Autocall 4100ES Redundant CPU Fire Alarm Control Units

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Alarm Systems Redundant CPU Fire Alarm Control Units ULC and CSFM Listed FM NYC Fire Dept Redundant CPU Controller Card switches system operation to a back CPU and Power Converter board in the event of CPU or Power failure This is achieved through the use of two CPU bays a and a secondary A primary CPU bay contains the primary CPU the additional controller cards necessary to switch to a secondary if a trouble occurs The primary system power supply SPS is in the primary CPU bay secondary CPU bay contains the secondary CPU and a secondary Figure 3 shows a typical layout of the components within a CPU Fire Alarm Control Unit cabinet A100 9121 model includes two additional redundant 2 x 40 user assemblies one primary and one backup The A100 9122 A100 9222 models include a single InfoAlarm large screen display interface redundancy is provided for the CPU and Power Supply 2 Redundant CPU 2 x 40 Display with Three Bay Cabinet CPU Features for hot standby redundant CPU provides redundancy and automatic backup in case of main CPU or power supply failure If there is a failure in the CPU or system power supply all communications and power for control unit operation automatically switch to the redundant CPU power supply redundant power supply dedicated system power supply SPS powers the the redundant CPU two bay assembly primary CPU and power supply and the backup CPU and power both require a separate bay of space in the control unit with standard 2x40 user interface or InfoAlarm user 1 Redundant CPU InfoAlarm with Three Bay Cabinet Additional listings may be applicable contact your local Autocall product supplier for the latest status Rev 1 06 2021 Redundant CPU Fire Alarm Control Units Information UL 864 Fire Detection and Control UOJZ Smoke Control Service UUKL Releasing Device Service SYZV UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm System Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Device Service SYZV7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 Diagram 3 Primary and Secondary Bay reference diagram CPU Product Selection CPU with 2x40 Display and English Keys CPU with Display and Raised Keys CPU with Display Flat Keys Slide in Labels for Key Descriptions to VAC Hz 1 4100ES Redundant CPU Fire Alarm Control Units mA mA mA mA VAC Hz CPU Fire Alarm Control Unit with two 2x40 operator interfaces two CPU cards and two 9 A SPS supplies in a two bay assembly one of each for and backup Active SPS battery charger in Bay only External RUI connections require A100 1291 RUI modules CPU Fire Alarm Control Unit with one user interface two CPU cards and two 9 A power supplies in a two bay assembly Active SPS charger in Bay 1 only External RUI connections A100 1291 RUI expansion modules ULC CSFM Fire ULC CSFM Fire FM NYC Dept Do not use circuit connections on primary and secondary SPS power supplies Not compatible with ES Net network panels 2 Rev 1 06 2021 Redundant CPU Fire Alarm Control Units 2 InfoAlarm Command Center Memory Option may be required to be ordered separately refer to description details Memory Expansion Module included with NDU systems required for all InfoAlarm Command Centers connected to a unit if are using 2 byte character fonts 6 Meg module mounts on rear of display board 3 Remote InfoAlarm Command Center Control Assembly with Cabinet for Surface Mounting Number Cabinet Color and FM InfoAlarm Command Center with cabinet for surface mounting mounting box and door assembly with glass insert uses RUI or RUI requires external 24 VDC system voltage flat key user interface slide in labels refer to Figure 4 and Figure 5 and Installation Instructions Remote Display Assembly Installation Instructions for details InfoAlarm Command Center Front View 4 Remote InfoAlarm Command Center Front View 3 Rev 1 06 2021 InfoAlarm Command Center Mounting Reference Redundant CPU Fire Alarm Control Units Bring wiring through back of box do not use cabinet bottom refer to installation instructions shipped with assembly 5 Remote InfoAlarm Command Center Mounting Reference 4 Rev 1 06 2021 Power Supplies SPS Input Power 4 Redundant CPU System Power Supply Specifications Redundant CPU Fire Alarm Control Units VAC Models to 240 VAC Models A maximum 102 to 132 VAC 60 Hz A maximum 204 to 264 VAC 50 60 Hz taps for 220 230 240 VAC switches to battery backup during AC failure or brownout conditions A total output power supply Must support powering in the same bay available for IDNet NAC or Power circuit connections primary and secondary SPS supplies listed for battery charging of 6.2 Ah up to 110 Ah batteries larger than 50 require a remote battery cabinet compensated dual rate recharges depleted batteries within 48 per UL Standard 864 to 120 0 to 49 to 93 RH non condensing 90 32 maximum Power Supply Output Ratings for Redundant CPU nominal 28 VDC AC 24 VDC on battery backup Charger Ratings for SPS sealed batteries capacity range characteristics and Temperature Humidity Reference Polarizer Type Adjustment Operation Options 5 InfoAlarm General Display Specifications Matrix Size Display Area x 240 in W x 3.4 in H 115 mm x 86 mm includes header footer and softkey area 5.66 diagonal measurement 144 mm to 854 characters total using standard ASCII character font one quarter of standard VGA Video Graphics Array display with rear backlight adjustment is located on the controller module LEDs with intensity adjustment and selectable AC power fail operation intensity is located on the controller module continuously Off with AC power fail until a switch is pushed selectable timeout switch activity 6 Control Panel Mounted InfoAlarm Command Center Current Requirements Controllers A100 9114 A100 9212 CPUs A100 9122 A100 9222 mA 24 VDC mA 24 VDC backlight and tone alert on mA 24 VDC mA 24 VDC backlight and tone alert on 7 Remote Annunciators with InfoAlarm Command Center Powered from Control Panel panel currents are Add external loading according system requirements Details Stand Alone Cabinet Models Capacity RUI Output Requirements Device List to 33 VDC 24 VDC nominal system supplied requires separate wiring mA 24 VDC mA 24 VDC backlight and tone alert on Remote InfoAlarm Command Center Mounting Reference reference illustration Remote Unit Interface isolated or un isolated external annunciator line SLC signaling line circuit Class B or Class A operation to 31 total remote RUI devices including up to 10 InfoAlarm Command Center InfoAlarm Command Center Remote Annunciators MINIPLEX Transponders LCD Annunciator A602 9101 Status Command Unit SCU and A602 9102 Command Unit RCU refer to data sheet for additional 4100ES RUI 4602 series annunciators require un isolated communications twisted shielded pair 18 AWG 0.82 mm2 to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power dedicated earth ground connection to the electrical box is required for proper ESD EMI protection wire in accordance with NFPA 70 National Electrical Code Article 5 Rev 1 06 2021 Redundant CPU Fire Alarm Control Units Temperature Humidity to 120

Related Files