Autocall A4090-9119 Relay IAM (Individual Addressable Module) with Unsupervised Input
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-a4090-9119-relay-iam-individual-addressable-module-with-unsupervised-input-7210438956.pdf |
---|---|
Type | |
Size | 922.32 KB |
Downloads |
Text Preview
Datasheet Peripherals Relay IAM Individual Addressable Module with Unsupervised Input ULC CSFM Listed FM point operation provides an unsupervised input and a relay in a single package using only one address Typical applications are for fan control with single unsupervised status monitoring For use with Autocall 4007ES 4010ES 4100ES Fire Alarm Control providing IDNet communications details Input provides unsupervised monitoring of normally open dry contacts Total wiring distance to supervised contacts is up to 500 ft 152 m for wiring applications Low power latching relay design allows IDNet communications to both data and module power Relay is set to OFF on initial power up and upon loss of IDNet ratings Form C relay output is rated 2 A 30 VDC and 0.5 A 120 VAC sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Screw terminals for wiring connections Optional covers are available to allow LED to be viewed after Listed to Standard 864 Address Dual Point Module A4090 9119 Relay IAM allows a compatible Autocall fire alarm panel IDNet communications channel to monitor an input contact closure with one point and control an relay with the other point both from a compact module a single address Module power is supplied from the IDNet channel eliminating the need for separate power Device Description input circuit and relay operation are controlled independently and be disabled separately Point association is determined at the panel At the host panel display the device address is designated a single hardware location such as 1 1 The individual points are sub points and are layered underneath such as 1 1 1 and 1 Relay IAM with Unsupervised shown approximately 1 2 size Selection Adapter and Trim Plates IAM with Unsupervised Input plate to fit 4 11 16 119 mm square electrical semi flush box surface box trim plate with LED viewing includes mounting screws steel Applications Package smoke control applications this module provides an efficient for fan control with single status feedback The monitor point feedback from a single set of unsupervised contacts such as a switch or pressure switch allowing the host panel to track the result the requested relay control operation Applications monitor and control points can be applied for a variety of associated independent operations Flexible programming abilities at the host can provide the association logic required for a wide variety of fire utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0505 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 8 03 2021 Relay IAM Individual Addressable Module with Unsupervised Input Reference 2 information For Fire Alarm applications locate loads within 3 ft 1 m of contacts Power Limited Contact Ratings A 30 VDC resistive loads A 30 VDC inductive loads Non Power Limited Contact Ratings A 120 VAC resistive loads A 120 VAC inductive loads to specifications for additional information Refer to Installation Instructions 574 875AC for detailed installation information A4090 9119 Relay IAM with Input is illustrated Wiring Distances Up to 2500 ft 762 m from host control panel Up to 10,000 ft 3048 m total wiring distance including T taps Refer to Installation Instructions 574 875AC for detailed installation information A4090 9119 Relay IAM with Input is illustrated 2 Rev 8 03 2021 Relay IAM Individual Addressable Module with Unsupervised Input Allocation Requirements Connections Type Point Usage per Panel Points Usage Contact Ratings C SPDT not rated for switching 1 Electrical communications one address one unit load power supplied from IDNet communications for relay to 3 1 for relay 1 for input 1 for trouble for points mapped to the Fire Alarm Network open dry contacts to 500 ft 152 m total distance from Relay IAM indoor wiring applications only terminals for input and output wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive listed fire alarm supply Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed 120 VAC loads require RC networks or varistors depending on device type Refer to Installation Instructions 574 875AC for additional information Wiring Distance Reference Range to 2500 ft 762 m from the fire alarm control panel to 10,000 ft 3048 m total Class B wiring distance including T Taps with A2081 9044 Overvoltage Protectors 2 Mechanical H x 4 1 8 W x 1 3 8 D 105 mm x 105 mm x 35 mm thermoplastic housing on metal mounting plate to 120 F 0 to 49 C indoor operation only to 90 RH at 90 F 32 C 3 Rev 8 03 2021 Information Relay IAM Individual Addressable Module with Unsupervised Input A4090 9119 Relay IAM with unsupervised feedback is shown in Figure 3 3 reference double gang blank cover plate 4 Trim Plates for Visible LED The following parts are illustrated in Figure 4 A4090 9801 Trim plate for semi flush mounted box A4090 9802 Trim plate for surface mounted box 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 8 03 2021