Autocall 4010ES Series Addressable Fire Detection and Basic Control Unit Modules and Accessories

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Control Units Fire Detection with IDNAC Control Unit Modules and Accessories ULC CSFM Listed FM NYC Fire Approved with Autocall ES Net fire alarm network system includes Models available with Color ES Touch Screen Display or Monochrome 2 x 40 Character Display Capacity for up to 1000 addressable IDNet points up to 127 VESDA Aspiration Systems interface points and up to 254 addressable appliances with up to 2000 points of Annunciation and up 20 internal and external card addresses CPU assembly includes dedicated compact flash memory for on site information storage and convenient Ethernet service port an Enhanced System Supply ESS that provides power battery charging 6 A output Dual 3 A on board IDNAC Signaling Line Circuits SLCs provide power delivery to addressable notification appliances With an IDNAC SLC a constant 29 VDC source voltage is maintained alarm even during battery operation allowing strobes to at higher voltage with lower current and ensuring a consistent draw and voltage drop margin under both primary power and battery standby Efficiencies include lower strobe currents wiring distances up to two three times farther than with conventional notification support for appliances per IDNAC SLC ability to use smaller gauge wiring providing installation and maintenance savings with high assurance appliances that operate during normal system testing will operate worst case alarm conditions IDNAC SLCs are compatible with both TrueAlert ES and TrueAlert notification appliances and remote 4009 IDNAC to extend power and wiring distance even farther and supervisory capacity by up to 139 additional unit loads or 3 A Addressable initiating device control is provided by on board IDNet dual loop SLCs that provide two electrically isolated channels that TrueAlarm analog sensors and IDNet communications and control devices with an electrically isolated output allowing use with either shielded or unshielded twisted or single pair wiring and providing dual short circuit isolating loops Battery charger for up to 110 Ah batteries UL or up to 50 Ah batteries 33 Ah max in control unit cabinet for 1 Bay Systems 50Ah for 2 systems 2 A programmable function auxiliary output Remote annunciator module support via RUI communications port A or B operation 48 LED panel mount annunciation provides 40 Red and 8 Yellow LEDs select models optional LED kits are available to individual LED color to Green or Blue to meet specific site 1 2 Bay Cabinet 2 1 Bay Cabinet with LED Annunciation 3 1 Bay Cabinet ESS mounted modules door mounted modules and options include City Connect Module Alarm Relay Module Battery brackets for seismic area protection block space modules include Fire alarm network interface cards NIC for ES Net peer to peer fire network communications supports either Class B or Class X Ethernet connectivity options include Building Network Interface Card and BACpac Ethernet Portal Dual Class A IDNAC Isolator DCAI Dual RS 232 Module for printer PC annunciator or third party VESDA Air Aspiration High Level Interface Serial DACT 8 Point Zone Relay Module 4 Point Auxiliary Relay Module with or without Feedback Additional IDNet addressable channels with Autocall remotely located 4098 9757 QuickConnect2 TrueAlarm smoke sensors A4081 Series 110 Ah Battery Chargers 4009 IDNet NAC Extenders and IDNAC Repeaters 4100 7400 Series Graphic Annunciators A4606 9102 Remote LCD Annunciator A100 9400 Series Remote ES Screen Displays A100 9400 Series Remote InfoAlarm Command and A602 Series Status Command Units SCU and Remote Units RCU Annunciators IP communicator compatibility This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7272 2269 0537 7165 2269 0541 and 7165 2269 0542 for allowable values and or conditions concerning material presented in this document NYC Fire Dept COA 6272 Refer to 1 and 2 for applicable listings at time of publication Additional listings may be applicable contact your local Autocall product supplier for the latest status For specific product listings refer to 4 and 5 AC4010 0012 Rev 17 11 2021 Fire Detection with IDNAC Control Unit Modules and Accessories Agency listings UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service Smoke Control System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UULH UL 2017 Emergency Alarm System Control Units CO detection FSZI Equipment Management QVAX ULC S527 Control Units System Fire Alarm UOJZ7 Control Unit System Fire Alarm UOXX7 Control Units Releasing Service SYZV7 ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm System Units APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 Series Fire Detection and Control Units Series Fire Detection and Control Units provide leading edge operator and service features for customer applications the mid range addressable fire alarm systems market An onboard port provides fast external system communications to expedite and service activity Dedicated compact flash memory provides secure on site system information storage of job configuration files design variety of functional modules are available to meet specific system Selections allow control units to be configured for either or Networked fire control operation Description Mounting box provides convenient stud markers for drywall thickness nail hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance exactly where required The hinged User Interface panel easily opens for internal access Modules are power limited except as noted Doors include tempered glass inserts boxes and doors are available in Box and door retainer assemblies are included with Basic Control Unit or red Cabinet assemblies are rated NEMA 1 and IP 30 Cabinet assembly design is seismic tested and is certified to IBC and standards as well as to ASCE 7 categories A through F requires brackets as detailed on data sheet AC2081 0019 Unit Hardware The Master Controller and Enhanced System Supply ESS are mounted the upper section of the 4010ES cabinet refer to Cabinet One and Bay Loading Reference 4010ES Block Space Option Cards mount to the left of the 4010ES In 2 bay cabinets block space option cards also mount below the ESS 4010ES Options The 4010ES City Connect module or the optional Alarm Relay module directly to the ESS These options are mutually exclusive The battery compartment is located in the bottom of the 4010ES The cabinet allows for up to 33 Ah battery capacity for 1 bay and 50 Ah for 2 bay systems 50 Ah batteries also require the of A100 0650 battery shelf Feature Summary TrueAlarm individual analog sensing with front panel information and access Dirty TrueAlarm sensor maintenance alerts service and status including almost dirty TrueAlarm magnet test indication appears as distinct test abnormal on display when in test mode TrueAlarm sensor peak value performance report Install Mode allows grouping of multiple troubles for uninstalled and devices into a single trouble condition typical with future expansion with future equipment and devices grouped into single trouble operators can more clearly identify events from the and occupied areas Module level ground fault searching assists installation and service by and isolating modules with grounded wiring Recurring Trouble Filtering allows the control unit to recognize and log recurring intermittent troubles such as external wiring faults but only sends a single outbound system trouble to nuisance

Related Files