Autocall 4100ES Network Display Unit (NDU) Annunciator Panels with EPS Power Supplies for ES Net

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed ES Network ES Net Network Display Unit NDU Annunciator Panels with EPS Power Supplies for ES Display Unit NDU provides annunciation for up to network points The basic NDU is a special purpose master controller that includes an Net network interface card An NDU with a voice command center VCC mounted in the same provides an additional separate network node within the cabinet for control of network level emergency voice alarm equipment master controller equipment top bay Master controller assembly with operator interface 4100ES CPU with dual configuration programs convenient service port and capacity for up to 12,000 points System power supply SPS and charger 9 A total with on board auxiliary output Operator interface that is conveniently color coded with raised providing high confidence feedback Available with InfoAlarm command center expanded content user refer to data sheet AC4100 0101 Construction that is optimized for easy installation upgrade and Glass door ordered separately provides view of available operator visible behind locked door addressable interfaces include Remote annunciator module support via RUI remote unit interface port field installed option modules include DACT and city connection RS 232 ports for printers or maintenance terminals Alarm relays and expansion power supplies Battery brackets for seismic area protection equipment second expansion bay VCC includes enhanced power supply EPS and battery charger 9 A with on board IDNAC SLCs signaling line circuit for addressable control electrically isolated IDNet 2 addressable device module with dual short circuit isolating output loops and function auxiliary output For additional information concerning EPS power supplies and their features and on IDNet 2 communications modules refer 4100ES data sheet AC4100 0100 and refer to additional related data sheet list Voice control options are similar to a networked fire alarm control with an extensive list of modules available for initiating and user interface 4100ES NDU with VCC for ES Net is a network level annunciator and system point controller with Network voice control equipment provides alphanumeric annunciation for up to 12,000 Network points point lists and can be programmed to function as the network controller for Alarm Silence Trouble Acknowledge and System 1 one line diagram showing an NDU with VCC information UL 864 Fire Detection and Control UOJZ Releasing Device Service UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 Net Network Overview connected to other ES Net network nodes individual fire alarm panels become components of a distributed intelligence system This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 2269 0542 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status See product for models that are UL listed Rev 5 01 2020 documentfirealarmresources com Network Display Unit NDU Annunciator Panels with EPS Power Supplies for ES Net with VCC internal module bay reference panel that directly connects to the network is called a network and is capable of performing individual supervision and control its locally connected devices but has the ability to inform the 4100ES as well as other network control panels of point status and panel This allows system information to reach the proper location appropriate system response 4100ES NDUs separately packaged can be connected to a to duplicate common information at separate locations or selected information by type such as troubles alarms control etc module bay description NDU master controller bay top includes a special purpose power supply with battery charger SPS the master controller an ES network interface card and operator interface equipment to that used on the standard fire alarm control modules Slots 1 2 are available for single slot panel mounted modules VCC includes an expansion bay with separate master controller ES network interface card and an EPS power supply with IDNet 2 This results in two separate network nodes residing within the cabinet the VCC bay a dual PDI connection is available for either a dual slot or one or two block modules Optional LED switch modules can be mounted For 2 bay cabinets the VCC mounts in bay 2 For 3 bay as shown to the right the VCC mounts in the second expansion bay 3 battery compartment bottom accepts two batteries up to 50 to be mounted within the cabinet without interfering with module to the NDU with VCC internal module bay reference illustration for three bay cabinet module location availability Modules are power limited unless specifically noted otherwise Enclosure are available for one two or three bay sizes or for cabinet mounting Additional cabinets can be mounted close nippled for module NEMA 1 IP30 boxes doors with tempered glass inserts and dress are available in platinum or red ordered separately Refer to data sheet AC4100 0037 for enclosure details feature summary Selectable service override allows authorized operators to clear alarm during system reset even if status has gone to trouble reset occurred Duplicate address error detection Convenient PC programming using a Microsoft Windows user interface program 2 with VCC Internal Module Bay Reference layout is determined by specific system requirements module details top bay master controller motherboard includes a controller master controller motherboard ES Net NIC SPS power supply The master controller mounts in slot 4 of a two slot motherboard 3 and 4 of the master controller bay and provides one RUI channel Class B or Class A available at slot 4 An ES network interface card is mounted in slot 3 The NDU bay RUI communications output configurable for isolated un isolated operation supports up to 31 devices per master at up to 2500 ft 762 m for single run or 10,000 ft 3048 m if wiring is Class B and T tapped If more distance is required up four total RUI channels are supported per master controller up to A100 1291 RUI expansion modules may be added A100 1291 un isolated RUI communications Both the NDU master controller RUI output and RUI expansion support the following remote LCD annunciators A4603 9100 LCD annunciators and A100 9400 series remote InfoAlarm centers System power supply SPS is rated for 9 A total includes battery one 2 A aux power output selectable for detector reset door or coded output operation and expansion slot for one city 2 Rev 5 01 2020 documentfirealarmresources com Network Display Unit NDU Annunciator Panels with EPS Power Supplies for ES Net interface Status Information the locking door closed the glass window allows viewing of the status LEDs and available operator switches Features include two line by 40 character wide viewing angle super twist LCD with LEDs and switches as shown in the illustration below indicators describe the general category of activity being displayed the LCD providing more detail For the authorized user unlocking door provides access to the control switches and allows further by scrolling the display for additional detail interface detail reference 3 interface detail reference A100 6031 or A100 6032 or alarm supv tbl relay A100 6033 see data sheet AC4100 0100 for details Outputs are power limited except for the battery charger SPS IDNet channel NACs and aux relay are disabled in NDU bay expansion bay includes a master controller master motherboard ES Net NIC and EPS power supply with 2 module The master control

Related Files