Datasheet Fire Control Units Addressable Fire Detection and Control Basic Control Unit Modules and ULC CSFM Listed FM Approved with Autocall ES Net network system features Models available with Color ES Touch Screen Display or Monochrome 2 x 40 Character Display Capacity for up to 1000 addressable IDNet points or up to 1000 MX Loop points and up to 127 VESDA SLI points with up 2000 points of annunciation and up to 20 internal and external card CPU assembly includes dedicated compact flash memory for on site information storage and convenient Ethernet service port 8 A power supply with up to 2 A of auxiliary power and battery charger for up to 110 Ah batteries UL or up to 50 Ah batteries ULC Ah max in one bay control cabinet 50 Ah max with A100 0650 shelf in two bay control cabinet 4 onboard Class A or B 3 A NACs and one programmable auxiliary output rated for 2 Remote annunciator module support through Remote Unit Interface communications port either Class B or Class A operation 48 LED Control Unit mount annunciation provides 40 Red and 8 Yellow LEDs select models optional LED kits are available for LED configurations Main System Supply 2 and door mounted modules and options include City Connect Module Alarm Relay module Battery brackets for seismic area protection block space modules include Fire Alarm Network Interface Card NIC for ES Net Peer to Peer network communications supports either Class B or X operation Ethernet connectivity options include ES Net Network Interface Card Network Interface Card BNIC and BACpac Ethernet Portal Dual RS 232 Module for printer or third party interface VESDA Air Aspiration High Level Interface Serial DACT Additional IDNet and MX Loop addressable channels 8 Point Zone Relay Module 4 Point Auxiliary Relay Module with or without Feedback with Autocall remotely located 4098 9757 QuickConnect2 TrueAlarm smoke sensors 4009 IDNet NAC Extenders 4009A A4081 Series 110 Ah Battery Chargers 4100 7400 Series Graphic Annunciators A4606 9102 Remote LCD Annunciator A100 9400 Series Remote ES Screen Displays A100 9400 Series Remote InfoAlarm Command and A602 Series Status Command Units SCU and Remote Units RCU Annunciators IP communicator compatibility 1 1 Bay Cabinet with 2 x 40 Monochrome LCD Display 2 1 Bay Cabinet with with 2 x 40 LCD Display and LED Annunciation 3 2 Bay Cabinet with 2 x 40 Monochrome LCD Display Agency listings UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service Smoke Control System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UULH UL 2017 Emergency Alarm System Control Units CO detection FSZI Equipment Management QVAX ULC S527 Control Units System Fire Alarm UOJZ7 Control Unit System Fire Alarm UOXX7 Control Units Releasing Service SYZV7 ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm System Units APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 series fire detection and control units series fire detection and control units provide leading operator and service features for customer applications the mid range addressable fire alarm systems market An onboard port provides fast external system communications to expedite and service activity Dedicated compact flash memory provides secure on site system information storage of job configuration files This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7272 2269 0509 7272 2269 0537 7165 2269 0541 and 7165 2269 0542 for allowable values and or conditions concerning material presented in this document Refer to Tables 3 and for applicable listings at time of publication Additional listings may be applicable contact your local Autocall product supplier for the latest status Refer to specific product listings in tables 2 and 3 AC4010 0006 Rev 23 11 2021 Addressable Fire Detection and Control Basic Control Unit Modules and Accessories design variety of functional modules are available to meet specific system Selections allow control units to be configured for either or Networked fire control operation description The mounting box provides convenient stud markers for drywall and nail hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance exactly where required The hinged user interface control unit easily opens for internal access NACs are mounted directly on power supply assemblies providing wiring loss compact size and readily accessible Modules are power limited except as noted such as relay modules Doors include tempered glass inserts boxes and doors are available in Box and door or retainer assemblies are included with basic control or red assemblies Cabinet assembly is rated NEMA 1 and IP 30 Cabinet assembly design has been seismic tested and is certified to and CBC standards as well as to ASCE 7 categories A through F battery brackets as detailed on data sheet Battery Brackets for Activity Applications AC2081 0019 unit hardware Controller and Main System Supply 2 in the upper section of the 4010ES cabinet See the loading diagrams in Cabinet one and two bay loading reference Block Space Option Cards Block Space Option Cards mount to the left of the 4010ES Main Supply 2 In two bay cabinets block space option cards also below the 4010ES ESS 4010ES options 4010ES City Connect module or the optional Alarm Relay module directly to the Main System Supply 2 These options are mutually battery compartment battery compartment is located in the bottom of the 4010ES The cabinet allows for up to 33 Ah battery capacity for 1 bay and 50 Ah for 2 bay systems 50 Ah batteries also require the of A100 0650 battery shelf 13 identifies mounting locations for optional 4010ES modules access almost dirty Dirty TrueAlarm sensor maintenance alerts service and status reports TrueAlarm magnet test indication appears as distinct test abnormal on display when in test mode TrueAlarm sensor peak value performance report Install Mode allows grouping of multiple troubles for uninstalled and devices into a single trouble condition Module level ground fault searching assists installation and service by and isolating modules with grounded wiring Recurring Trouble Filtering allows the control unit to recognize and log recurring intermittent troubles such as external ground faults but only sends a single outbound system trouble avoid nuisance communications WALKTEST silent or audible system test performs an automatic self test cycle peripheral devices 4010ES is compatible with an extensive list of remote peripheral including printers and both conventional and addressable including TrueAlarm analog sensors device control 4010ES provides standard addressable device communications IDNet compatible devices Using a two wire communications circuit can interface individual devices such as manual fire alarm stations sensors conventional IDC zones and sprinkler waterflow to the addressable controller to communicate their identity and facilitates the display of the location and condition of the device on the operator interface LCD and on remote system Additionally control circuits such as fans or dampers may individually controlled and monitored with addressable devices operation addressable device on the communication channel is continuously for status condition such as normal off normal alarm or trouble Both Class B and Class A pathway operation are Sophisticated poll and response communication techniques supervision integrity and allow for T tapping of the circuit for B operation Devices with