 4 Class B NACs 8 A power supply VAC input VAC input VAC input 2 Optional modules for on site installation four point NAC module rated 1.5 A Special Application 1 A for Regulated 24 DC appliance power Class B Class A adapter for two NAC outputs Repeater output is Class A or Class B B A IDNet Class X fiber maximum as required four maximum either an IDNet Repeater or a Fiber Optic as required one transmitter can connect one receiver 3 Battery selection select battery size using system requirements 4 External accessories select using system requirements Optic Receiver Appliqu for door Ah Battery 12 VDC Ah Battery 12 VDC Ah Battery 12 VDC Fiber Optic B operation X operation battery cabinet for up to 18 Ah batteries beige resistor harnesses see data sheet A4081 0003 for details batteries are required 24 VDC operation in six gang electrical box refer to IDNet fiber optic transmitter information for mounting details Class B Fiber Transmitter Rev C or higher NOT COMPATIBLE with Class B Fiber Receiver Rev J 1 4 in W x 13 1 2 in H x 5 3 4 in D 413 mm x mm x 146 mm series 2 Rev 16 06 2021 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs IDNet connection example You can connect up to 10 4009 IDNet NAC Extenders using 4007ES 4010ES or 4100ES IDNet channel IDNet communications can be repeated once and pass through only one series connected repeater or one fiber optic receiver 2 Typical IDNet connection example 3 Rev 16 06 2021 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs fiber optic system connections 3 Typical fiber optic system connections You can connect up to 10 4009 IDNet NAC Extenders for each 4007ES 4100ES or 4010ES IDNet communications can be repeated only once pass through only one series connected repeater or one fiber optic receiver Fiber optic transmitters connect to only one receiver in a 4009 IDNet Extender Control Connection Information Input Selections The 4009 IDNet NAC Extender can be selected to Track input NAC operation or to provide a locally generated code selectable using NAC input If selected for local coding NAC outputs can be either Temporal Coded or 60 Beats min March Time Coded One code selection per extender Input must be on continuous with Alarm Additionally NAC outputs can be selected to provide the Autocall strobe synchronization signal This signal synchronizes the flashes of synchronized but is ignored by free run strobes and audible devices Strobes are for operation by noncoded NACs can select NAC input to NAC output control for standard and optional NACs Refer to the following table 5 Conventional NAC Output Operation Options 1 and 2 5 and 6 3 and 4 7 and 8 1 4 5 8 6 SmartSync NAC Output Operation 1 8 Control Function Control Control NAC outputs 1 8 1 2 1 2 4 Rev 16 06 2021 IDNet NAC Extender for Control with ID

Related Files