Autocall 4100ES Network Display Units with SPS Power Supplies for ES Net
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-4100es-network-display-units-with-sps-power-supplies-for-es-net-8350741269.pdf |
---|---|
Type | |
Size | 5.37 MB |
Downloads |
Text Preview
UL ULC CSFM Listed ES Network ES Net Network Display Units with SPS Power Supplies for ES Net Display Unit NDU provides annunciation for up to ES Net network points The basic NDU is a special purpose master controller that includes an Net network interface card Combining a basic NDU with a Voice Command Center VCC provides additional separate Network node within the same cabinet for of Network level Emergency Voice Alarm Communications Controller top bay Master controller assembly with operator interface Enhanced CPU with dual configuration programs convenient service access and capacity for up to 12,000 points System power supply SPS and charger 9 A total with on board auxiliary output Operator interface that is conveniently color coded with raised providing high confidence feedback Available with InfoAlarm Command Center expanded content user refer to data sheet AC4100 0045 Construction that is optimized for easy installation upgrade and Glass door ordered separately provides view of available operator visible behind locked door addressable interfaces include Remote annunciator module support via RUI remote unit interface port field installed option modules include DACT and City Connection RS 232 ports for printers or maintenance terminals Alarm relays and expansion power supplies Battery brackets for seismic area protection NDU with VCC Optional features are similar to a networked fire alarm control panel an extensive list of modules are available for initiating notification user interface information UL 864 Fire Detection and Control UOJZ Releasing Device Service UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 1 Net Network One Line Showing an NDU with VCC 4100ES Network Display Unit for ES Net is a network level and manual system point controller It provides annunciation for up to 12,000 Network points and or lists and can be programmed to function as the network master for Alarm Silence Trouble Acknowledge and System Reset Net Network Overview connected to other ES Net nodes individual fire alarm control become components of a distributed intelligence system Each that directly connects to the network is called a network node is capable of performing individual supervision and control on locally connected devices but has the ability to inform the 4100ES as well as other network control panels of point status and panel This allows system information to reach the proper location appropriate system response This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7165 2269 0542 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest See product specifications for models that are UL listed Rev 6 3 2020 documentfirealarmresources com Network Display Units with SPS Power Supplies for ES Net 4100ES NDUs separately packaged can be connected to a to duplicate common information at separate locations or selected information by type such as troubles alarms control etc with VCC internal module bay reference module details top bay master controller motherboard includes a controller master controller motherboard ES Net NIC SPS power supply The master controller mounts in slot 4 of a two slot motherboard 3 and 4 of the master controller bay and provides one RUI channel Class B or Class A available at slot 4 An ES network interface card is mounted in slot 3 The NDU bay RUI communications output configurable for isolated un isolated operation supports up to 31 devices per master at up to 2500 ft 762 m for single run or 10,000 ft 3048 m if wiring is Class B and T tapped If more distance is required up four total RUI channels are supported per master controller up to A100 1291 RUI expansion modules may be added A100 1291 un isolated RUI communications See note below Both the NDU master controller RUI output and RUI expansion support the following remote LCD annunciators A4603 9100 LCD annunciators and A100 9400 series remote InfoAlarm centers System power supply SPS is rated for 9 A total includes battery one 2 A aux power output selectable for detector reset door or coded output operation and expansion slot for one city A100 6031 or A100 6032 or alarm supv tbl relay A100 6033 See data sheet AC4100 0100 for details Outputs are power limited except for the battery charger SPS IDNet channel NACs and aux relay are disabled in NDU bay expansion bay includes a master controller master motherboard ES Net NIC and SPS power supply with communications channel The master controller mounts in slot 4 of a two slot motherboard 3 and 4 of the master controller bay and provides one RUI channel Class B or Class A available at slot 4 An ES network interface card is mounted in Slot 3 The VCC bay RUI communications output configurable for isolated or operation supports up to 31 devices per master controller up to 2500 ft 762 m for single run or 10,000 ft 3048 m total wiring is Class B and T tapped If more distance is required up to total RUI channels are supported per master controller up to A100 1291 RUI expansion modules may be added A100 1291 un isolated RUI communications Both the VCC master controller RUI output and RUI expansion are compatible with the following equipment miniplex A4603 9100 series LCD annunciators A100 9400 remote InfoAlarm command centers 4100 series 24 I O and modules and A602 series status command units SCU command units RCU and graphic I O modules A602 series requires un isolated output System power supply SPS is rated for 9 A total includes charger auxiliary power auxiliary relay on board IDNet channel for 250 points three on board NACs and for either an optional city connect module or an optional relay module see data sheet AC4100 0031 for details Battery charger is dual rate temperature compensated and charges to 50 Ah sealed lead acid batteries mounted in the battery 33 Ah for single bay cabinets also is UL listed for up to 110 Ah batteries mounted in an external cabinet see sheet AC2081 0012 for details Battery and charger monitoring includes battery charger status and or depleted battery conditions status information provided to the controller includes analog values for battery voltage charger and current actual system voltage and current and individual currents Low battery cutout is selectable for each SPS power supply Canadian 2 with VCC internal module bay reference layout is determined by specific system requirements module bay description NDU master controller bay top includes a special purpose power supply with battery charger SPS the master controller an ES Net network interface card NIC and operator interface similar to that used on the standard fire alarm control Slots 1 and 2 are available for single slot panel mounted VCC includes an expansion bay with separate master controller ES Net NIC and a standard SPS power supply This results in two network nodes residing within the same cabinet the VCC bay typically the second expansion bay slots 1 and 2 are for single slot panel mounted modules Optional LED switch can also be mounted here battery compartment bottom accepts two batteries up to 50 to be mounted within the cabinet without interfering with module to the NDU with VCC internal module bay reference illustration for three bay cabinet module location 2 Rev 6 3 2020 documentfirealarmresources com Network Display Units with SPS Power Supplies for ES Net mounting Additional cabinets can be mounted close nippled for module 3 Bay Module Loading Referenc