Autocall A4090-9120 Six Point Module with Four T-Sense Inputs and Two Relay Outputs

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Peripherals Six Point Module with Four T Sense Inputs and Two Relay Outputs ULC CSFM Listed FM point operation provides four supervised multi state inputs two relay outputs in a single package using only one For use with Autocall 4007ES 4010ES or 4100ES Fire Alarm Control providing IDNet communications Typical applications include fan motor control centers monitoring pump motor running status low pressure fuel warnings and for dual damper position feedback monitoring details Four inputs provide supervised monitoring of normally open contacts Status conditions are Normal Open Circuit trouble condition Current position input 1 and Short position input 2 Total wiring distance to supervised contacts is up to 500 ft 152 m for wiring applications 120 VAC resistive ratings Two relay outputs with Form C contacts rated 2 A 30 VDC and 0.5 A construction Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after Screw terminals for wiring connections Listed to Standard 864 Address Six Point Module A4090 9120 Six Point Module allows a compatible Autocall fire control panel IDNet communications channel to monitor four T input circuits and control two output relays from a single compact requiring a single address Power is supplied by a 24 VDC to a listed fire alarm power supply Device Description input circuits and output relay operation are controlled and may be disabled separately Point association is at the host panel At the host panel display the device is designated as a single hardware location such as 1 1 Each the six individual points appear as sub points and are layered such as 1 1 1 1 1 2 1 1 3 1 Six Point Module Operation Input of the four input circuits monitors for continuity to an end of line and can differentiate between a short circuit contact closure and current limited contact closure State Operation is when all contacts are open and there is continuity to the end resistor Open is when continuity does not exist to the end of resistor causing a Trouble condition Short indicates that a contact closed that is directly connected to the input circuit and Current indicates that a contact has closed beyond a series connected limiting resistor This operation allows differentiation between different contact types due to their wiring location and reporting as single IDNet addressable point to the fire alarm control panel Applications Package smoke control applications this module provides an efficient for fan damper control with position feedback Monitor points be connected to two separate status indicator switches per circuit the host panel to track fan damper status with respect to the fan control operation Applications monitor and control points can be applied for a variety of associated independent operations Flexible programming abilities at the host can provide the association logic required for a wide variety of fire utility operations This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0505 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 8 03 2021 Six Point Module with Four T Sense Inputs and Two Relay Outputs Selection 1 Product Selection Point Module semi flush mounted box surface mounted box trim plate with LED viewing window includes mounting screws galvanized steel No 2 End of Line Resistor Harnesses ordered separately as required k 1 2 W Standard end of line resistor harness for N O contact supervision k 1 2 W k 1 2 W for current limited monitoring applications refer to Wiring Reference Input Operating Modes 3 Common Circuit Status Modes Status open discontinuity 4 Damper Position Monitoring Status Modes Status A closed B closed 5 Waterflow and Tamper Switch Monitoring Status Modes Status switch closed switch closed Display Panel Display Closed Open Display Alarm Status circuit Status Limited Status Limited 2 Rev 8 03 2021 Reference Six Point Module with Four T Sense Inputs and Two Relay Outputs 2 information Fire Alarm applications locate loads within 3 ft 1 m of contacts Limited Contact Ratings A 30 VDC resistive loads A 30 VDC inductive loads Limited Contact Ratings A 120 VAC resistive loads A 120 VAC inductive loads to specifications for additional information Refer to Installation Instructions 574 876AC for detailed installation information A4090 9120 Six Point Model is illustrated in Figure 2 Wiring Distances Up to 2500 ft 762 m from host control panel Up to 10,000 ft 3048 m total wiring distance including T taps 3 Rev 8 03 2021 Information Six Point Module with Four T Sense Inputs and Two Relay Outputs A4090 9120 Six point module is shown in Figure 3 3 Reference Double Gang Blank Cover Plate 4 Trim Plates for Visible LED The following products are illustrated in Figure 4 A4090 9801 Trim plate for semi flush mounted box A4090 9802 Trim plate for surface mounted box 4 Rev 8 03 2021 Six Point Module with Four T Sense Inputs and Two Relay Outputs Power Allocation Requirements Supervision Resistors Connections Type Point Usage per Panel Points Usage Contact Ratings C SPDT not rated for switching 6 Electrical communications one address to 32 VDC nominal 24 VDC mA maximum 24 VDC from listed fire alarm power supply 1 per relay 1 per input to 7 1 per relay 1 per input 1 for trouble for points mapped to the Fire Alarm Network open dry contacts to 500 ft 152 m total distance from Six Point Module indoor wiring applications only required per T sense input refer to page 2 and to Installation Instructions 574 876AC for information and wiring detail terminals for input and output wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 A 30 VDC resistive A 30 VDC inductive A 120 VAC resistive A 120 VAC inductive listed fire alarm supply Provide circuit fusing and transient suppression as required per application DC inductive loads can typically be diode suppressed 120 VAC loads require RC networks or varistors depending on device type Refer to Installation Instructions 574 876AC for additional information Wiring Distance Reference Bracket Range Instructions to 2500 ft 762 m from the fire alarm control panel to 10,000 ft 3048 m total Class B wiring distance including T Taps with A2081 9044 Overvoltage Protectors 7 Mechanical H x 4 1 8 W x 1 3 8 D 105 mm x 105 mm x 35 mm sheet metal to 120 F 0 to 49 C indoor operation only to 90 RH at 90 F 32 C 5 Rev 8 03 2021 Six Point Module with Four T Sense Inputs and Two Relay Outputs 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 8 03 2021

Related Files