Autocall A4090-5250 Loop Powered Multiple I O Module with Three Inputs and Two Outputs
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-a4090-5250-loop-powered-multiple-i-o-module-with-three-inputs-and-two-outputs-1425796803.pdf |
---|---|
Type | |
Size | 2.24 MB |
Downloads |
Text Preview
UL Listed Technology Addressable Devices Loop Powered Multiple I O Module with Three Inputs and Two Outputs Technology addressable multiple input output module MX loop powered separate voltage is not required Three supervised Class B independent inputs for monitoring either or N C contacts You can select inputs as Style B for multiple input contacts short is an input open is a trouble or as Style C for a single current limited short or open is a trouble Outputs are two separate Form C dry volt free latching relay contacts 2 A 24 VDC Monitors relays for a stuck condition causing a relay fault Individually monitors and controls inputs and outputs through system You can easily program the address with the 801AP Programming Tool Status LED illuminates when any of the three inputs is active in the state the LED blinks to indicate polling from the MX Control You can select blink on poll when programming the control Mounts in D800 IP55 housing using this cover you can view the status LED UL listed to Standard 864 device You can program five sub points for this module three sub points for and two sub points for outputs Use with the Autocall 4100ES and 4010ES fire alarm control units with an MX Loop Module Refer to data sheet AC4100 0059 for MX Loop Module details This module is compatible with DIN Rail mounting not UL listed 1 Multiple I O Module 2 Multiple I O Module a D800 housing without a cover Multiple I O Modules Multiple I O Modules use MX Technology to provide an input output module with flexible monitoring of three and control of two outputs to satisfy a variety of applications are individually addressable and communicate with an MX Module in the host fire alarm control unit include monitoring fire contacts such as extinguishing control ventilation control and fire door control Inputs are and the Form C output contacts are dry volt free suitable a variety of applications Additional listings may be applicable contact your local product supplier for the latest status Rev 1 10 2020 Loop Powered Multiple I O Module with Three Inputs and Two Outputs mm H x 110 mm W x 18 mm D 27 32 in x 4 11 32 in x 23 32 in mm H x 140 mm W x 70 mm D 3 4 in x 5 1 2 in x 2 3 4 in Selection 1 Product selection I O Module three Class B inputs and two Form C relay outputs Ancillary housing IP55 rated provides viewing port for status LED Mounting Kit not UL listed 2 Accessories MX Service Tool Ancillary Program Lead spare Service Tool Accessory Kit of 10 spare pins for ancillary programming lead Loop current contact ratings resistance to monitored mA in standby mA in alarm A 24 VDC ohm maximum 3 Specifications options connections temperature instructions or multiple input N O contact Style B with open circuit trouble fault and short circuit input active 300 ohm end of line resistor or N C single input Style C contact with open circuit or short circuit trouble fault and current limited input active 300 ohm end of line resistor and 150 ohm resistor wired in series with contact common refer to installation instructions for details blocks for wire size 0.5 mm to 2.5 mm2 20 AWG to 14 AWG to 120 0 to 49 to 93 RH non condensing 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 1 10 2020