Autocall 4010ES Addressable Fire Detection with IDNAC, Fire Alarm Control Unit and Accessories; International
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4010es-addressable-fire-detection-with-idnac-fire-alarm-control-unit-and-accessories-international-5748963021.pdf |
---|---|
Type | |
Size | 5.41 MB |
Downloads |
Text Preview
Datasheet Fire Control Units Fire Detection with IDNAC Fire Alarm Control Unit and Accessories ULC CSFM Listed FM NYC Fire Approved with Autocall ES Net fire alarm network system includes Models available with Color ES Touch Screen Display or Monochrome 2 x 40 Character Display Capacity for up to 1000 addressable IDNet points and up to 127 Air Aspiration Systems interface points with up to 2000 points annunciation Capacity for up to 20 internal and external card addresses CPU assembly includes dedicated compact flash memory for onsite information storage an Enhanced System Supply ESS that provides power battery charging 6 A output Dual 3 A on board IDNAC signaling line circuits SLCs with enhanced delivery to addressable notification appliances An IDNAC SLC maintains a constant 29 VDC source voltage during even during battery operation allowing strobes to operate higher voltage with lower current and ensuring a consistent draw and voltage drop margin under both primary power and battery standby Efficiencies include lower strobe currents wiring distances up to two three times farther than with conventional notification support more appliances for each IDNAC SLC ability to use smaller wiring all with installation and maintenance savings with high that appliances that operate during normal system testing during worst case alarm conditions IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert notification appliances and remote 4009 IDNAC to extend power and wiring distance even farther and supervisory capacity by up to 139 additional unit loads or 3 A On board IDNet 2 dual loop SLCs with addressable initiating device through two electrically isolated channels for TrueAlarm analog and IDNet communications monitoring and control devices an electrically isolated output channel You can use this with either or unshielded twisted or untwisted single pair wiring and it dual short circuit isolating output loops Battery charger for up to 110 Ah batteries UL or up to 50 Ah batteries 33 Ah maximum in control unit cabinet for 1 bay systems 50 Ah 2 bay systems 2 A programmable function auxiliary output Remote annunciator module support through Remote Unit Interface communications port for either Class B or Class A operation 48 LED panel mount annunciation with 40 Red and 8 Yellow LEDs select models optional LED kits are available to individual LED color to Green or Blue to meet specific site ESS mounted modules include City Connect Module Alarm Relay Module Battery brackets for seismic area protection 1 1 Bay Cabinet 2 1 Bay Cabinet with LED Annunciation 3 2 Bay Cabinet block space modules include Fire Alarm Network Interface Cards NIC for ES Net Peer to Peer fire network communications supports either Class B or Class X Ethernet connectivity options include ES Net NIC and BACpac Ethernet Dual Class A IDNAC Isolator DCAI Dual RS 232 Module for printer or third party interface VESDA Air Aspiration High Level Interface Serial DACT 8 Point Zone or Relay Module 4 Point Auxiliary Relay module with or without Feedback Additional IDNET addressable channels with Autocall remotely located 4098 9757 QuickConnect2 TrueAlarm smoke sensors A4081 Series 110 Ah Battery Chargers 4100 7400 Series Graphic Annunciators A606 9102 Remote LCD Annunciator A100 9400 Series Remote ES Screen Displays A100 9400 Series Remote InfoAlarm Command This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7272 2269 0537 7165 2269 0541 and 7165 2269 0542 for allowable values and or conditions concerning material presented in this document NYC Fire Dept COA 6272 Refer to 6 and 7 for applicable listings at time of publication Additional listings may be applicable contact your local product supplier for the latest status Refer to specific product listings in tables 5 and AC4010 0011 Rev 21 11 2021 Fire Detection with IDNAC Fire Alarm Control Unit and Accessories and A602 Series Status Command Units SCU and Remote Units RCU Annunciators Almost Dirty Agency listings UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service Smoke Control System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UULH UL 2017 Emergency Alarm System Control Units CO detection FSZI Equipment Management QVAX Series fire detection and control units Series fire detection and control units provide leading edge operator and service features for customer applications the mid range addressable fire alarm systems market An onboard port provides fast external system communications to expedite and service activity Dedicated compact flash memory provides secure on site system information storage of job configuration files design variety of functional modules are available to meet specific system Selections facilitate the configuration of control units for Stand Alone or Networked fire control operation description The mounting box provides convenient stud markers for drywall and nail hole knockouts for quicker mounting Smooth box surfaces provide locally cutting conduit entrance holes where required The hinged User Interface panel easily opens for internal access Modules are power limited except as noted Doors include tempered glass inserts and boxes and doors are in platinum or red Basic control unit assemblies include box and door or retainer Cabinet assemblies are rated NEMA 1 and IP 30 Cabinet assembly design is seismic tested and is certified to IBC and standards as well as to ASCE 7 categories A through F requires brackets as detailed on data sheet AC2081 0019 unit hardware Master Controller and ESS are mounted in the upper section the 4010ES cabinet See 1 and 2 bay loading reference diagrams one and two bay loading reference Block Space Option Cards mount to the left of the 4010ES In 2 bay cabinets block space option cards also mount below the ESS 4010ES options The 4010ES City Connect module or the Alarm Relay module mount directly to the ESS These options mutually exclusive battery compartment is located in the bottom of the 4010ES The cabinet allows for up to 33 Ah battery capacity for 1 bay and 50 Ah for 2 bay systems 50 Ah batteries also require the of A100 0650 battery shelf feature summary TrueAlarm individual analog sensing with front panel information and access Dirty TrueAlarm sensor maintenance alerts service and status reports TrueAlarm magnet test indication appears as distinct Test Abnormal on display when in test mode TrueAlarm sensor peak value performance report Install Mode allows grouping of multiple troubles for uninstalled and devices into a single trouble condition Module level ground fault searching assists installation and service by and isolating modules with grounded wiring Recurring Trouble Filtering allows the control unit to recognize and log recurring intermittent troubles such as external ground faults but only sends a single outbound system trouble avoid nuisance communications WALKTEST silent or audible system test performs an automatic self test cycle Addressable Device control ESS provides an IDNet 2 addressable device SLC with two isolated that supervise wiring connections and the individual device status on the SLC With 2 wire IDNet 2 SLCs initiation and control devices such as manual fire alarm stations sensors control relays and sprinkler waterflow switches communicate their identity and status and receive fire alarm control Additional addressable interface modules include circuit conventional IDC zone adapters and interface to other system such as fans dampers and elevator controls 2 Addressable Device operation addressable device on the IDNet communication channel is